1 July 2019 in Journal of Biomechanics
1 May 2021 in Journal of Biomechanics
JNJosien C. van Den Noort
+3
Movement of skin markers with respect to their underlying bone (i.e. soft tissue artifacts (STAs)) might corrupt the accuracy of marker-based movement analyses. This study aims to quantify STAs in 3D for foot markers and their effect on multi-segment foot kinematics as calculated by the Oxford and Rizzoli Foot Models (OFM, RFM). Fifteen subjects with asymptomatic feet were seated on a custom-made loading device on a computed tomography (CT) table, with a combined OFM and RFM marker set on their right foot. One unloaded reference CT-scan with neutral foot position was performed, followed by 9 loaded CT-scans at different foot positions. The 3D-displacement (i.e. STA) of each marker in the underlying bone coordinate system between the reference scan and other scans was calculated. Subsequently, segment orientations and joint angles were calculated from the marker positions according to OFM and RFM definitions with and without STAs. The differences in degrees were defined as the errors caused by the marker displacements. Markers on the lateral malleolus and proximally on the posterior aspect of the calcaneus showed the largest STAs. The hindfoot-shank joint angle was most affected by STAs in the most extreme foot position (40° plantar flexion) in the sagittal plane for RFM (mean: 6.7°, max: 11.8°) and the transverse plane for OFM (mean: 3.9°, max: 6.8°). This study showed that STAs introduce clinically relevant errors in multi-segment foot kinematics. Moreover, it identified marker locations that are most affected by STAs, suggesting that their use within multi-segment foot models should be reconsidered.
1 October 2020 in Gait & Posture
JNJosien C. van Den Noort
MKMarjolein M. van der Krogt
Marjolein M. van der Krogt
+2
The Oxford Foot Model (OFM) and Rizzoli Foot Model (RFM) are the two most frequently used multi-segment models to measure foot kinematics. However, a comprehensive comparison of the kinematic output of these models is lacking. What are the differences in kinematic output between OFM and RFM during normal gait and typical pathological gait patterns in healthy adults?. A combined OFM and RFM marker set was placed on the right foot of ten healthy subjects. A static standing trial and six level walking trials were collected for normal gait and for four voluntarily adopted gait types: equinus, crouch, toe-in and toe-out. Joint angles were calculated for every trial for the hindfoot relative to shank (HF-SH), forefoot relative to hindfoot (FF-HF) and hallux relative to forefoot (HX-FF). Average static joint angles of both models were compared between models. After subtracting these offsets, the remaining dynamic angles were compared using statistical parametric mapping repeated measures ANOVAs and t-tests. Furthermore, range of motion was compared between models for every angle. For the static posture, RFM compared to OFM measured more plantar flexion (Δ = 6°) and internal rotation (Δ = 7°) for HF-SH, more plantar flexion (Δ = 34°) and inversion (Δ = 13°) for FF-HF and more dorsal flexion (Δ = 37°) and abduction (Δ = 12°) for HX-FF. During normal walking, kinematic differences were found in various parts of the gait cycle. Moreover, range of motion was larger in the HF-SH for OFM and in FF-HF and HX-FF for RFM. The differences between models were not the same for all gait types. Equinus and toe-out gait demonstrated most pronounced differences. Differences are present in kinematic output between OFM and RFM, which also depend on gait type. Therefore, kinematic output of foot and ankle studies should be interpreted with careful consideration of the multi-segment foot model used.
7 June 2022 in Journal of Foot and Ankle Research
JNJosien C. van Den Noort
+1
Background: Foot and ankle joint kinematics are measured during clinical gait analyses with marker‐based multi‐segment foot models. To improve on existing models, measurement errors due to soft tissue artifacts (STAs) and marker misplacements should be reduced. Therefore, the aim of this study is to define a clinically informed, universally applicable multi‐segment foot model, which is developed to minimize these measurement errors.Methods: The Amsterdam foot model (AFM) is a follow‐up of existing multi‐segment foot models. It was developed by consulting a clinical expert panel and optimizing marker locations and segment definitions to minimize measurement errors. Evaluation of the model was performed in three steps. First, kinematic errors due to STAs were evaluated and compared to two frequently used foot models, i.e. the Oxford and Rizzoli foot models (OFM, RFM). Previously collected computed tomography data was used of 15 asymptomatic feet with markers attached, to determine the joint angles with and without STAs taken into account. Second, the sensitivity to marker misplacements was determined for AFM and compared to OFM and RFM using static standing trials of 19 asymptomatic subjects in which each marker was virtually replaced in multiple directions. Third, a preliminary inter‐ and intra‐tester repeatability analysis was performed by acquiring 3D gait analysis data of 15 healthy subjects, who were equipped by two testers for two sessions. Repeatability of all kinematic parameters was assessed through analysis of the standard deviation (σ) and standard error of measurement (SEM).Results: The AFM was defined and all calculation methods were provided. Errors in joint angles due to STAs were in general similar or smaller in AFM (≤2.9°) compared to OFM (≤4.0°) and RFM (≤6.7°). AFM was also more robust to marker misplacement than OFM and RFM, as a large sensitivity of kinematic parameters to marker misplacement (i.e. > 1.0°/mm) was found only two times for AFM as opposed to six times for OFM and five times for RFM. The average intra‐tester repeatability of AFM angles was σ:2.2[0.9°], SEM:3.3 ± 0.9° and the inter‐tester repeatability was σ:3.1[2.1°], SEM:5.2 ± 2.3°.Conclusions: Measurement errors of AFM are smaller compared to two widely‐used multi‐segment foot models. This qualifies AFM as a follow‐up to existing foot models, which should be evaluated further in a range of clinical application areas.
1 March 2020 in Gait & Posture