Sarah Hashemi Astaneh

Sarah Hashemi Astaneh

Auto-generated profile, based on publicly available information

Sarah Hashemi Astaneh

Department of Chemical Engineering, University of Illinois Chicago, Chicago, IL 60612, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2019 in Crystals
Verified
Journal Article
Open access
PDF file
SSSharif Shahbeyk
Sharif Shahbeyk
George VoyiadjisGeorge Voyiadjis
George Voyiadjis
VHVahid Habibi
Vahid Habibi
SASarah Hashemi Astaneh
Sarah Hashemi Astaneh
MYMohammadreza Yaghoobi
Mohammadreza Yaghoobi
The micropillar compression test is a novel experiment to study the mechanical properties of materials at small length scales of micro and nano. The results of the micropillar compression experiments show that the strength of the material depends on the pillar diameter, which is commonly termed as size effects. In the current work, first, the experimental observations and theoretical models of size effects during micropillar compression tests are reviewed in the case of crystalline metals. In the next step, the recent computer simulations using molecular dynamics are reviewed as a powerful tool to investigate the micropillar compression experiment and its governing mechanisms of size effects.

Verified
Journal Article
Open access
PDF file
LFLeonardo Faverani
Leonardo Faverani
SASarah Hashemi Astaneh
Sarah Hashemi Astaneh
Monique Gonçalves da CostaMonique Gonçalves da Costa
Monique Gonçalves da Costa
LDLeonardo Alan Delanora
Leonardo Alan Delanora
TLTiburtino J. Lima-Neto
Tiburtino J. Lima-Neto
Cortino SukotjoCortino Sukotjo
Cortino Sukotjo
The membranes used in bone reconstructions have been the object of investigation in the field of tissue engineering, seeking to improve their mechanical strength and add other properties, mainly the osteopromotive. This study aimed to evaluate the functionalization of collagen membranes, with atomic layer deposition of TiO2 on the bone repair of critical defects in rat calvaria and subcutaneous biocompatibility. A total of 39 male rats were randomized into four groups: blood clot (BC), collagen membrane (COL), COL 150—150 cycles of titania, and COL 600—600 cycles of titania. The defects were created in each calvaria (5 mm in diameter) and covered according to each group; the animals were euthanized at 7, 14, and 28 days. The collected samples were assessed by histometric (newly bone formed, soft tissue area, membrane area, and residual linear defect) and histologic (inflammatory cells and blood cells count) analysis. All data were subjected to statistical analysis (p < 0.05). The COL150 group showed statistically significant differences compared to the other groups, mainly in the analysis of residual linear defects (1.5 ± 0.5 × 106 pixels/µm2 for COL 150, and around 1 ± 0.5 × 106 pixels/µm2 for the other groups) and newly formed bone (1500 ± 1200 pixels/µm for COL 150, and around 4000 pixels/µm for the others) (p < 0.05), demonstrating a better biological behavior in the chronology of defects repair. It is concluded that the collagen membrane functionalized by TiO2 over 150 cycles showed better bioactive potential in treating critical size defects in the rats’ calvaria.