The direct method (HA(soln) ⇌ A(soln)– + H(soln)+) for calculating pKa of monoprotic acids is as efficient as thermodynamic cycles. A selective adjustment of proton free energy in solution was used with experimental pKa data. The procedure was analyzed at different levels of theory. The solvent was described by the solvation model density (SMD) model, including or not explicit water molecules, and three training sets were tested. The best performance under any condition was obtained by the G4CEP method with a mean absolute error close to 0.5 units of pKa and an uncertainty around ±1 unit of pKa for any training set including or excluding explicit solvent molecules. PM6 and AM1 performed very well with average absolute errors below 0.75 units of pKa but with uncertainties up to ±2 units of pKa, using only the SMD solvent model. Density functional theory (DFT) results were highly dependent on the basis functions and explicit water molecules. The best performance was observed for the local spin density approximation (LSDA) functional in almost all calculations and under certain conditions, as high as those obtained by G4CEP. Basis set complexity and explicit solvent molecules were important factors to control DFT calculations. The training set molecules should consider the diversity of compounds.
This paper describes the development, characterization and application of an Nb2O5 film formed on the surface of a carbon ceramic material, SiO2/C, obtained by a sol–gel method, using the spin-coating technique. The working electrode using this material will be designated as SiCNb. Hydroquinone and catechol can be oxidized at this electrode in the presence of resorcinol, allowing their simultaneous detection. The electrochemical properties of the resulting electrode were investigated using cyclic and differential pulse voltammetry techniques. Well-defined and separated oxidation peaks were observed by differential pulse voltammetry in Tris–HCl buffer solution at pH 7 containing 1 mol L−1 KCl in the supporting electrolyte solution. The SiCNb electrode exhibited high sensitivity in the simultaneous determination of hydroquinone and catechol in the presence of resorcinol, with the limits of detection for hydroquinone and catechol being 1.6 μmol L−1 and 0.8 μmol L−1, respectively. Theoretical calculations were performed to determine the ionization energies of hydroquinone, catechol and resorcinol; the results were used to explain the simultaneous determination of species by differential pulse voltammetry. The presence of resorcinol did not produce any interference in the simultaneous detection of hydroquinone and catechol on the surface of the modified electrode.