12 January 2015 in Advanced Materials
6 December 2017 in Science Translational Medicine
Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N-isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat–induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries.
1 January 2011 in Journal of the Electrochemical Society
An efficient platinum-iridium thin film alloy electrodeposition method has been evaluated to modify the surface of platinum or gold microelectrodes that are being developed for neural recording and stimulation applications. A large number of electrodeposition process variables have been investigated in terms of how they affected the properties of the electrodeposited films. Three sets of Pt-Ir films of a certain composition were electroplated on gold substrates using a potential cycling technique and characterized using microscopy, elemental analysis, nanoindentation, and electrochemical techniques to evaluate the repeatability of the electrodeposition process. Deposition rates were estimated by determining film mass and thickness as a function of deposition time. The surface morphology of the Pt-Ir films was characterized using scanning electron microscopy (SEM) and the chemical composition was determined using wavelength dispersive spectroscopy (WDS). Nanoindentation measurements showed that the hardness of the electroplated Pt-Ir thin films was nearly 100% higher than that of a Pt foil. The electrochemical properties of the films were evaluated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and compared with those of pure Pt, pure Ir and 80–20% Pt-Ir foils. The final electroplating process resulted in 60–40% Pt-Ir alloys. The film thickness increased with electrodeposition time at a rate of 16.5 nm/min and stable films with up to 500 nm thickness were obtained. Characterization by SEM and EIS revealed that the real surface area of the Pt-Ir films was much larger than that of pure Pt and increased significantly with increasing deposition time.
1 January 2005 in Journal of the Electrochemical Society
The morphology, microstructure, and electrochemical properties of platinum thin films deposited from aqueous ammonium hexachloroplatinate are dependent on the deposition potential. With increasing overpotential, the grain size increases and the films exhibit stronger (111) texture. Films deposited at low overpotential exhibit very small grain size and a preferred (311) texture. In addition, films deposited at <mml:math display="inline"><mml:mrow><mml:mo>−</mml:mo><mml:mn>0.5</mml:mn></mml:mrow></mml:math>−0.5 and <mml:math display="inline"><mml:mrow><mml:mo>−</mml:mo><mml:mn>0.6</mml:mn><mml:mspace width="0.3em"></mml:mspace><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math>−0.6V are porous with very high surface areas. The electrochemical response of the films is dependent on the morphology and microstructure.
14 March 2008 in IEEE Transactions on Biomedical Engineering
As microelectrodes gain widespread use for electrochemical sensing, biopotential recording, and neural stimulation, it becomes important to understand the dependence of electrochemical impedance on microelectrode size. It has been shown mathematically that a disc electrode, coplanar in an insulating substrate and exposed to a conducting media, exhibits an inhomogeneous current distribution when a potential step is applied. This distribution is known as the primary distribution, and its derivation also yielded an analytic solution for electrical resistance of the conducting media (Rs), between the disc surface and a distant ground, which is inversely proportional to disk radius [Rs = 1/(4Kr), where k is media conductivity and r is disk radius]. The dependence of spectral impedance on microelectrode radius, however, has not been explored. We verify the analytical solution for resistance using high-frequency (100 kHz) electrochemical impedance data from microelectrodes of varying radius (11-325 mum). For all disc radii, as we approach a lower frequency (rarr 10 Hz), we observe a transition from radial to area dependence (e.g., 1/r rarr 1/r2). We hypothesize that this transition is driven by the fact that the derivation of the primary distribution ignores concentration gradients, but that these gradients cannot be ignored at lower frequencies.