31 May 2007 in Laser Physics Letters
1 February 1997 in Journal of Bone and Mineral Research
In recent years, time-resolved spectroscopy systems using near infrared pulsed laser have been applied to develop optical computed tomography. We applied this technique to measure the optical properties of osseous tissue. First, we gradually demineralized 10 mm blocks of bovine trabecular bone with EDTA, maintaining the absorption characteristics and structure but varying the hydroxyapatite content, thus creating specimens differing only in light scattering properties. We used computer densitograms to assess light penetration, and analyzed the correlation with bone mineral density (BMD) as with dual-energy X-ray absorptiometry scans. The light penetration increased with decreasing BMD. Second, using the above-mentioned pulsed laser time-resolved spectroscopy system, we investigated the correlation between the BMD and the time response waveforms of 10-mm blocks of bovine cortical bone, trabecular bone, and surrounding tissue as well as human trabecular bone. The human lumbar vertebral bone also displayed an inverse correlation between BMD and maximum light penetration and a positive correlation between BMD and peak time delay. This is the first demonstration of a correlation between BMD and light scattering properties showing that BMD can indeed be measured with light. Our results show the possibility of obtaining information on internal bone structure and composition in vivo through assessment of the waveforms obtained by a time-resolution system in the near infrared region.
31 May 2011 in Quantum Electronics
1 August 1995 in Optical Review
15 May 2017 in Journal of Physics D: Applied Physics
Different types of endoplasmic oscillatory activity of Physarum polycephalum plasmodium driven by external influences were investigated. Shuttle velocity oscillations of the endoplasm in an isolated plasmodium strand have been analysed using short-time Fourier (STFT) and wavelet transform. Spectral characteristics calculated from the obtained data allowed us to reveal two internal harmonic oscillators with frequencies differing twice with high accuracy (~2%), or one oscillator in which the frequency doubled with the phase shift. The amplitudes and phases of these harmonics only determine contractile activity, self-organisation and migration of the strand. Inhibitors of the cellular respiration (KCN-SHAM) were applied to demonstrate the interrelation between respiratory pathways with contractile activity. Both internal oscillators showed high sensitivity to the respiratory inhibitors: fast cessation of oscillation in the presence of inhibitors and gradual recovery when they have been removed.
27 June 2012 in Quantum Electronics