Julia Rossmann

Julia Rossmann

Auto-generated profile, based on publicly available information

Julia Rossmann

Institute of Clinical Pharmacology, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Fiedlerstraße 27, D-01307 Dresden, Germany; Research Association Public Health Saxony and Saxony Anhalt, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Fiedlerstraße 33, D-01307 Dresden, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Journal of Chromatography B
Verified
Journal Article
Closed access
JRJulia Rossmann
Julia Rossmann
SSSara Schubert
Sara Schubert
RGRobert Gurke
Robert Gurke
ROReinhard Oertel
Reinhard Oertel
WKWilhelm Kirch
Wilhelm Kirch

1 May 2015 in Journal of Chromatography B
Verified
Journal Article
Closed access
RGRobert Gurke
Robert Gurke
JRJulia Rossmann
Julia Rossmann
SSSara Schubert
Sara Schubert
TSTobias Sandmann
Tobias Sandmann
MRMartin Rößler
Martin Rößler
JFJoachim Fauler
Joachim Fauler

1 September 2015 in Journal of Chromatography B
Verified
Journal Article
Closed access
JRJulia Rossmann
Julia Rossmann
RGRobert Gurke
Robert Gurke
LRLars David Renner
Lars David Renner
ROReinhard Oertel
Reinhard Oertel
WKWilhelm Kirch
Wilhelm Kirch


1 February 2018 in Journal of Chromatography A
Verified
Journal Article
Closed access
JRJulia Rossmann
Julia Rossmann
LRLars David Renner
Lars David Renner
ROReinhard Oertel
Reinhard Oertel
AEAli El-Armouche
Ali El-Armouche

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
JRJulia Rossmann
Julia Rossmann
SCStine Christ
Stine Christ
SGSven F Garbade
Sven F Garbade
GHGeorg Friedrich Hoffmann
Georg Friedrich Hoffmann
TOThomas Opladen
Thomas Opladen
SRSylvia Richter
Sylvia Richter
Vitamin B6 and its metabolites play a crucial role in the development and interaction of brain metabolism. Following diagnostic improvements additional inherited disorders in vitamin B6 metabolism have been identified, most of them leading to a severe epileptic disorder accompanied by progressive neurological deficits including intellectual disability and microcephaly. Since early treatment can improve the outcome, fast and reliable detection of metabolic biomarkers is important. Therefore, the analysis of vitamin B6 metabolites has become increasingly important, but is, however, still challenging and limited to a few specialized laboratories.Until today, vitamin B6 metabolites are measured by liquid chromatography tandem mass spectrometry (LC-MS/MS) using trichloroacetic acid for protein precipitation. In this work, we present the development and validation of a new, accurate and reliable method for analysis and quantification of the vitamin B6 vitamers pyridoxal 5´-phosphate (PLP), pyridoxal (PL), pyridoxine (PN), pyridoxamine (PM) and pyridoxic acid (PA) in human CSF samples using acetonitrile for protein precipitation. The method is based on ultra-performance liquid chromatography-tandem mass spectrometry using electrospray ionization (UPLC-ESI-MS/MS). The calibration was performed in surrogate matrix Ringer solution and metabolites were quantified by their corresponding isotopically labelled internal standards. A protein precipitation by acetonitrile was applied greatly improving chromatographic separation of the metabolites in a 4.7 minutes chromatographic run. The method was validated following the European Medical Agency (EMA) and Food and Drug Administration (FDA) guidelines for bioanalytical method validation. The metabolites were quantified from 5 to 200 nmol/L with a seven-point calibration curve and minimum coefficient of regression of 0.99. The validation was performed with quality control samples at four concentration levels with surrogate matrix ringer solution and pooled CSF material. Within- and inter-day accuracy and precision in Ringer solution were within 85.4 % (PLP) and 114.5 % (PM) and from 2.6 % (PA) to 16.5 % (PLP). Within- and inter-day accuracy and precision in pooled CSF material were within 90.5 % (PN) and 120.1 % (PL) and from 1.7 % (PA) to 19.0 % (PM). The method was tested by measuring of 158 CSF samples to determine reference ranges. The B6 vitamers PLP and PL were determined in all CSF samples above 5 nmol/L while PN, PM and PA showed concentrations below or near LOQ. Probable supplementation of PLP was detected in eight CSF samples, which revealed high concentrations of PM, PN, PL, or PA, whereas PLP was in the reference range or slightly elevated. The method is suitable for the application within a routine diagnostic laboratory.