The performance of a Pelton wheel is influenced by the jet created by the nozzle. Therefore, a Computational Fluid Dynamics (CFD) simulation was proposed. In this study, the significant output parameters (outlet velocity, outlet pressure, and tangential force component) and input parameters (different pressure and spear locations) were examined. In addition, the influencing parameters and their contributing percentages to the performance of the Pelton wheel were calculated using different optimisation techniques such as Taguchi Design of Experiments (DoE), Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS), Grey Relational Analysis (GRA) and Criteria Importance Through Intercriteria Correlation (CRITIC). The effect of input factors on the output response was examined with DoE, and the results show that the inlet pressure had the most significant impact (97.38%, 99.18%, and 97.38%, respectively, for all different spear sites with a 99% confidence level). In terms of preference values, the TOPSIS and GRA results are comparable (best ranks for simulation runs #24 and #25 and least ranks for simulations #2 and #3, respectively). The CRITIC results for the pressure parameter are in good agreement with the Taguchi ANOVA analysis. The last spear location (5 mm after the nozzle outlet), with an inlet pressure of 413685 Pa generated the best result when employing the TOPSIS and GRA techniques. The outlet pressure of the nozzle was found to have a significant impact on the flow pattern of the Pelton Wheel based on the analysis of the CRITIC, Taguchi, and CFD results.
28 June 2011 in International Journal of Energy Sector Management
Purpose: The purpose of this study is to examine the electricity consumption trend in residential buildings using incandescent lamps and retrofitting with compact fluorescent lamps (CFLs).Design/methodology/approach: Questionnaires were administered to capture the necessary data from three randomly selected residential estates in Ilorin, Nigeria. In total, 8,840 sampled incandescent lamps were retrofitted with CFLs. The electric energy in kilowatt hour (kWh) consumed prior to replacement for three months was compared with kWh consumption after retrofitting and analyzed employing t‐tests.Findings: The three‐month average electricity consumption of ten households for the University of Ilorin GRA quarters and Lower Niger River Basin staff quarters pre‐ and post‐installation were 20,259 and 13,010 kWh, and 46,891 and 29,588 kWh, respectively. Results show that there were significant differences between the observed and tabulated values for the pre‐ and post‐installation of CFLs, respectively, at 5 per cent confidence level. About 40 per cent reduction in electricity consumption was achieved through deployment of CFLs in the residential households.Originality/value: This paper demonstrates how retrofitting of incandescent lamps with CFLs can bring about possible reduction in electricity consumption in residential households in Nigeria.