Ana Ribeiro

Ana Ribeiro

Auto-generated profile, based on publicly available information

Ana Ribeiro

Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London, SW7 3RP, United Kingdom; Artificial Intelligence Imaging Hub, The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, SM2 5PT, United Kingdom; Department of Medical Oncology, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, the Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Radiography
Verified
Journal Article
Open access
ARA. Ribeiro
A. Ribeiro
Olga HussonOlga Husson
Olga Husson
NDN. Drey
N. Drey
IMI. Murray
I. Murray
KMK. May
K. May
WOW. Oyen
W. Oyen
Medical imaging is the main source of artificial radiation exposure. Evidence, however, suggests that patients are poorly informed about radiation exposure when attending diagnostic scans. This review provides an overview of published literature with a focus on nuclear medicine patients on the level of awareness of radiation exposure from diagnostic imaging. A review of available literature on awareness, knowledge and perception of ionising radiation in medical imaging was conducted. Articles that met the inclusion criteria were subjected to critical appraisal using the Mixed Methods Appraisal Tool. 140 articles identified and screened for eligibility, 24 critically assessed and 4 studies included in synthesis. All studies demonstrated that patients were generally lacking awareness about radiation exposure and highlighted a lack of communication between healthcare professionals and patients with respect to radiation exposure. Studies demonstrate a need to better inform patients about their radiation exposure, and further studies focusing on nuclear medicine patients are particularly warranted. Adequate and accurate information is crucial to ensure the principle of informed consent is present.

29 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
ACAntonio Candito
Antonio Candito
RHRichard Holbrey
Richard Holbrey
ARAna Ribeiro
Ana Ribeiro
CMChristina Messiou
Christina Messiou
NTNina Tunariu
Nina Tunariu
MBMatthew Blackledge
Matthew Blackledge
Background: Whole-Body Diffusion-Weighted Imaging (WBDWI) is an established technique for staging and evaluating treatment response in patients with multiple myeloma (MM) and advanced prostate cancer (APC). However, WBDWI scans show inter- and intra-patient intensity signal variability. This variability poses challenges in accurately quantifying bone disease, tracking changes over follow-up scans, and developing automated tools for bone lesion delineation. Here, we propose a novel automated pipeline for inter-station, inter-scan image signal standardisation on WBDWI that utilizes robust segmentation of the spinal canal through deep learning. Methods: We trained and validated a supervised 2D U-Net model to automatically delineate the spinal canal (both the spinal cord and surrounding cerebrospinal fluid, CSF) in an initial cohort of 40 patients who underwent WBDWI for treatment response evaluation (80 scans in total). Expert-validated contours were used as the target standard. The algorithm was further semi-quantitatively validated on four additional datasets (three internal, one external, 207 scans total) by comparing the distributions of average apparent diffusion coefficient (ADC) and volume of the spinal cord derived from a two-component Gaussian mixture model of segmented regions. Our pipeline subsequently standardises WBDWI signal intensity through two stages: (i) normalisation of signal between imaging stations within each patient through histogram equalisation of slices acquired on either side of the station gap, and (ii) inter-scan normalisation through histogram equalisation of the signal derived within segmented spinal canal regions. This approach was semi-quantitatively validated in all scans available to the study (N = 287). Results: The test dice score, precision, and recall of the spinal canal segmentation model were all above 0.87 when compared to manual delineation. The average ADC for the spinal cord (1.7 × 10−3 mm2/s) showed no significant difference from the manual contours. Furthermore, no significant differences were found between the average ADC values of the spinal cord across the additional four datasets. The signal-normalised, high-b-value images were visualised using a fixed contrast window level and demonstrated qualitatively better signal homogeneity across scans than scans that were not signal-normalised. Conclusion: Our proposed intensity signal WBDWI normalisation pipeline successfully harmonises intensity values across multi-centre cohorts. The computational time required is less than 10 s, preserving contrast-to-noise and signal-to-noise ratios in axial diffusion-weighted images. Importantly, no changes to the clinical MRI protocol are expected, and there is no need for additional reference MRI data or follow-up scans.

