Christophe Nioche

Christophe Nioche

Auto-generated profile, based on publicly available information

Christophe Nioche

IMIV, CEA, Inserm, CNRS, Université Paris-Sud, Université Paris-Saclay, CEA-SHFJ, Orsay, France

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Radiology
Verified
Journal Article
Closed access
AZAlex Zwanenburg
Alex Zwanenburg
MVMartin Vallières
Martin Vallières
MAMahmoud A. Abdalah
Mahmoud A. Abdalah
HAHugo J. W. L. Aerts
Hugo J. W. L. Aerts
VAVincent Andrearczyk
Vincent Andrearczyk
SLSteffen Löck
Steffen Löck
The Image Biomarker Standardization Initiative validated consensus-based reference values for 169 radiomics features, thus enabling calibration and verification of radiomics software. Background Radiomic features may quantify characteristics present in medical imaging. However, the lack of standardized definitions and validated reference values have hampered clinical use. Purpos...

14 August 2018 in Cancer Research
Verified
Journal Article
Closed access
PDF file
CNChristophe Nioche
Christophe Nioche
FOFanny Orlhac
Fanny Orlhac
SBSarah Boughdad
Sarah Boughdad
SRSylvain Reuzé
Sylvain Reuzé
JGJessica Goya-Outi
Jessica Goya-Outi
IBIrene Buvat
Irene Buvat
Textural and shape analysis is gaining considerable interest in medical imaging, particularly to identify parameters characterizing tumor heterogeneity and to feed radiomic models. Here, we present a free, multiplatform, and easy-to-use freeware called LIFEx, which enables the calculation of conventional, histogram-based, textural, and shape features from PET, SPECT, MR, CT, and US images, or from any combination of imaging modalities. The application does not require any programming skills and was developed for medical imaging professionals. The goal is that independent and multicenter evidence of the usefulness and limitations of radiomic features for characterization of tumor heterogeneity and subsequent patient management can be gathered. Many options are offered for interactive textural index calculation and for increasing the reproducibility among centers. The software already benefits from a large user community (more than 800 registered users), and interactions within that community are part of the development strategy. Significance: This study presents a user-friendly, multi-platform freeware to extract radiomic features from PET, SPECT, MR, CT, and US images, or any combination of imaging modalities. Cancer Res; 78(16); 4786–9. ©2018 AACR.

1 April 2019 in Radiology
Verified
Journal Article
Open access
FOFanny Orlhac
Fanny Orlhac
FFFrédérique Frouin
Frédérique Frouin
CNChristophe Nioche
Christophe Nioche
NANicholas Ayache
Nicholas Ayache
IBIrene Buvat
Irene Buvat
Background Radiomics extracts features from medical images more precisely and more accurately than visual assessment. However, radiomics features are affected by CT scanner parameters such as reconstruction kernel or section thickness, thus obscuring underlying biologically important texture features. Purpose To investigate whether a compensation method could correct for the variations of radiomic feature values caused by using different CT protocols. Materials and Methods Phantom data involving 10 texture patterns and 74 patients in cohorts 1 (19 men; 42 patients; mean age, 60.4 years; September-October 2013) and 2 (16 men; 32 patients; mean age, 62.1 years; January-September 2007) scanned by using different CT protocols were retrospectively included. For any radiomic feature, the compensation approach identified a protocol-specific transformation to express all data in a common space that were devoid of protocol effects. The differences in statistical distributions between protocols were assessed by using Friedman tests before and after compensation. Principal component analyses were performed on the phantom data to evaluate the ability to distinguish between texture patterns after compensation. Results In the phantom data, the statistical distributions of features were different between protocols for all radiomic features and texture patterns (P < .05). After compensation, the protocol effect was no longer detectable (P > .05). Principal component analysis demonstrated that each texture pattern was no longer displayed as different clusters corresponding to different imaging protocols, unlike what was observed before compensation. The correction for scanner effect was confirmed in patient data with 100% (10 of 10 features for cohort 1) and 98% (87 of 89 features for cohort 2) of P values less than .05 before compensation, compared with 30% (three of 10) and 15% (13 of 89) after compensation. Conclusion Image compensation successfully realigned feature distributions computed from different CT imaging protocols and should facilitate multicenter radiomic studies. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Steiger and Sood in this issue.

4 January 2018 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
FOFanny Orlhac
Fanny Orlhac
SBSarah Boughdad
Sarah Boughdad
CPCathy PHILIPPE
Cathy PHILIPPE
HSHugo Stalla-Bourdillon
Hugo Stalla-Bourdillon
CNChristophe Nioche
Christophe Nioche
IBIrene Buvat
Irene Buvat
Introduction: Several reports have shown that radiomic feature values are affected by the acquisition and reconstruction parameters, thus hampering multicenter studies. We propose a method to standardize features measured from Positron Emission Tomography (PET) images obtained using different imaging protocols to remove the center effect while preserving patient-specific effects. Methods: Pre-treatment 18F-FDG-PET images of patients with breast cancer were included. In Department A, 63 patients were scanned using a Gemini Time-Of-Flight-PET/Computed-Tomography scanner including 16 triple-negative lesions (TN). In Department B, 74 patients underwent a PET on a GE Discovery 690 Scanner including 15 TN lesions. PET images from Department A were also smoothed using a Gaussian filter to mimic data from a third Department called Department A-S. The primary tumor was segmented to get a tumor volume of interest (VOI) and a spherical VOI was also set in healthy liver tissue. Three Standardized Uptake Values (SUVs) and 6 textural features were computed in all VOI using LIFEx software. A harmonization method, ComBat, initially described for genomic data, was used to estimate the department effect based on the observed feature values. Feature distributions in each department were compared before and after harmonization. Results: In healthy liver tissue, the feature distributions were significantly different for 4 out of 9 features between Departments A and B, and for 6 out of 9 between Departments A and A-S (p0.1). The same trend was observed in tumors with a realignment of feature values between the departments after ComBat. Identification of TN lesions was largely enhanced after harmonization when the cut-off values were determined on data from one department and applied to data from the other department. Conclusion: ComBat is efficient at removing the multicenter effect for textural features and SUVs. The method is easy to use, retains biological variations not related to a center effect, and does not require any feature recalculation. Such a harmonization allows for multicenter studies, external validation of radiomic models or cut-off values, and should facilitate the use of radiomic models in clinical practice.

1 February 2024 in Radiology
Verified
Journal Article
Closed access
PWPhilip Whybra
Philip Whybra
AZAlex Zwanenburg
Alex Zwanenburg
VAVincent Andrearczyk
Vincent Andrearczyk
RSRoger Schaer
Roger Schaer
AAAditya P. Apte
Aditya P. Apte
ADAdrien Depeursinge
Adrien Depeursinge
Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.

1 February 2003 in NeuroImage
Verified
Journal Article
Closed access
PSP Sabbah
P Sabbah
FCF Chassoux
F Chassoux
CLC Leveque
C Leveque
ELE Landre
E Landre
SBS Baudoin-Chial
S Baudoin-Chial
YCY.S Cordoliani
Y.S Cordoliani