15 February 2022 in Neurology
Background and Objectives The restoration of touch to fingers and fingertips is critical to achieving dexterous neuroprosthetic control for individuals with sensorimotor dysfunction. However, localized fingertip sensations have not been evoked via intracortical microstimulation (ICMS). Methods Using a novel intraoperative mapping approach, we implanted electrode arrays in the finger areas of left and right somatosensory cortex and delivered ICMS over a 2-year period in a human participant with spinal cord injury. Results Stimulation evoked tactile sensations in 8 fingers, including fingertips, spanning both hands. Evoked percepts followed expected somatotopic arrangements. The subject was able to reliably identify up to 7 finger-specific sites spanning both hands in a finger discrimination task. The size of the evoked percepts was on average 33% larger than a finger pad, as assessed via manual markings of a hand image. The size of the evoked percepts increased modestly with increased stimulation intensity, growing 21% as pulse amplitude increased from 20 to 80 µA. Detection thresholds were estimated on a subset of electrodes, with estimates of 9.2 to 35 µA observed, roughly consistent with prior studies. Discussion These results suggest that ICMS can enable the delivery of consistent and localized fingertip sensations during object manipulation by neuroprostheses for individuals with somatosensory deficits. ClinicalTrials.gov Identifier NCT03161067.
1 August 2023 in Journal of Neural Engineering
Objective. The speech production network relies on a widely distributed brain network. However, research and development of speech brain–computer interfaces (speech-BCIs) has typically focused on decoding speech only from superficial subregions readily accessible by subdural grid arrays—typically placed over the sensorimotor cortex. Alternatively, the technique of stereo-electroencephalography (sEEG) enables access to distributed brain regions using multiple depth electrodes with lower surgical risks, especially in patients with brain injuries resulting in aphasia and other speech disorders. Approach. To investigate the decoding potential of widespread electrode coverage in multiple cortical sites, we used a naturalistic continuous speech production task. We obtained neural recordings using sEEG from eight participants while they read aloud sentences. We trained linear classifiers to decode distinct speech components (articulatory components and phonemes) solely based on broadband gamma activity and evaluated the decoding performance using nested five-fold cross-validation. Main Results. We achieved an average classification accuracy of 18.7% across 9 places of articulation (e.g. bilabials, palatals), 26.5% across 5 manner of articulation (MOA) labels (e.g. affricates, fricatives), and 4.81% across 38 phonemes. The highest classification accuracies achieved with a single large dataset were 26.3% for place of articulation, 35.7% for MOA, and 9.88% for phonemes. Electrodes that contributed high decoding power were distributed across multiple sulcal and gyral sites in both dominant and non-dominant hemispheres, including ventral sensorimotor, inferior frontal, superior temporal, and fusiform cortices. Rather than finding a distinct cortical locus for each speech component, we observed neural correlates of both articulatory and phonetic components in multiple hubs of a widespread language production network. Significance. These results reveal the distributed cortical representations whose activity can enable decoding speech components during continuous speech through the use of this minimally invasive recording method, elucidating language neurobiology and neural targets for future speech-BCIs.
1 March 2021 in Journal of Neurosurgery
Defining eloquent cortex intraoperatively, traditionally performed by neurosurgeons to preserve patient function, can now help target electrode implantation for restoring function. Brain-machine interfaces (BMIs) have the potential to restore upper-limb motor control to paralyzed patients but require accurate placement of recording and stimulating electrodes to enable functional control of a prosthetic limb. Beyond motor decoding from recording arrays, precise placement of stimulating electrodes in cortical areas associated with finger and fingertip sensations allows for the delivery of sensory feedback that could improve dexterous control of prosthetic hands. In this study, the authors demonstrated the use of a novel intraoperative online functional mapping (OFM) technique with high-density electrocorticography to localize finger representations in human primary somatosensory cortex. In conjunction with traditional pre- and intraoperative targeting approaches, this technique enabled accurate implantation of stimulating microelectrodes, which was confirmed by postimplantation intracortical stimulation of finger and fingertip sensations. This work demonstrates the utility of intraoperative OFM and will inform future studies of closed-loop BMIs in humans.
7 January 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Brain-machine interface (BMI) researchers have traditionally focused on modeling endpoint reaching tasks to provide the control of neurally driven prosthetic arms. Most previous research has focused on achieving an endpoint control through a Cartesian-coordinate-centered approach. However, a joint-centered approach could potentially be used to intuitively control a wide range of limb movements. We systematically investigated the feasibility of discriminating between flexion and extension of different upper limb joints using electrocorticography(ECoG) recordings from sensorimotor cortex. Four subjects implanted with macro-ECoG (10-mm spacing), high-density ECoG (5-mm spacing), and/or micro-ECoG arrays (0.9-mm spacing and 4 mm × 4 mm coverage), performed randomly cued flexions or extensions of the fingers, wrist, or elbow contralateral to the implanted hemisphere. We trained a linear model to classify six movements using averaged high-gamma power (70-110 Hz) modulations at different latencies with respect to movement onset, and within a time interval restricted to flexion or extension at each joint. Offline decoding models for each subject classified these movements with accuracies of 62%-83%. Our results suggest that the widespread ECoG coverage of sensorimotor cortex could allow a whole limb BMI to sample native cortical representations in order to control flexion and extension at multiple joints.