Dae Hee Kim

Dae Hee Kim

Auto-generated profile, based on publicly available information

Dae Hee Kim

Department of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Korea

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
PDF file
JYJi Young Yoo
Ji Young Yoo
DKDae Hee Kim
Dae Hee Kim
HCHo Choi
Ho Choi
KKKun Kim
Kun Kim
YCYun Jeong Chae
Yun Jeong Chae
SPSung Yong Park
Sung Yong Park

1 March 2018 in Medicine
Verified
Journal Article
Open access
PDF file
JYJi Young Yoo
Ji Young Yoo
SPSung Yong Park
Sung Yong Park
JKJong Yeop Kim
Jong Yeop Kim
MKMyungseob Kim
Myungseob Kim
SHSeok Jin Haam
Seok Jin Haam
DKDae Hee Kim
Dae Hee Kim
Double lumen endobronchial tube (DLT) intubation is commonly used for one-lung ventilation in thoracic surgery. However, because of its large size and shape, it is difficult to perform intubation compared with a single lumen tube. The aim of this randomized controlled trial was to determine whether the McGrath videolaryngoscope has any advantage over the direct Macintosh laryngoscope for DLT intubation in patients with a simulated difficult airway. Forty-four patients (19–60 years of age); scheduled to undergo general anesthesia with one-lung ventilation were assigned to 1 of 2 groups: DLT intubation with the McGrath videolaryngoscope (ML group [n = 22]); or conventional Macintosh laryngoscope (DL group [n = 22]). After manual in-line stabilization was applied as a way of simulating a difficult airway, the time required for intubation and the quality of glottic view were evaluated. The time to successful intubation was not different between the 2 groups (ML group, 45 s [interquartile range, 38–52 s] versus DL group, 54 s [45–59 s]; P = .089). The McGrath videolaryngoscope, however, provided a significantly better glottic view. Modified Cormack and Lehane grade was better (P < .001), and the percentage of glottis opening score was higher in the ML group (P < .001). Overall intubation difficulty scale score was lower in the ML group (1 [0–2]) versus the DL group (3 [2–4]) (P < .001). The McGrath videolaryngoscope improved glottic view and resulted in lower overall intubation difficulty scale score in patients with in-line stabilization.

1 March 2019 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
JYJi Young Yoo
Ji Young Yoo
YCYun Jeong Chae
Yun Jeong Chae
SPSung Yong Park
Sung Yong Park
SHSeokjin Haam
Seokjin Haam
MKMyungseob Kim
Myungseob Kim
DKDae Hee Kim
Dae Hee Kim
Background: Direct insertion of a double-lumen endobronchial tube (DLT) over a fibreoptic bronchoscope (FOB) is considered more difficult and traumatic than that of a single-lumen tube (SLT). We hypothesized that time to intubation over an FOB using a silicone left DLT would be non-inferior to that using a polyvinyl chloride (PVC) SLT. Methods: Eighty patients were enrolled in this open-label, randomized controlled, non-inferiority trial. Patients were randomly allocated to fibreoptic tracheal intubation with either a silicone DLT or PVC SLT (DLT and SLT groups, respectively). Time to tracheal intubation [time to insertion of FOB plus railroading (advancement over the FOB) time]; total time for correct tube and bronchial blocker positioning; difficulty of railroading; and the incidence of sore throat, swallowing difficulty, and hoarseness were compared between groups. Results: The median time to intubation over the FOB was 20 s in the DLT group and 23 s in the SLT group. The upper limit of the confidence interval of this difference was below the non-inferiority margin of 10 s (median difference: –2 s; 95% confidence interval: –4 to 0 s). Railroading time was significantly shorter in the DLT group than in the SLT group (median time: 10 vs. 11 s; median difference: –1 s; 95% confidence interval: –3 to 0 s; P=0.03). Railroading over the FOB (rated on a four-point scale) was less difficult in the DLT group than in the SLT group (P<0.01). Conclusions: Tracheal intubation using an FOB can be achieved at least as fast using the silicone DLT as using the PVC SLT. The silicone DLT exhibited superior railroading performance to the PVC SLT.

