Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.
We measure the susceptibility components of a poled polymer film by second-harmonic generation with two beams at the fundamental frequency. The technique allows the consistency of experimental data and the validity of the theoretical model used to analyze the results to be addressed. Our results are in agreement with the expected values, provided that the linear optical properties of the sample are properly included.
1 September 2002 in Journal of the Optical Society of America B
We report on our investigation of the potential for all-optical reversible photostructuring of the photochromic molecule 1,2-bis(2-methylbenzo[b]thiophen-3-yl)perfluorocyclopentene (BFCP). The light-induced isomerization of BFCP was studied in solution as well as in polymeric thin films. The absorption change that is due to the photochromic reaction of BFCP was determined by conventional spectroscopic measurements. The absolute values of the refractive indices of doped polymer films were measured by the waveguide grating coupling technique for the two states of the photochromic molecule. The dynamics of the reactions and the light-induced refractive-index changes of doped polymer samples were investigated in holographic grating experiments. Changes of as much as were obtained at 806 nm for 41.16-wt. % doping. Finally, a modified two-beam coupling experiment permitted the separation of absorption and refractive-index contributions to the grating buildup and the determination of the phase shifts of these gratings with respect to the intensity grating.
We present a new technique, based on regression analysis, to determine the second-order nonlinear optical susceptibilitytensor of thin films. The technique does not require the absolute levels or phases of measured signals to be mutually calibrated. In addition it yields indicators that address the quality of theoretical models describing the sample. We use the technique to determine the susceptibilitytensor of samples of a nonracemic chiral material which have very low symmetry (both chiral and anisotropic) and have many independent tensor components. The results show the importance of using detailed theoretical models that account for the linear optical properties of the sample.
Polarized second-harmonic generation using two fundamental beams, instead of one, offers significant advantages for characterizing nonlinear optical thin films. The technique is more precise and allows the internal consistency of the results to be verified. The superiority of the two-beam arrangement over the traditional single-beam arrangement is demonstrated by determining the susceptibility tensors of Langmuir-Blodgett films. We show that, for a well-understood reference sample, the results obtained using two fundamental beams agree qualitatively with those obtained with a single fundamental beam, but are more precise. In a more complicated situation, however, the single-beam technique appears to work well but yields results that are, in fact, incorrect. The two-beam technique, instead, yields clearly inconsistent results, thereby highlighting systematic errors in the experimental arrangement or in the theoretical model used to interpret the results.