Sepehr Moghaddam

Sepehr Moghaddam

Auto-generated profile, based on publicly available information

Sepehr Moghaddam

Physiology Research Center Iran University of Medical Sciences Tehran Iran

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2026 in Hong Kong Journal of Emergency Medicine
Verified
Journal Article
Open access
PDF file
APAmirreza Peyrovinasab
Amirreza Peyrovinasab
SMSepehr Moghaddam
Sepehr Moghaddam
MJMahrokh Janmohamadi
Mahrokh Janmohamadi
PSPardis Soroush
Pardis Soroush
SSSaeid Safari
Saeid Safari
MYMahmoud Yousefifard
Mahmoud Yousefifard
Background: Traumatic brain injury (TBI) frequently results in increased intracranial pressure (ICP), which may cause irreversible damage or fatality if not addressed. Prompt and precise detection of ICP is essential, particularly in emergency situations. Objectives: Ultrasonographic measurement of optic nerve sheath diameter (ONSD) has been suggested as a noninvasive technique for identifying ICP. This study seeks to evaluate the diagnostic accuracy of ONSD through ultrasonography in TBI patients. Methods: An umbrella review was performed in accordance with preferred reporting items for systematic reviews and meta‐analyses guidelines, concentrating on systematic reviews and meta‐analyses that detail diagnostic accuracy metrics for ONSD in TBI patients. Studies were incorporated if they provided data on sensitivity, specificity, or area under the curve (AUC) for ONSD in the detection of ICP. The AMSTAR 2 tool was used to figure out the risk of bias, and random‐effects models were used to put the results together. Results: The combined analysis of 41 incorporated studies, showed that the test was very accurate: it had a sensitivity of 0.89 (95% CI: 0.85–0.92), a specificity of 0.84 (95% CI: 0.80–0.89), and an AUC of 0.94 (95% CI: 0.91–0.95). The diagnostic odds ratio was 46 (95% CI: 26–81). Subgroup analyses demonstrated consistency among ONSD cut‐off values and ICP thresholds, notwithstanding significant heterogeneity. Conclusions: Ultrasonography measurement of ONSD shows that it is very accurate for finding high ICP in TBI patients. It offers a dependable, noninvasive screening instrument, especially in emergency contexts. Nevertheless, standardized measurement protocols and additional research are essential to enhance diagnostic thresholds.