Yuri Hamada

Yuri Hamada

Auto-generated profile, based on publicly available information

Yuri Hamada

Chuo University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2021 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
KNK. Nishio
K. Nishio
TKT. Kaburagi
T. Kaburagi
YHY. Hamada
Y. Hamada
TMT. Matsumoto
T. Matsumoto
SKS. Kumagai
S. Kumagai
YKY. Kurihara
Y. Kurihara
Fall accidents are serious problems, especially for elderly people living alone. This is why many fall event detection methods have been proposed in the past. When constructing multiple classification models, a method is expected to be constructed for every fall and nonfall actions. However, in the context of IoT, it would be challenging, if not impossible, to cover all scenarios, because it is necessary to keep the computational cost low. Thus, we propose a hidden Markov model that aggregates the actions measured with a single Doppler sensor (based on the likelihood) in each fall and nonfall events. To validate the proposed method, we conducted an experiment with 20 subjects who performed three fall actions and four nonfall actions each. An accuracy of 0.95 was achieved, and the number of generated fall and nonfall detection models was 1:2 and 1:3, respectively. The experiment’s results show that the proposed method has successfully reduced the number of classification models, which is crucial for IoT applications.

9 July 2021 in IEEE Sensors Letters
Verified
Journal Article
Open access
KNKeita Nishio
Keita Nishio
TKTakashi Kaburagi
Takashi Kaburagi
YHYuri Hamada
Yuri Hamada
YKYosuke Kurihara
Yosuke Kurihara
In this paper, we propose a bed-based unconstrained cardiac auscultation method to obtain heart sounds while a person is lying on a bed. In the proposed method, a sensing device with a resonance frequency in the frequency range of heart sounds is designed to improve the decreased gain of heart sounds through propagation in the bed mattress. In addition, the Wiener filter is applied to reduce the noise component contained in the measurement signals obtained by the proposed device. We performed a validation experiment to evaluate whether the proposed method correctly measures heart sounds by comparing the reference heart sounds measured by a stethoscope and those by the proposed device under a combination of conditions with different bed mattress thicknesses, sleeping postures, and respiratory states. The accuracy is evaluated by the correlation coefficient of the spectrum of heart sounds between the proposed method and the stethoscope. The experimental results demonstrate that the proposed unconstrained cardiac auscultation method can measure heart sounds with a correlation coefficient of 0.75 0.12 on average.

25 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TYT. Yoshida
T. Yoshida
YHY. Hamada
Y. Hamada
SNSousuke Nakamura
Sousuke Nakamura
YKY. Kurihara
Y. Kurihara
KWK. Watanabe
K. Watanabe
This paper describes a method to monitor lung disorders such as the sequelae of the novel coronavirus (SARS-CoV2) and asthma. A battery-less spirometer sensor element used in microphone-equipped devices such as smartphones was adopted. A vortex whistle was employed to measure the blowing flow rate and pressure. The physical characteristics of the vortex whistle sound frequency, blowing flow rate, blowing pressure, and sound pressure were theoretically clarified. Moreover, the structural conditions necessary to ensure a high performance of the whistle were experimentally derived, and the theoretically derived characteristics were experimentally validated using an actual whistle. The experimental results and theoretically derived characteristics were in agreement, and the sound frequency was noted to be linearly proportional to the flow rate. Furthermore, the sound pressure increased to +40 dB / decade as the frequency increased, and the outlet pressure was proportional to the square of the frequency. On the basis of these results, the signal processing conditions to acquire the information pertaining to the spirometer from the vortex sound were clarified.

22 September 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YHY. Hamada
Y. Hamada
TYT. Yoshida
T. Yoshida
YKY. Kurihara
Y. Kurihara
KWK. Watanabe
K. Watanabe
This paper describes a novel application of a piezoelectric sounder on an acoustic device as a respiratory detector. When human exhaled air at a temperature of 36.5 ° C is blown onto the piezoelectric device in the sounder in a room of 26.4 ° C, a peak voltage of 1–2 V directly appears without an amplifier. We herein present a theoretical model of how the device works, experimentally prove its validity, and show its potential to be used as a spirometry detector. The output voltage changes alongside the output of a medical spirometer for forced vital capacity test respiration. The device is noise robust under a variety of measurement conditions, including different masks, shields, snorkels, sustained airway positive pressure devices. The S/N ratios for quiet sitting, walking, quick face swing, and mask movement were 38 dB, 33.3 dB, 32.3 dB, and 30.9 dB, respectively. The piezoelectric sounder considered herein can return to the original function and generate an alarm if the measured reparation is abnormal.

17 November 2020 in IEEE Access
Verified
Journal Article
Open access
YKYosuke Kurihara
Yosuke Kurihara
TKTakashi Kaburagi
Takashi Kaburagi
KNKeita Nishio
Keita Nishio
YHYuri Hamada
Yuri Hamada
TMToshiyuki Matsumoto
Toshiyuki Matsumoto
SKSatoshi Kumagai
Satoshi Kumagai
In cognitive task execution, retrieval processes transfer memories from long-term storage to working memory, comprising three short-term memories—phonological loop, visuospatial sketchpad, and episodic buffer—controlled by a short-term-memory central executive. The phonological loop and visuospatial sketchpad are prominent in verbal and visuospatial information processing, respectively. Individuals differ in how they retrieve the same information. Discrimination between verbal or visuospatial memory retrieval by monitoring central executive activation is useful. Functional near-infrared spectroscopy (fNIRS) was used to assess blood volume and prefrontal lobe brain activation. Using a novel approach, blood volume during memory retrieval was obtained using fNIRS. To eliminate other factors not related to the central executive activation, a base period was observed. Dynamic range was calculated for both memory retrieval and base periods, and differences obtained at ten positions within the prefrontal lobe were used as features to discriminate between verbal and visuospatial retrieval. For discrimination, k-nearest neighbor (kNN) and support vector machine (SVM) with different kernels were applied. Our method was tested on participants in verbal/visuospatial memory retrieval experiments. As the result, accuracy, positive predictive values, and negative predictive values of kNN and SVM were 1, which indicated that the proposed method successfully discriminated between verbal/visuospatial memory retrieval through prefrontal lobe blood volume observation.

28 July 2023 in IEEE Access
Verified
Journal Article
Open access
YHY. Hamada
Y. Hamada
TYT. Yoshida
T. Yoshida
YKY. Kurihara
Y. Kurihara
KWK. Watanabe
K. Watanabe
Liquid food can likely cause accidental ingestion in patients with dysphagia. This study proposes a handheld stirrer-type rotational viscometer that can be used in the kitchen or at meals for dysphagia. A novel rotational viscometer is proposed considering that the rotation speed of the handheld stirrer is inversely proportional to the viscosity of the fluids to be stirred. We adopt the sensorless control strategy. We use a small brush-type DC motor, which functions as a rotary actuator and a rotational speed sensor to realize the proposed device. Because the proposed viscometer is used in the aforementioned fields, it must be compact, handy, simple in structure, and low-cost. We apply the proposed viscometer to fluids with viscosities ranging from 5000 to 54000 mPa·s for testing, using a cylindrical rotor with a length of 15 mm and diameter of 10 mm. The repeatability and linearity as a measurement instrument evaluated by the ASTM standards E3116-18 are less than 5% and 4% for the aforementioned fluids under the temperature of 11 °C, respectively. Because the thickness of liquid food is classified into only three categories (mildly, moderately, and extremely thick), the accuracy of this method is sufficient for the measurement.