Jin Hur

Jin Hur

Auto-generated profile, based on publicly available information

Jin Hur

Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Chest
Verified
Journal Article
Closed access
CPChul Hwan Park
Chul Hwan Park
KHKyunghwa Han
Kyunghwa Han
JHJin Hur
Jin Hur
SLSang Min Lee
Sang Min Lee
JLJi Won Lee
Ji Won Lee
BCByoung Wook Choi
Byoung Wook Choi

1 January 2017 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
PKPan Ki Kim
Pan Ki Kim
YHYoo Jin Hong
Yoo Jin Hong
DIDong Jin Im
Dong Jin Im
YSYoung Joo Suh
Young Joo Suh
CPChul Hwan Park
Chul Hwan Park
BCByoung Wook Choi
Byoung Wook Choi
Kim PK, et al. Korean J Radiol. 2017 Jan-Feb;18(1):113-131. https://doi.org/10.3348/kjr.2017.18.1.113

1 July 2016 in Radiology
Verified
Journal Article
Closed access
HLHye-Jeong Lee
Hye-Jeong Lee
DIDong Jin Im
Dong Jin Im
JYJong-Chan Youn
Jong-Chan Youn
SCSuyon Chang
Suyon Chang
YSYoung Joo Suh
Young Joo Suh
BCByoung Wook Choi
Byoung Wook Choi
Myocardial extracellular volume fraction determined with dual-energy equilibrium contrast-enhanced cardiac CT showed good agreement, with a small bias and acceptable 95% limits of agreement when compared with cardiac MR imaging, as well as excellent interobserver agreement. PurposeTo evaluate the feasibility of equilibrium contrast material–enhanced dual-energy cardiac computed tomography (CT) to determine extracellular volume fraction (ECV) in nonischemic cardiomyopathy (CMP) compared with magnetic resonance (MR) imaging.Materials and MethodsThis study was approved by the institutional review board; informed consent was obtained. Seven healthy subjects and 23 patients (six with hypertrophic CMP, nine with dilated CMP, four with amyloidosis, and four with sarcoidosis) (mean age ± standard deviation, 57.33 years ± 14.82; 19 male participants [63.3%]) were prospectively enrolled. Twelve minutes after contrast material injection (1.8 mL/kg at 3 mL/sec), dual-energy cardiac CT was performed. ECV was measured by two observers independently. Hematocrit levels were compared between healthy subjects and patients with the Mann-Whitney U test. In per-subject analysis, interobserver agreement for CT was assessed with the intraclass correlation coefficient (ICC), and intertest agreement...

22 August 2010 in European Radiology
Verified
Journal Article
Closed access
PDF file
GKGa Ram Kim
Ga Ram Kim
JHJin Hur
Jin Hur
SLSang Min Lee
Sang Min Lee
HLHye-Jeong Lee
Hye-Jeong Lee
YHYoo Jin Hong
Yoo Jin Hong
KCKyu Ok Choe
Kyu Ok Choe

1 June 2009 in Radiology
Verified
Journal Article
Closed access
JHJin Hur
Jin Hur
Do Young KimDo Young Kim
Do Young Kim
HLHye-Jeong Lee
Hye-Jeong Lee
JHJong-Won Ha
Jong-Won Ha
JHJi Hoe Heo
Ji Hoe Heo
BCByoung Wook Choi
Byoung Wook Choi
To assess the diagnostic accuracy of two-phase 64-section cardiac computed tomographic (CT) angiography for detection of left atrial appendage (LAA) thrombi and differentiation between thrombus and circulatory stasis in patients with stroke, with transesophageal echocardiography (TEE) as the reference standard. This study was institutional review board approved, and all patients gave written informed consent. Fifty-five consecutive patients (36 men, 19 women; mean age, 61 years) who had recently experienced a stroke, had high-risk factors for thrombus formation, and underwent both two-phase 64-section cardiac CT angiography and TEE up to 5 days apart were examined. Agreement between CT and TEE for detection of thrombus was assessed with kappa statistics. For quantitative analysis, the LAA-ascending aorta attenuation ratio (LAA/AA, in Hounsfield units) was measured on early- and late-phase CT images. The significance of differences in CT attenuation measurements were assessed by using the Student t test. A total of 14 thrombi were detected in the 55 patients at TEE. With TEE as the reference standard, the overall sensitivity, specificity, and positive and negative predictive values of cardiac CT angiography for the detection of thrombus in the LAA were 100% (14 of 14 patients), 98% (40 of 41 patients), 93% (14 of 15 patients), and 100% (40 of 40 patients), respectively. Concordance between cardiac CT angiography and TEE for the detection of thrombus in the LAA was high (overall kappa = 0.953). Mean LAA/AA values were significantly different between thrombus (0.29 HU +/- 0.12 [standard deviation]) and circulatory stasis (0.85 HU +/- 0.12) on late-phase CT images (P < .001). Two-phase 64-section cardiac CT angiography is a noninvasive sensitive modality for detecting LAA thrombi and differentiating thrombus from circulatory stasis in stroke patients.

1 June 2012 in Radiology
Verified
Journal Article
Closed access
JHJin Hur
Jin Hur
Do Young KimDo Young Kim
Do Young Kim
HLHye-Jeong Lee
Hye-Jeong Lee
JNJi Eun Nam
Ji Eun Nam
YHYoo Jin Hong
Yoo Jin Hong
BCByoung Wook Choi
Byoung Wook Choi
To assess the diagnostic performance of dual-energy cardiac computed tomography (CT) in the detection of left atrial appendage (LAA) thrombi and differentiation between thrombus and circulatory stasis in patients with stroke, by using transesophageal echocardiography (TEE) as the reference standard. The institutional review board approved this study, and patients provided informed consent. Thirty-two patients with stroke who had atrial fibrillation (AF) and either thrombus or the spontaneous echo contrast (SEC) echo pattern at TEE were prospectively enrolled. For the control group, 31 patients who were planning to undergo AF ablation and who had no abnormalities at TEE were enrolled. All patients underwent dual-energy cardiac CT that was not electrocardiographically gated. For quantitative analysis, iodine concentration was measured on CT images. The statistical significance of differences in mean iodine concentration between thrombus and SEC as measured at CT was assessed by using the Student t test. Among the 63 patients, a total of 13 thrombi and 19 instances of SEC were detected at TEE. Using TEE as the reference standard, the overall sensitivity, specificity, positive predictive value, and negative predictive value of dual-energy cardiac CT in the detection of thrombi and SEC in the LAA were 97% (95% confidence interval [CI]: 82%, 100%), 100% (95% CI: 86%, 100%), 100%, and 97%, respectively. At CT, the mean iodine concentration was 1.23 mg/mL ± 0.34 (standard deviation) for thrombus and 3.61 mg/mL ± 1.01 for SEC (P = .001). Dual-energy cardiac CT is a highly sensitive modality for detecting LAA thrombus and for differentiating thrombus from SEC in patients with stroke.