Alexander J. Daniel

Alexander J. Daniel

Auto-generated profile, based on publicly available information

Alexander J. Daniel

Sir Peter Mansfield Imaging Centre University of Nottingham Nottingham UK

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ADAlexander J. Daniel
Alexander J. Daniel
CBCharlotte E. Buchanan
Charlotte E. Buchanan
TAThomas Allcock
Thomas Allcock
DSDaniel Scerri
Daniel Scerri
ECEleanor F. Cox
Eleanor F. Cox
SFSusan Francis
Susan Francis
Purpose: Total kidney volume (TKV) is an important measure in renal disease detection and monitoring. We developed a fully automated method to segment the kidneys from T2‐weighted MRI to calculate TKV of healthy control (HC) and chronic kidney disease (CKD) patients.Methods: This automated method uses machine learning, specifically a 2D convolutional neural network (CNN), to accurately segment the left and right kidneys from T2‐weighted MRI data. The data set consisted of 30 HC subjects and 30 CKD patients. The model was trained on 50 manually defined HC and CKD kidney segmentations. The model was subsequently evaluated on 50 test data sets, comprising data from 5 HCs and 5 CKD patients each scanned 5 times in a scan session to enable comparison of the precision of the CNN and manual segmentation of kidneys.Results: The unseen test data processed by the 2D CNN had a mean Dice score of 0.93 ± 0.01. The difference between manual and automatically computed TKV was 1.2 ± 16.2 mL with a mean surface distance of 0.65 ± 0.21 mm. The variance in TKV measurements from repeat acquisitions on the same subject was significantly lower using the automated method compared to manual segmentation of the kidneys.Conclusion: The 2D CNN method provides fully automated segmentation of the left and right kidney and calculation of TKV in <10 s on a standard office computer, allowing high data throughput and is a freely available executable.

19 October 2018 in Human Brain Mapping
Verified
Journal Article
Open access
PDF file
ADAlexander J. Daniel
Alexander J. Daniel
JSJames A. Smith
James A. Smith
GSGlyn S. Spencer
Glyn S. Spencer
JJJoão Jorge
João Jorge
RBRichard Bowtell
Richard Bowtell
KMKaren J. Mullinger
Karen J. Mullinger
Simultaneous EEG‐fMRI allows multiparametric characterisation of brain function, in principle enabling a more complete understanding of brain responses; unfortunately the hostile MRI environment severely reduces EEG data quality. Simply eliminating data segments containing gross motion artefacts [MAs] (generated by movement of the EEG system and head in the MRI scanner's static magnetic field) was previously believed sufficient. However recently the importance of removal of all MAs has been highlighted and new methods developed. A systematic comparison of the ability to remove MAs and retain underlying neuronal activity using different methods of MA detection and post‐processing algorithms is needed to guide the neuroscience community. Using a head phantom, we recorded MAs while simultaneously monitoring the motion using three different approaches: Reference Layer Artefact Subtraction (RLAS), Moiré Phase Tracker (MPT) markers and Wire Loop Motion Sensors (WLMS). These EEG recordings were combined with EEG responses to simple visual tasks acquired on a subject outside the MRI environment. MAs were then corrected using the motion information collected with each of the methods combined with different analysis pipelines. All tested methods retained the neuronal signal. However, often the MA was not removed sufficiently to allow accurate detection of the underlying neuronal signal. We show that the MA is best corrected using the RLAS combined with post‐processing using a multichannel, recursive least squares (M‐RLS) algorithm. This method needs to be developed further to enable practical utility; thus, WLMS combined with M‐RLS currently provides the best compromise between EEG data quality and practicalities of motion detection.

21 February 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
HLHao Li
Hao Li
ADAlexander J. Daniel
Alexander J. Daniel
CBCharlotte E. Buchanan
Charlotte E. Buchanan
FNFábio Nery
Fábio Nery
DMDavid M. Morris
David M. Morris
SFSusan Francis
Susan Francis
Background: T2 mapping is valuable to evaluate pathophysiology in kidney disease. However, variations in T2 relaxation time measurements across MR scanners and vendors may occur requiring additional correction.Purpose: To harmonize renal T2 measurements between MR vendor platforms, and use an extended‐phase‐graph‐based fitting method (“StimFit”) to correct stimulated echoes and reduce between‐vendor variations.Study Type: Prospective.Subjects: 8 healthy “travelling” volunteers (37.5% female, 32 ± 6 years) imaged on four MRI systems across three vendors at four sites, 10 healthy volunteers (50% female, 32 ± 8 years) scanned multiple times on a given MR scanner for repeatability evaluation. ISMRM/NIST system phantom scanned for evaluation of T2 accuracy.Field Strength/Sequence: 3T, multiecho spin‐echo sequence.Assessment: T2 images fit using conventional monoexponential fitting and “StimFit.” Mean absolute percentage error (MAPE) of phantom measurements with reference T2 values. Average cortex and medulla T2 values compared between MR vendors, with masks obtained from T2‐weighted images and T1 maps. Full‐width‐at‐half‐maximum (FWHM) T2 distributions to evaluate local homogeneity of measurements.Statistical Tests: Coefficient of variation (CV), linear mixed‐effects model, analysis of variance, student's t‐tests, Bland–Altman plots, P‐value <0.05 considered statistically significant.Results: In the ISMRM/NIST phantom, “StimFit” reduced the MAPE from 4.9%, 9.1%, 24.4%, and 18.1% for the four sites (three vendors) to 3.3%, 3.0%, 6.6%, and 4.1%, respectively. In vivo, there was a significant difference in kidney T2 measurements between vendors using a monoexponential fit, but not with “StimFit” (P = 0.86 and 0.92, cortex and medulla, respectively). The intervendor CVs of T2 measures were reduced from 8.0% to 2.6% (cortex) and 7.1% to 2.8% (medulla) with StimFit, resulting in no significant differences for the CVs of intravendor repeat acquisitions (P = 0.13 and 0.05). “StimFit” significantly reduced the FWHM of T2 distributions in the cortex and whole kidney.Data Conclusion: Stimulated‐echo correction reduces renal T2 variation across MR vendor platforms.Level of Evidence: 2Technical Efficacy: Stage 1

