Andre S. Pollmann

Andre S. Pollmann

Auto-generated profile, based on publicly available information

Andre S. Pollmann

Centre Hospitalier de l'Université de Montréal, Montréal, QC, Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2015 in BMC Pharmacology and Toxicology
Verified
Journal Article
Open access
PDF file
APAndré S. Pollmann
André S. Pollmann
AMAndrea Lynn Murphy
Andrea Lynn Murphy
JBJoel C. Bergman
Joel C. Bergman
DGDavid M. Gardner
David M. Gardner
Long-term sedative use is prevalent and associated with significant morbidity, including adverse events such as falls, cognitive impairment, and sedation. The development of dependence can pose significant challenges when discontinuation is attempted as withdrawal symptoms often develop. We conducted a scoping review to map and characterize the literature and determine opportunities for future research regarding deprescribing strategies for long-term benzodiazepine and Z-drug (zopiclone, zolpidem, and zaleplon) use in community-dwelling adults. We searched PubMed, Cochrane Central Register of Controlled Trials, EMBASE, PsycINFO, CINAHL, TRIP, and JBI Ovid databases and conducted a grey literature search. Articles discussing methods for deprescribing benzodiazepines or Z-drugs in community-dwelling adults were selected. Following removal of duplicates, 2797 articles were reviewed for eligibility. Of these, 367 were retrieved for full-text assessment and 139 were subsequently included for review. Seventy-four (53 %) articles were original research, predominantly randomized controlled trials (n = 52 [37 %]), whereas 58 (42 %) were narrative reviews and seven (5 %) were guidelines. Amongst original studies, pharmacologic strategies were the most commonly studied intervention (n = 42 [57 %]). Additional deprescribing strategies included psychological therapies (n = 10 [14 %]), mixed interventions (n = 12 [16 %]), and others (n = 10 [14 %]). Behaviour change interventions were commonly combined and included enablement (n = 56 [76 %]), education (n = 36 [47 %]), and training (n = 29 [39 %]). Gradual dose reduction was frequently a component of studies, reviews, and guidelines, but methods varied widely. Approaches proposed for deprescribing benzodiazepines and Z-drugs are numerous and heterogeneous. Current research in this area using methods such as randomized trials and meta-analyses may too narrowly encompass potential strategies available to target this phenomenon. Realist synthesis methods would be well suited to understand the mechanisms by which deprescribing interventions work and why they fail.

1 April 2020 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
APAndré S. Pollmann
André S. Pollmann
DLDarrell R. Md Lewis
Darrell R. Md Lewis
RGR. Rishi Md Gupta
R. Rishi Md Gupta
Purpose: To compare fracture characteristics of intraocular lenses (IOLs) used in transscleral fixation with the Gore-Tex suture. Setting: Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada. Design: Experimental study. Methods: A model was designed to compare the eyelet fracture characteristics of enVista MX60 IOL (model available before June 2018), the enVista MX60E IOL (current model), the Akreos AO60 IOL, and the CZ70BD IOL. Tension was applied through the Gore-Tex suture and measured with a digital force gauge. Two suture configurations (radial and nonradial) were tested using the MX60E IOL. Results: A total of 25 trials were conducted. The mean eyelet fracture force was 1.666 newtons (N) for the MX60 IOL (range, 1.000–2.000), 1.000 N for the MX60E IOL (range, 1.000–1.000), 2.330 N for the AO60 IOL (range, 2.000–3.000), and 0.998 N for the CZ70BD IOL (range, 0.990–1.000). When compared with the MX60E IOL, a greater eyelet strength was observed with the MX60 (P = .024) and AO60 (P = .004) IOLs. Radial and nonradial suture configurations did not affect the MX60E eyelet fracture force. Conclusions: The enVista MX60E eyelet may be less resistant to Gore-Tex suture tear out compared with the MX60 and AO60 IOLs. Altering suture configuration did not affect enVista eyelet resistance to fracture. During off-label use in transscleral fixation, extra caution should be taken when handling IOLs and applying tension on sutures.

11 September 2015 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Verified
Journal Article
Closed access
PDF file
KTKabilan Thanapaalasingham
Kabilan Thanapaalasingham
APAndré S. Pollmann
André S. Pollmann
BSBenjamin Schelew
Benjamin Schelew

9 February 2022 in Canadian Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
APAndré S. Pollmann
André S. Pollmann
AZAngela Zhang
Angela Zhang
LSLesya M. Shuba
Lesya M. Shuba

20 February 2024 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
APAndré S. Pollmann
André S. Pollmann
MNMichael Trong Duc Nguyen
Michael Trong Duc Nguyen
MKMilime Keyeutat
Milime Keyeutat
ÉDÉliane Danis
Éliane Danis
GDGeorges M. Durr
Georges M. Durr
SJSamir Jabbour
Samir Jabbour
To report the refractive outcomes of long (≥25.00 mm) and short (≤22.00 mm) axial length (AL) eyes undergoing immediately sequential bilateral cataract surgery (ISBCS). In this retrospective cohort study, patients who underwent ISBCS were identified and eyes of patients with bilateral long and short ALs were included. Pre- and postoperative biometry, autorefraction, and ocular comorbidities or complications were recorded. The primary outcome was the mean refractive prediction error. Thirty-seven patients (74 eyes) with long ALs and 18 patients (36 eyes) with short ALs were included. The means ± standard deviations of the ALs were 26.40 ± 1.38 mm and 21.44 ± 0.46 mm in the long and short AL groups, respectively. In long AL eyes, the mean absolute error from the biometry-predicted refraction was − 0.16 ± 0.46 D, corresponding to 74% of eyes achieving a refraction within ±0.50 D of the predicted value. In short AL eyes, the mean absolute error was − 0.63 ± 0.73 D, corresponding to 44% of eyes achieving a refraction within ±0.50 D of the predicted value. Eight (44.4%) patients with short AL eyes had a myopic deviation greater than ±0.50 D from the predicted result in both eyes. Compared to patients with long AL eyes, ISBCS in patients with short ALs had a wider variance in refractive outcome and a lower rate of achieving a postoperative refraction within ±0.50 D of the predicted target.

1 September 2020 in American Journal of Ophthalmology Case Reports
Verified
Journal Article
Open access
APAndré S. Pollmann
André S. Pollmann
AMAmit V. Mishra
Amit V. Mishra
MCMaria Gabriela Campos-Baniak
Maria Gabriela Campos-Baniak
RGR. Rishi Gupta
R. Rishi Gupta
BEBrennan D. Eadie
Brennan D. Eadie
Delayed hypotony can be a vision threatening complication following aqueous shunt surgery in patients with glaucoma. Multiple medical and surgical management strategies have been utilized, but results have been inconsistent. The present case series describes management of delayed hypotony associated with the Baerveldt glaucoma implant (BGI) by surgically introducing 4-0 polypropylene suture into the tube lumen. The cases of four patients who presented with hypotony following BGI surgery were reviewed. Following BGI tube lumen occlusion with suture, sustained intraocular pressure increase (mean 7.25 mmHg, range 4-14) was noted in all patients and visual acuity improved in three cases. This is the first report of ab interno suture occlusion of the BGI for management of post-operative hypotony. Further studies are required to determine the utility of this procedure, but our results suggest that in select patients, ab interno suture occlusion be advantageous in managing delayed hypotony refractive to medical therapy.