Liang Zhong

Liang Zhong

Auto-generated profile, based on publicly available information

Liang Zhong

Institute of Exercise Science and Health Engineering, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XSXian Song
Xian Song
ASAkram Samy
Akram Samy
Qiang YangQiang Yang
Qiang Yang
YYYangqiu Yang
Yangqiu Yang
LZLiang Zhong
Liang Zhong
Yuxin PengYuxin Peng
Yuxin Peng
Joint-related diseases can cause chronic symptoms and severe pain, which can be prevented and evaluated by accurate joint status monitoring. Soft strain sensors with high skin compatibility can detect strains from joint bending, making them a promising solution for joint health monitoring. Practically, over half of free-moving joints on the human body can perform omnidirectional bending, but current soft strain sensor cannot accurately quantify such angles. Moreover, strain-angle relations vary significantly with joint sizes, making sensor calibration difficult or unfeasible. Herein, this work designed and implemented an omnidirectional and size-adaptive soft bending sensor with a 3-D structure to capture pose angles for arbitrary joint bending. A dice manufacture-inspired procedure is proposed to precisely position four soft strain sensing channels. Moreover, by mathematically decoupling strain for deformation distributions, the sensor can calculate omnidirectional bending angles regardless of different joint sizes for the first time. The ability of the sensor was verified by mounting on three vulnerable joints for motion detection, thereby demonstrating its potential for reliable and accurate joint health monitoring.

14 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJianxiang Wang
Jianxiang Wang
ZNZhanguo Nie
Zhanguo Nie
LZLiang Zhong
Liang Zhong
KLKang Liang
Kang Liang
Qiang YangQiang Yang
Qiang Yang
Yuxin PengYuxin Peng
Yuxin Peng
Human gait parameter estimation and localization are very important for lower limb exoskeleton control, biped robot and biomechanics research. Gait analysis can be performed by wearable sensors worn on the lower limb joints. However, these sensors are incapable of simultaneous gait event detection and positioning, and have the problems of heading drift and low sampling rate. In order to address these limitations and fulfill the requirements of gait analysis, we propose a multi-sensor fusion technique called Shank-RIO (Shank mounted Ranging-inertial Odometry). Shank-RIO utilizes the fusion of a LiDAR ranging sensor and an inertial sensor placed on the shank to provide trajectory estimations for the feet and the body. A modified Linear Inverted Pendulum Model (LIPM) is employed to estimate gait parameters. Moreover, the heading rotation of the body is determined by analyzing the curvature of the body trajectory using step length and width. Based on these estimations, gait events, gait parameters, and body position can be estimated. We conduct experiments in various complex indoor and outdoor scenarios to evaluate the performance of Shank-RIO. The RMSE of the step length of the Shank-RIO was 2.26 cm. The positioning accuracy and positioning error within 1000 meters are 0.799% and 0.395%, respectively. The results demonstrate that Shank-RIO serves as an effective tool for gait analysis research.