25 September 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
ADAlexander J. Daniel
Alexander J. Daniel
SFSusan Francis
Susan Francis
Background: T 2 ‐mapping has promise to evaluate kidney pathophysiology. Prior studies show a large variance in kidney T 2 , likely due to the differing acquisition sequences. Purpose: To compare four T 2 ‐mapping sequences to investigate kidney T 2 . Study Type: Phantom and prospective in vivo assessments. Participants: ISMRM/NIST and QASPER phantoms; 8 healthy volunteers (4 female, 30 ± 8 years). Field Strength/Sequence: 3 T, spin echo‐echo planar imaging (SE‐EPI), multi‐echo‐spin echo (ME‐SE), Gradient and Spin Echo (GraSE) vendor‐provided sequences, and custom T 2 ‐prepared EPI, Dual‐echo B 0 ‐mapping and DREAM B 1 ‐mapping. Assessment: T 2 ‐mapping accuracy in the ISMRM/NIST phantom in the presence of B 0 frequency offset and B 1 + by scaling of flip angles, and in the QASPER phantom in the presence of diffusion by altering pump rate compared to being turned off. Participants underwent a single 45‐min exam to collect four T 2 ‐mapping sequences, B 0 and B 1 maps. In vivo T 2 values compared across sequences and the influence of B 0 and B 1 + was evaluated. Statistical Tests: Shapiro–Wilk, Wilcoxon signed‐rank, Student's t ‐test, Coefficient of Variation, Pearson's correlation coefficient, linear mixed effect model. p < 0.05 considered statistically significant. Results: SE‐EPI, ME‐SE, GraSE, and T 2 ‐prepared EPI had a mean absolute scaled error of 0.52, 0.52, 0.36, and 0.27 over the kidney T 2 range of the ISMRM/NIST phantom. GraSE was most robust to perturbations in B 0 /B 1 + . In the QASPER phantom, SE‐EPI was highly sensitive to diffusion leading to T 2 shortening (66%), while multi‐echo sequences had lower diffusion sensitivity ordered by shortest echo spacing (ME‐SE 81%, T 2 ‐prepared EPI 90%, GraSE 95% reduction in T 2 ). In vivo, SE‐EPI measured T 2 was significantly lower than multi‐echo sequences, and SE‐EPI and T 2 ‐preparation had a −0.52 ± 0.08 and −0.57 ± 0.06 ms/% dependence on B 1 + . Data Conclusion: To reduce B 0 , B 1 + , and diffusion sensitivity for kidney T 2 ‐mapping, a multi‐echo sequence spanning echo times up to the kidney T 2 (~140 ms at 3 T) is recommended. Collecting data with different echo spacings can isolate the diffusion‐related T 2 component. Evidence Level: 2. Technical Efficacy: Stage 1.

11 July 2025 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
ADAlexander J. Daniel
Alexander J. Daniel
SFSusan Francis
Susan Francis
Quantitative Magnetic Resonance Imaging (qMRI) provides informative measurements of the structure and function of an organ where each volumetric pixel (voxel) provides a measure of the physical properties of the underlying tissue. Traditionally, analysis of MR images is performed by first segmenting the organ and its constituent tissue types, which for the kidneys involves separating them into the cortex and medulla, before calculating the average measurement within each tissue. The process of segmenting renal tissue types is typically manual, making it time consuming and prone to inaccuracies. An alternative to voxel-based analysis in MRI is the layer model which divides the organ into ordered surfaces. For the kidney, this involves generating layers based on the distance of each voxel between the outer and inner surface of the kidney. From this, the gradient of change in qMRI measures between the cortex and medulla of the kidney can be computed to evaluate pathological and physiological aspects of the kidney. Here, 3DQLayers, an open-source Python software package to automatically define and interrogate 3D renal layers is presented.

Verified
Dataset
Open access
ADAlexander J Daniel
Alexander J Daniel
Example kidney segmentation data acquired on a Philips scanner