YaNan Qu

YaNan Qu

Auto-generated profile, based on publicly available information

YaNan Qu

Institute of Shandong Aerospace Technology, Yantai, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiangQian YU
XiangQian YU
CXChiJie Xiao
ChiJie Xiao
Si LiuSi Liu
Si Liu
Qiugang ZongQiugang Zong
Qiugang Zong
YQYaNan Qu
YaNan Qu
SSSiPei Shao
SiPei Shao
AC vector magnetometers have recently become increasingly widespread. The calibration of AC vector magnetometers before use is critical. Based on traditional ellipsoid fitting, which is suitable for calibrating DC vector magnetometers, a method suitable for calibrating AC vector magnetometers is presented. Simulation analysis and experimental verification demonstrate that this method is effective in calibrating AC vector magnetometers, including scaling factors, angular misalignments and offset errors.

29 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiangQian YU
XiangQian YU
YWYongFu Wang
YongFu Wang
CXChijie Xiao
Chijie Xiao
Si LiuSi Liu
Si Liu
Qiugang ZongQiugang Zong
Qiugang Zong
SSSiPei Shao
SiPei Shao
Magnetic sensor array has become increasingly widespread in use. Because of the manufacturing process, magnetic sensors in an array inevitably experience calibration factor errors. Therefore, the calibration of a magnetic sensor array is very important before use. However, it lacks explicit and quantitative measures on how to calibrate a magnetic sensor array. By using magnetic fields produced by a standard magnetic source at different locations, a practicable method was proposed based on the least-squares method to calibrate a magnetic sensor array. The dimensions of sensor array are about 50×50×50 cm 3 and the level of magnetic field aiming to be measured is ~nT. Both the simulation and experimental results demonstrate that the proposed method is effective in identifying the calibration factor of a magnetic sensor array.

24 March 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
XYXiangQian YU
XiangQian YU
YXYang Xin
Yang Xin
ZHZou Hong
Zou Hong
CHChen HongFei
Chen HongFei
YYYe YuGuang
Ye YuGuang
WYWang YongFu
Wang YongFu
The DDCEM (Deep Dielectric Charging Effects Monitor) that measures the surface leakage currents and the internal charging potentials of the dielectric is equipped on a Chinese medium earth orbit (MEO) navigation satellite to monitor deep dielectric charging risk in real time and research deep dielectric charging effects onboard. In this paper, we focus on the largest observed charging event and take it as an example to discuss the possible applications of the DDCEM data. As expected, the location of the peak currents and potentials values are between 4.4 and 7.7 L-shells. Smaller L-shells mean larger currents and potential variations. Some lag effect (~ minutes) is observed owing to the dielectric charging time constant. Further analysis shows that DDCEM can be used as an onboard conductivity measuring apparatus or an onboard charging electric field monitor. The calculated Flame Retardant 4 (FR4) dielectric top surface’s conductivity σ top (9.1 x 10 –14 S/m ~ 1.5 x 10 –13 S/m) and the bottom surface’s conductivity σ bottom (1.1 x 10 –14 S/m ~ 3.4 x 10 –14 S/m) is much larger than the conductivity (<2.5 x 10 –15 S/m) in NASA (National Aeronautics and Space Administration) -HDBK-4002A [1]. The calculated peak charging electric field near the FR4 dielectric top surface (2.6 x 10 3 V/m ~ 1.2 x 10 4 V/m) and bottom surface (5.5 x 10 3 V/m to 3.1 x 10 4 V/m) is much less than the risk value 10 6 V/m, which is from the ESA (European Space Agency) Final Report [2], means there was no charging risk during the period of this study.