26 November 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JYJi Young Yoo
Ji Young Yoo
YCYun Jeong Chae
Yun Jeong Chae
YLYoung Bok Lee
Young Bok Lee
SKSujin Kim
Sujin Kim
JLJaemoon Lee
Jaemoon Lee
DKDae Hee Kim
Dae Hee Kim
We evaluated the performance of the McGrath video laryngoscope and Pentax Airway Scope in comparison with the Macintosh laryngoscope for nasotracheal intubation in paediatric patients. For this, 108 patients were enrolled in an open-label, randomized controlled trial. Patients were randomly allocated to one of three groups based on use of the Macintosh laryngoscope, McGrath video laryngoscope, or Pentax Airway Scope. Time to intubation, the intubation difficulty, and the quality of navigation were compared among groups. The median nasotracheal intubation time [interquartile range] in the Macintosh group (33.5 [28.3–39.8] s) was significantly shorter than those of the McGrath (39.0 [32.0–43.0] s) and Pentax groups (43.0 [35.0–52.0] s). The difficulty of nasotracheal intubation was similar among all groups. When navigating and aligning the tube from the oropharynx into the glottic inlet, the cuff inflation method was required in significantly fewer patients for the Macintosh group (11.1%) than for the McGrath (48.6%) and Pentax (51.4%) groups. Thus, compared to the McGrath video laryngoscope and Pentax Airway Scope, the Macintosh laryngoscope allowed shorter nasotracheal intubation times and better facilitated tracheal navigation, requiring less use of the cuff inflation method to navigate the tracheal tube into the glottic inlet.

1 October 2018 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
DKDae-Hee Kim
Dae-Hee Kim
JYJi-Young Yoo
Ji-Young Yoo
JKJong-Yeop Kim
Jong-Yeop Kim
SASoo-Hwan Ahn
Soo-Hwan Ahn
SKSeongsu Kim
Seongsu Kim
SMSangkee Min
Sangkee Min
Hypnosis monitors analyze small-amplitude electrical signals transmitted from the brain that could be exposed to the electromagnetic field that occurs around the body during electrocautery (ECT). We investigated the influence of ECT on hypnosis monitoring during anesthesia. We simultaneously monitored BIS and uCON during 50 gynecologic oncology surgeries. During the episodes of ECT, we compared the absolute difference (a-Diff) between the baseline index and the most deviated index after ECT over either 30-60 s (ECT30-60) or more than 60 s (ECT > 60) between the monitors. We also investigated the bias and the limits of agreement between the monitors. Between the two monitors, the a-Diff of ECT30-60 was 1.4 ± 1.1 for the BIS, which was significantly greater than 0.6 ± 0.9 for the uCON (P = 0.003), and the a-Diff of ECT > 60 was 16.5 ± 8.2 for the BIS, which was also significantly greater than 1.4 ± 1.3 for uCON (P < 0.001). The intra-monitor index differences showed that the BIS during ECT > 60 was significantly greater than that during ECT30-60 (P < 0.001), but the uCON showed no significant difference between ECT30-60 and ECT > 60 (P = 0.056). The estimated bias between the monitors was 6.3 ± 9.8 and 95% limits agreement was -12.3 to 25.0. Prolonged ECT intervention might lead to spurious estimations of quantitative EEG indexes. Therefore, hypnosis should be clinically assessed in combination with scrutinized judgment of relevant clinical symptoms and signs for hypnosis.

1 August 2023 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
SKSeyoon Kang
Seyoon Kang
YCYun jeong Chae
Yun jeong Chae
DKDae Hee Kim
Dae Hee Kim
TKTaek Geun Kim
Taek Geun Kim
JYJi Young Yoo
Ji Young Yoo
Background: Direct insertion of a double-lumen tube (DLT) using a flexible fiberoptic bronchoscope (FOB) is an option for DLT intubation. The difficult process of fiberoptic intubation is that the different properties of polyvinyl chloride and silicone DLTs may affect railroading differently. Therefore, we aimed to compare intubation using polyvinyl chloride and silicone DLTs over an FOB. Methods: Patients aged 19–75 years who required one-lung ventilation under general anesthesia were enrolled in this study. After induction of anesthesia, the anesthesiologist intubated the DLT using FOB. The primary outcome was the difficulty of railroading over the flexible FOB scaled into five grades (I, II-1, II-2, III, and IV). Additionally, the intubation time and mucosal damage were recorded.Results: A total of 46 patients participated in this study, 23 each in the silicone and polyvinyl groups. The difficulty of railroading over the FOB was significantly different between the two groups (P < 0.001). In the silicone group, the grades of difficulty in railroading were limited to I and II-1; 20 patients (87%) presented no difficulty in advancing the tube. In contrast, in the polyvinyl group, 13 patients (57%) had scores of II-2 and III. Both the intubation time and mucosal damage were significantly better in the silicone group than in the polyvinyl group.Conclusions: Intubation using a silicone DLT over an FOB was easier and faster than that with a polyvinyl chloride DLT with lesser trauma around the glottis.