Anne Cotten

Anne Cotten

Auto-generated profile, based on publicly available information

Anne Cotten

Department of Skeletal Radiology, Roger Salengro Hospital, CHRU of Lille, Lille Cedex, France

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2007 in European Radiology
Verified
Journal Article
Closed access
PDF file
JBJean-François Budzik
Jean-François Budzik
VTV. Le Thuc
V. Le Thuc
XDX. Demondion
X. Demondion
MMM. Morel
M. Morel
DCD. Chechin
D. Chechin
ACA. Cotten
A. Cotten

1 January 2011 in Radiology
Verified
Journal Article
Closed access
CCClarissa Canella
Clarissa Canella
PPPeggy Philippe
Peggy Philippe
VPVittorio Pansini
Vittorio Pansini
JSJulia Salleron
Julia Salleron
RFRené-Marc Flipo
René-Marc Flipo
ACAnne Cotten
Anne Cotten
To compare tomosynthesis with radiography for the detection of hand and wrist bone erosions in patients with rheumatoid arthritis (RA), using multidetector computed tomography (CT) as the reference method. The study was approved by the local ethics committee, and written consent was obtained from all patients. From December 2008 to April 2009, 30 consecutive patients with RA were included in this prospective study. They underwent radiography, tomosynthesis, and CT of the most symptomatic hand and wrist on the same day. Two radiologists and one rheumatologist independently read images from the three imaging modalities. A total of 232 erosions were detected with CT, while 199 and 140 erosions, respectively, were detected with tomosynthesis and radiography. More erosions were revealed with CT than with tomosynthesis and radiography (P < .0001); significantly more erosions were shown with tomosynthesis than with radiography (P < .0001). With CT as the reference method for bone erosions, the overall sensitivity, specificity, and accuracy of tomosynthesis were, respectively, 77.6%, 89.9%, and 83.1%. The corresponding values for radiography were 53.9%, 92%, and 70.9%. The sensitivity of each reader increased by roughly 20% with use of tomosynthesis. The depiction of bone erosions of the hands and wrists is significantly greater with tomosynthesis than with radiography.

1 August 2003 in European Radiology
Verified
Journal Article
Closed access
PDF file
EDE. M. Delfaut
E. M. Delfaut
XDX. Demondion
X. Demondion
NBN. Boutry
N. Boutry
HCH. Cotten
H. Cotten
HMH. Mestdagh
H. Mestdagh
ACA. Cotten
A. Cotten

1 April 2003
Verified
Journal Article
Closed access
NBNathalie Boutry
Nathalie Boutry
ALAnne Lardé
Anne Lardé
FLFranck Lapègue
Franck Lapègue
ESElizabeth Solau-Gervais
Elizabeth Solau-Gervais
RFRené-Marc Flipo
René-Marc Flipo
ACAnne Cotten
Anne Cotten

1 December 2003 in European Radiology
Verified
Journal Article
Closed access
PDF file
EDE. M. Delfaut
E. M. Delfaut
XDX. Demondion
X. Demondion
ABA. Bieganski
A. Bieganski
HCH. Cotten
H. Cotten
HMH. Mestdagh
H. Mestdagh
ACA. Cotten
A. Cotten

1 August 2003
Verified
Journal Article
Closed access
XDXavier Demondion
Xavier Demondion
PHPascal Herbinet
Pascal Herbinet
NBNathalie Boutry
Nathalie Boutry
CFChristian Fontaine
Christian Fontaine
JFJean-Paul Francke
Jean-Paul Francke
ACAnne Cotten
Anne Cotten