14 November 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
ACAntonio Candito
Antonio Candito
MBMatthew D Blackledge
Matthew D Blackledge
RHRichard Holbrey
Richard Holbrey
NPNuria Porta
Nuria Porta
ARAna Ribeiro
Ana Ribeiro
DKDow-Mu Koh
Dow-Mu Koh
Objective . Quantitative assessment of treatment response in advanced prostate cancer (APC) with bone metastases remains an unmet clinical need. Whole-body diffusion-weighted MRI (WB-DWI) provides two response biomarkers: total diffusion volume (TDV) and global apparent diffusion coefficient (gADC). However, tracking post-treatment changes of TDV and gADC from manually delineated lesions is cumbersome and increases inter-reader variability. We developed a software to automate this process. Approach . Core technologies include: (i) a weakly-supervised Residual U-Net model generating a skeleton probability map to isolate bone; (ii) a statistical framework for WB-DWI intensity normalisation, obtaining a signal-normalised b = 900 s mm −2 (b900) image; and (iii) a shallow convolutional neural network that processes outputs from (i) and (ii) to generate a mask of suspected bone lesions, characterised by higher b900 signal intensity due to restricted water diffusion. This mask is applied to the gADC map to extract TDV and gADC statistics. We tested the tool using expert-defined metastatic bone disease delineations on 66 datasets, assessed repeatability of imaging biomarkers ( N = 10), and compared software-based response assessment with a construct reference standard , defined as multidisciplinary consensus based on ⩾12 months of imaging, clinical, and laboratory follow-up ( N = 118). Main results . Average dice score between manual and automated delineations was 0.6 for lesions within pelvis and spine, with an average surface distance of 2 mm. Relative differences for log-transformed TDV (log-TDV) and median gADC were 8.8% and 5%, respectively. Repeatability analysis showed coefficients of variation of 4.6% for log-TDV and 3.5% for median gADC, with intraclass correlation coefficients of 0.94 or higher. The software achieved 80.5% accuracy, 84.3% sensitivity, and 85.7% specificity in assessing response to treatment. Average computation time was 90 s per scan. Significance . Our software enables reproducible TDV and gADC quantification from WB-DWI scans for monitoring metastatic bone disease response, thus providing potentially useful measurements for clinical decision-making in APC patients.

29 August 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
ACAntonio Candito
Antonio Candito
ADAlina Dragan
Alina Dragan
RHRichard Holbrey
Richard Holbrey
ARAna Ribeiro
Ana Ribeiro
RDRicardo Donners
Ricardo Donners
MBMatthew Blackledge
Matthew Blackledge

20 September 2024 in Health Policy and Technology
Verified
Journal Article
Open access
ARAna S.F. Ribeiro
Ana S.F. Ribeiro
Olga HussonOlga Husson
Olga Husson
MRMilou Reuvers
Milou Reuvers
Wim J.G. OyenWim J.G. Oyen
Wim J.G. Oyen
CMChristina Messiou
Christina Messiou
Winette van der GraafWinette van der Graaf
Winette van der Graaf
Background: Digital Health Records (DHR) have become essential for managing patient data, including radiology and nuclear medicine reports. The wider adoption of DHR globally presents an opportunity to improve patient engagement and empowerment through effective access and sharing of imaging investigations. This review aims to synthesize literature on views, experiences, expectations, and preferences of oncology patients and healthcare professionals (HCP) when accessing imaging via DHR. Materials and Methods: This review was conducted using recommended Cochrane Handbook databases (registration: CRD42021213808), focusing on English articles published from 2000 onwards. Three experienced reviewers critically appraised selected articles, thematic analysis and narrative synthesis were used to extract data. Results: 493 unique articles were identified, with 451 excluded, resulting in 42 articles assessed for eligibility. Nine studies were included, eight from the USA, one from Canada, published between 2010 and 2020. Findings suggest patient portals can positively impact patient and HCP engagement, and patients desire access to their imaging reports. Factors such as timing of access, adequate consultation time, resources for HCP to discuss findings, and format of information are critical considerations that influence both patient and HCP perceptions and preferences. Conclusion: Oncology patients want timely and understandable access to their imaging records. To ensure this, it is crucial to explore the appropriate timing, format, and methods to discuss these findings with patients. By involving all stakeholders in the planning process, we can develop DHR systems that provide personalised support for patients to manage their complex imaging results.

2 August 2019 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
ARAna Sofia Ribeiro
Ana Sofia Ribeiro
MLMartin Lee
Martin Lee
Wim J.G. OyenWim J.G. Oyen
Wim J.G. Oyen