Robert Copperwhite

Robert Copperwhite

Auto-generated profile, based on publicly available information

Robert Copperwhite

Optical Sensors Laboratory, National Centre for Sensor Research, Dublin City University, Glasnevin, Ireland

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2011 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
RCRobert Copperwhite
Robert Copperwhite
MOMary O’sullivan
Mary O’sullivan
CBCatherine Boothman
Catherine Boothman
AGArnaud Gorin
Arnaud Gorin
CMColette McDonagh
Colette McDonagh
MOMohamed Oubaha
Mohamed Oubaha

19 May 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RCRobert Copperwhite
Robert Copperwhite
MOmohamed oubaha
mohamed oubaha
JMJohn Moore
John Moore
CMColette McDonagh
Colette McDonagh
BMBrian D. MacCraith
Brian D. MacCraith
This paper focuses on characterization of the sensing performance of a refractometric sensing platform based on multimode interference couplers (MMICs). Platform fabrication exploited a low-cost process using photocurable organic-inorganic hybrid sol-gel materials which were structured to form optical waveguides by direct UV laser writing. The sensing principle is based upon the high sensitivity of the optical field distribution formed in the MMIC toward changes in the refractive index of its environment. Simulations demonstrated the importance of correctly specifying the length of the MMIC section and illustrated that longer platforms are more sensitive due to a greater shift in self-image position. To characterize sensing performance, a porous sol-gel humidity sensing enrichment layer was coated on the MMIC. Relative humidity was detected by the system with a resolution of 0.097%. Refractive index resolution of the platform was determined to be ~ 2 × 10 -6 RIU , which is an analyte-independent value and illustrates the generic nature of this platform. As such, this platform has immense potential for future applications as a label-free and real-time biosensor platform.

9 November 2005
Verified
Conference Paper
Closed access
RCRobert Copperwhite
Robert Copperwhite
GTGr Town
Gr Town
KKKada-Raphael Kribich
Kada-Raphael Kribich
MOmohamed oubaha
mohamed oubaha
JHJan Hradil
Jan Hradil
BMBrian D. MacCraith
Brian D. MacCraith
Simulations and experimental results for novel refractometric-sensing platforms are presented here. The first platform is based on a multi-mode interference coupler (MMIC) in which the top and sidewalls of the coupler are exposed to a humidity-sensing enrichment layer. Sensor operation is based on the creation of self-images of the input field into the coupler, at regular intervals along the coupler. This phenomenon is due to interference between the optical modes in MMICs. Changes in the refractive index of the sensing layer cause predictable shifts in the position of the output image, which in turn affects the amount of light coupled into the output waveguide. Sensitivity enhancement has been demonstrated by fabricating longer MMICs capturing higher-ranking self-images, which are shifted more than the first self-image. Consequently, more significant changes in the amount of light coupled to the output are observed for a given refractive index change. The second platform demonstrated is a Multi-Channel Directional Coupler sensor (MCDC). It differs from the MMIC in that the sensing region now consists of multiple single-mode waveguides, which are in close enough proximity to allow light to transfer between the waveguides. Sensitivity dependance on platform length has been investigated and compared with that of the MMIC. The devices have been fabricated by the direct laser writing process on UV curable hybrid sol-gel materials. Such materials allow implementation of planar technology enabling integration on a silicon substrate. Future applications of these platforms include chemical and bio-chemical sensing is the areas of process, environmental and bio-diagnostic monitoring.