John D. Newell

John D. Newell

Auto-generated profile, based on publicly available information

John D. Newell

National Jewish Medical and Research Center

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Chest
Verified
Journal Article
Closed access
RARavi S. Aysola
Ravi S. Aysola
EHEric A. Hoffman
Eric A. Hoffman
DGDavid Gierada
David Gierada
SWSally Wenzel
Sally Wenzel
JCJanice Cook-Granroth
Janice Cook-Granroth
MCMario Castro
Mario Castro

1 May 2004 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
JNJ.D. Newell
J.D. Newell
JHJ.C. Hogg
J.C. Hogg
GSG.L. Snider
G.L. Snider
It has been reported that quantitative computed tomography (CT) scanning of the lungs showed decreased progression of emphysema in a randomised clinical trial in patients with severe α1‐antitrypsin (α1‐AT) deficiency receiving monthly intravenous augmentation therapy with human α1‐AT. Comparable results were not obtained using rate of decline of forced expiratory volume in one second.Accordingly, the Alpha‐1 Foundation convened a workshop to explore the feasibility of using quantitative CT data as a primary outcome variable in trials of drugs for treating α1‐AT deficiency.This report reviews the following: the principles for the use of modern CT scanners for quantifying emphysema; the methods and data on validation by comparison with measurements of severity of emphysema in inflation-fixed specimens of lungs; and the possibility of decreasing radiation dosage from CT to make it safe and ethically possible to use CT in longitudinal studies.The workshop concluded that it is feasible, safe and ethically possible to use computed tomography in longitudinal studies of emphysema. It recommended that the primary end-point should be a significant shift in the 15th percentile of lung density.

1 December 2002 in Clinical Radiology
Verified
Journal Article
Closed access
PDF file
SJS.P Jensen
S.P Jensen
DLD.A Lynch
D.A Lynch
KBK.K Brown
K.K Brown
SWS.E Wenzel
S.E Wenzel
JNJ.D Newell
J.D Newell

15 December 2008 in Proceedings of the American Thoracic Society
Verified
Journal Article
Closed access
JNJr. John D. Newell
Jr. John D. Newell
This article provides a brief overview of the important issues influencing the effective use of quantitative X-ray computed tomography (QCT) in the assessment of the lung parenchyma in patients or research subjects with chronic obstructive pulmonary disease (COPD). This effort builds on an earlier workshop that was done in 2001. The pathologic appearance of emphysema is briefly reviewed. CT scanner, CT phantom, and CT image acquisition parameters are discussed that are important in obtaining high quality CT images of the lungs for image quantitation. Data storage, data transfer and data archival issues are reviewed. Current image processing techniques to derive meaningful quantitative measures of emphysema are also discussed.

25 November 2009 in COPD: Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Closed access
PDF file
TYTsuneo Yamashiro
Tsuneo Yamashiro
SMShin Matsuoka
Shin Matsuoka
RERaúl San José Estépar
Raúl San José Estépar
ADAlejandro Diaz
Alejandro Diaz
JNJohn D. Newell
John D. Newell
GWGeorge R. Washko
George R. Washko
The relationship between quantitative airway measurements on computed tomography (CT) and airflow limitation in individuals with severe α 1-antitrypsin deficiency (AATD) is undefined. Thus, we planned to clarify the relationship between CT-based airway indices and airflow limitation in AATD. 52 patients with AATD underwent chest CT and pre-bronchodilator spirometry at three institutions. In the right upper (RUL) and lower (RLL) lobes, wall area percent (WA%) and luminal area (Ai) were measured in the third, fourth, and fifth generations of the bronchi. The severity of emphysema was also calculated in each lobe and expressed as low attenuation area percent (LAA%). Correlations between obtained measurements and FEV1% predicted (FEV1%P) were evaluated by the Spearman rank correlation test. In RUL, WA% of all generations was significantly correlated with FEV1%P (3rd, R = −0.33, p = 0.02; 4th, R = −0.39, p = 0.004; 5th, R = −0.57, p < 0.001; respectively). Ai also showed significant correlations (3rd, R = 0.32, p = 0.02; 4th, R = 0.34, p = 0.01; 5th, R = 0.56, p < 0.001; respectively). Measured correlation coefficients improved when the airway progressed distally from the third to fifth generations. LAA% also correlated with FEV1%P (R = −0.51, p < 0.001). In RLL, WA% showed weak correlations with FEV1%P in all generations (3rd, R = −0.34, p = 0.01; 4th, R = −0.30, p = 0.03; 5th, R = −0.31, p = 0.03; respectively). Only Ai from the fifth generation significantly correlated with FEV1%P in this lobe (R = 0.34, p = 0.01). LAA% strongly correlated with FEV1%P (R = −0.71, p < 0.001). We conclude therefore that quantitative airway measurements are significantly correlated with airflow limitation in AATD, particularly in the distal airways of RUL. Emphysema of the lower lung is the predominant component; however, airway disease also has a significant impact on airflow limitation in AATD.

1 January 2002 in Radiologic Clinics of North America
Verified
Journal Article
Closed access
JNJohn D Newell
John D Newell