Javier Barranco Garcia

Javier Barranco Garcia

Auto-generated profile, based on publicly available information

Javier Barranco Garcia

Illumicell AI

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VUVullnet Useini
Vullnet Useini
STStephanie Tanadini-Lang
Stephanie Tanadini-Lang
QLQuentin Lohmeyer
Quentin Lohmeyer
MMMirko Meboldt
Mirko Meboldt
NANicolaus Andratschke
Nicolaus Andratschke
JGJavier Barranco García
Javier Barranco García
Melanoma, the deadliest form of skin cancer, has seen a steady increase in incidence rates worldwide, posing a significant challenge to dermatologists. Early detection is crucial for improving patient survival rates. However, performing total body screening (TBS), i.e., identifying suspicious lesions or ugly ducklings (UDs) by visual inspection, can be challenging and often requires sound expertise in pigmented lesions. To assist users of varying expertise levels, an artificial intelligence (AI) decision support tool was developed. Our solution identifies and characterizes UDs from real-world wide-field patient images. It employs a state-of-the-art object detection algorithm to locate and isolate all skin lesions present in a patient’s total body images. These lesions are then sorted based on their level of suspiciousness using a self-supervised AI approach, tailored to the specific context of the patient under examination. A clinical validation study was conducted to evaluate the tool’s performance. The results demonstrated an average sensitivity of 95% for the top-10 AI-identified UDs on skin lesions selected by the majority of experts in pigmented skin lesions. The study also found that the tool increased dermatologists’ confidence when formulating a diagnosis, and the average majority agreement with the top-10 AI-identified UDs reached 100% when assisted by our tool. With the development of this AI-based decision support tool, we aim to address the shortage of specialists, enable faster consultation times for patients, and demonstrate the impact and usability of AI-assisted screening. Future developments will include expanding the dataset to include histologically confirmed melanoma and validating the tool for additional body regions.

24 August 2023 in JMIR Dermatology
Verified
Journal Article
Open access
MGMathias Gassner
Mathias Gassner
JGJavier Barranco Garcia
Javier Barranco Garcia
STStephanie Tanadini-Lang
Stephanie Tanadini-Lang
FBFabio Bertoldo
Fabio Bertoldo
FFFabienne Fröhlich
Fabienne Fröhlich
RBRalph P Braun
Ralph P Braun
Background: Previous research studies have demonstrated that medical content image retrieval can play an important role by assisting dermatologists in skin lesion diagnosis. However, current state-of-the-art approaches have not been adopted in routine consultation, partly due to the lack of interpretability limiting trust by clinical users. Objective: This study developed a new image retrieval architecture for polarized or dermoscopic imaging guided by interpretable saliency maps. This approach provides better feature extraction, leading to better quantitative retrieval performance as well as providing interpretability for an eventual real-world implementation. Methods: Content-based image retrieval (CBIR) algorithms rely on the comparison of image features embedded by convolutional neural network (CNN) against a labeled data set. Saliency maps are computer vision–interpretable methods that highlight the most relevant regions for the prediction made by a neural network. By introducing a fine-tuning stage that includes saliency maps to guide feature extraction, the accuracy of image retrieval is optimized. We refer to this approach as saliency-enhanced CBIR (SE-CBIR). A reader study was designed at the University Hospital Zurich Dermatology Clinic to evaluate SE-CBIR’s retrieval accuracy as well as the impact of the participant’s confidence on the diagnosis. Results: SE-CBIR improved the retrieval accuracy by 7% (77% vs 84%) when doing single-lesion retrieval against traditional CBIR. The reader study showed an overall increase in classification accuracy of 22% (62% vs 84%) when the participant is provided with SE-CBIR retrieved images. In addition, the overall confidence in the lesion’s diagnosis increased by 24%. Finally, the use of SE-CBIR as a support tool helped the participants reduce the number of nonmelanoma lesions previously diagnosed as melanoma (overdiagnosis) by 53%. Conclusions: SE-CBIR presents better retrieval accuracy compared to traditional CBIR CNN-based approaches. Furthermore, we have shown how these support tools can help dermatologists and residents improve diagnosis accuracy and confidence. Additionally, by introducing interpretable methods, we should expect increased acceptance and use of these tools in routine consultation.

