26 April 2019 in Nature Communications
Determining the brain perfusion is an important task for diagnosis of vascular diseases such as occlusions and intracerebral haemorrhage. Even after successful diagnosis, there is a high risk of restenosis or rebleeding such that patients need intense attention in the days after treatment. Within this work, we present a diagnostic tomographic imager that allows access to brain perfusion quantitatively in short intervals. The device is based on the magnetic particle imaging technology and is designed for human scale. It is highly sensitive and allows the detection of an iron concentration of 263 pmolFe ml−1, which is one of the lowest iron concentrations imaged by MPI so far. The imager is self-shielded and can be used in unshielded environments such as intensive care units. In combination with the low technical requirements this opens up a variety of medical applications and would allow monitoring of stroke on intensive care units.
12 October 2018 in IEEE Transactions on Medical Imaging
Due to peripheral nerve stimulation the magnetic particle imaging (MPI) method is limited in the maximum applicable excitation-field amplitude. This in turn leads to a limitation of the size of the covered field of view (FoV) to few millimeters. In order to still capture a larger field of view, MPI is capable to rapidly acquire volumes in a multi-patch fashion. To this end, the small excitation volume is shifted through space using the magnetic focus fields. Recently it has been shown that the individual patches are preferably reconstructed in a joint fashion by solving a single linear system of equations taking the coupling between individual patches into account. While this improves the image quality, it is computationally and memory demanding since the size of the linear system increases in the best case quadratically with the number of patches. In this work, we will develop a reconstruction algorithm for MPI multi-patch data exploiting the sparsity of the joint system matrix. A highly efficient implicit matrix format allows for rapid on-the-fly calculations of linear algebra operations involving the system matrix. Using this approach the computational effort can be reduced to a linear dependence on the number of used patches. The algorithm is validated on 3D multi-patch phantom datasets and shown to reconstruct a large datasets with 15 patches in less than 22 seconds.
23 April 2021 in Physics in Medicine & Biology
Magnetic particle imaging (MPI) is a tomographic imaging technique for determining the spatial distribution of superparamagnetic nanoparticles. Current MPI systems are capable of imaging iron masses over a wide dynamic range of more than four orders of magnitude. In theory, this range could be further increased using adaptive amplifiers, which prevent signal clipping. While this applies to a single sample, the dynamic range is severely limited if several samples with different concentrations or strongly inhomogeneous particle distributions are considered. One scenario that occurs quite frequently in pre-clinical applications is that a highly concentrated tracer bolus in the vascular system ‘shadows’ nearby organs with lower effective tracer concentrations. The root cause of the problem is the ill-posedness of the MPI imaging operator, which requires regularization for stable reconstruction. In this work, we introduce a simple two-step algorithm that increases the dynamic range by a factor of four. Furthermore, the algorithm enables spatially adaptive regularization, i.e. highly concentrated signals can be reconstructed with maximum spatial resolution, while low concentrated signals are strongly regularized to prevent noise amplification.
1 June 2019 in Physics in Medicine & Biology
Magnetic particle imaging (MPI) is a tracer-based imaging technique that can be used for imaging vessels and organ perfusion with high temporal resolution. Background signals are a major source for image artifacts and in turn restrict the sensitivity of the method in practice. While static background signals can be removed from the measured signal by taking a dedicated background scan and performing subtraction, this simple procedure is not applicable in case of non-stationary background signals that occur in practice due to e.g. temperature drifts in the electromagnetic coils of the MPI scanner. Within this work we will investigate a dynamic background subtraction method that is based on two background measurements taken before and after the object measurement. Using first-order interpolation it is possible to remove linear background changes and in turn significantly suppress artifacts. The method is evaluated using static and dynamic phantom measurements and it is shown that dynamic background subtraction is capable of reducing the artifact level approximately by a factor of four.
1 June 2020 in IEEE Transactions on Medical Imaging
Magnetic particle imaging is a tracer based imaging technique to determine the spatial distribution of superparamagnetic iron oxide nanoparticles with a high spatial and temporal resolution. Due to physiological constraints, the imaging volume is restricted in size and larger volumes are covered by shifting object and imaging volume relative to each other. This results in reduced temporal resolution, which can lead to motion artifacts when imaging dynamic tracer distributions. A common source of such dynamic distributions are cardiac and respiratory motion in in-vivo experiments, which are in good approximation periodic. We present a raw data processing technique that combines data snippets into virtual frames corresponding to a specific state of the dynamic motion. The technique is evaluated on the basis of measurement data obtained from a rotational phantom at two different rotational frequencies. These frequencies are determined from the raw data without reconstruction and without an additional navigator signal. The reconstructed images give reasonable representations of the rotational phantom frozen in several different states of motion while motion artifacts are suppressed.
7 November 2017 in Medical Physics
Purpose: Magnetic particle imaging is a tomographic imaging modality capable of determining the distribution of magnetic nanoparticles with high temporal resolution. The spatial resolution of magnetic particle imaging is influenced by the gradient strength of the selection field used for spatial encoding. By increasing the gradient strength, the spatial resolution is improved, but at the same time the imaging volume decreases. For a high‐resolution image of an extended field‐of‐view, a multipatch approach can be used by shifting the sampling trajectory in space. As the total imaging timescales with the number of patches, the downside of the multipatch method is the degradation of the temporal resolution.Methods: The purpose of this work was to develop a scanning procedure incorporating the advantages of imaging at multiple gradient strengths. A low‐resolution overview scan is performed at the beginning followed by a small number of high‐resolution scans at adaptively detected locations extracted from the low‐resolution scan.Results: By combining all data during image reconstruction, it is possible to obtain a large field‐of‐view image of anisotropic spatial resolution. It is measured in a fraction of time compared to a fully sampled high‐resolution field of view image.Conclusions: Magnetic particle imaging is a flexible imaging method allowing to rapidly scan small volumes. When scaling magnetic particle imaging from small animal to human applications, it will be essential to keep the acquisition time low while still capturing larger volumes at high resolution. With our proposed adaptive multigradient imaging sequence, it is possible to capture a large field of view while keeping both the temporal and the spatial resolution high.