16 July 2020 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
CTC. Tambasco
C. Tambasco
TPT. Pieloni
T. Pieloni
JBJ. Barranco
J. Barranco
XBX. Buffat
X. Buffat
TLT. Levens
T. Levens
BSB. Salvachua
B. Salvachua
The Landau damping mechanism stabilizes the impedance driven head-tail modes in hadron synchrotrons. Because of the frequent coherent beam instabilities observed in the Large Hadron Collider in 2012, the Landau damping of the beams was doubted. Therefore, a transverse beam transfer function (BTF) system was installed in order to probe the transverse Landau damping of the beams and compare the measurements with expectations. The results of the BTF measurements acquired during several experiments in the LHC are summarized including different machine configurations. The method developed for the data analysis is described, and the comparison between the models and the measurements is also presented.

15 July 2022
Verified
Book Chapter
Closed access
PDF file
DADaniel Abler
Daniel Abler
VAVincent Andrearczyk
Vincent Andrearczyk
VOValentin Oreiller
Valentin Oreiller
JGJavier Barranco Garcia
Javier Barranco Garcia
DVDiem Vuong
Diem Vuong
ADAdrien Depeursinge
Adrien Depeursinge

24 August 2022 in JMIR Preprints
Verified
Preprint
Open access
MGMathias Gassner
Mathias Gassner
JGJavier Barranco Garcia
Javier Barranco Garcia
STStephanie Tanadini-Lang
Stephanie Tanadini-Lang
FBFabio Bertoldo
Fabio Bertoldo
FFFabienne Fröhlich
Fabienne Fröhlich
RBRalph P Braun
Ralph P Braun
BACKGROUND Previous research studies have demonstrated that medical content image retrieval can play an important role by assisting dermatologists in skin lesion diagnosis. However, current state-of-the-art approaches have not been adopted in routine consultation, partly due to the lack of interpretability limiting trust by clinical users. OBJECTIVE This study developed a new image retrieval architecture for polarized or dermoscopic imaging guided by interpretable saliency maps. This approach provides better feature extraction, leading to better quantitative retrieval performance as well as providing interpretability for an eventual real-world implementation. METHODS Content-based image retrieval (CBIR) algorithms rely on the comparison of image features embedded by convolutional neural network (CNN) against a labeled data set. Saliency maps are computer vision–interpretable methods that highlight the most relevant regions for the prediction made by a neural network. By introducing a fine-tuning stage that includes saliency maps to guide feature extraction, the accuracy of image retrieval is optimized. We refer to this approach as saliency-enhanced CBIR (SE-CBIR). A reader study was designed at the University Hospital Zurich Dermatology Clinic to evaluate SE-CBIR’s retrieval accuracy as well as the impact of the participant’s confidence on the diagnosis. RESULTS SE-CBIR improved the retrieval accuracy by 7% (77% vs 84%) when doing single-lesion retrieval against traditional CBIR. The reader study showed an overall increase in classification accuracy of 22% (62% vs 84%) when the participant is provided with SE-CBIR retrieved images. In addition, the overall confidence in the lesion’s diagnosis increased by 24%. Finally, the use of SE-CBIR as a support tool helped the participants reduce the number of nonmelanoma lesions previously diagnosed as melanoma (overdiagnosis) by 53%. CONCLUSIONS SE-CBIR presents better retrieval accuracy compared to traditional CBIR CNN-based approaches. Furthermore, we have shown how these support tools can help dermatologists and residents improve diagnosis accuracy and confidence. Additionally, by introducing interpretable methods, we should expect increased acceptance and use of these tools in routine consultation.

Verified
Conference Paper
Open access
PDF file
BYBruce Yee-Rendón
Bruce Yee-Rendón
JGJavier Barranco García
Javier Barranco García
RCRama Calaga
Rama Calaga
RLRicardo Lopez-Fernandez
Ricardo Lopez-Fernandez
RGRogelio Tomas Garcia
Rogelio Tomas Garcia
FZFrank Zimmermann
Frank Zimmermann