BACKGROUND: Ultrasound based noninvasive techniques for the evaluation of tissue elasticity are becoming popular in practice. An accurate diagnosis of focal liver lesions (FLLs) is very important and essential for the adequate treatment and management of different conditions. AIM: The study aims to evaluate the advantages and limitations of Point Shear Wave Elastography and 2-dimensional Shear Wave Elastography against percutaneous liver biopsy for assessing focal liver lesions. METHODS: This document reviews the advantages and limitations of point shear wave elastography (pSWE) and 2-dimensional shear wave elastography (2D-SWE) against percutaneous liver biopsy for assessing focal liver lesions. RESULTS: Ultrasound elastography has shown promising results and plays an important role in the assessment of focal liver lesions but the lack of histological confirmation is a limitation, especially in cases of suspected FLLs. The Tru cut percutaneous liver biopsy has been proven as a very helpful method for an accurate histological diagnosis. The main disadvantage of this procedure is that is invasive and the complications may be life threatening. CONCLUSION: Noninvasive methods to aid clinical decisions are preferred by patients rather than liver biopsy. US elastography, in the form of pSWE, as well as 2D SWE has proved reliable for the evaluation of liver parenchyma. The investigation of pSWE and 2D-SWE for assessing the elasticity of focal liver lesions and their differentiating is still a challenging goal. Percutaneous liver biopsy provides an option for accurate histological confirmation of liver pathologies, particularly FLLs. It continues to be an important tool in the diagnosis, prognosis, and treatment of those affected with liver disorders.
Background and Objectives: What led to the development of elastography was the emerging need for a method that could objectively and accurately assess the stiffness of internal structures. As a result, a distinction between normal from pathological tissues becomes possible. Objective: To evaluate non-invasive elastographic techniques, point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE), as methods for differentiating simple liver cysts from liver hemangiomas. Materials and Methods—a total of 63 patients—32 with simple liver cysts and 31 with liver hemangiomas were analyzed. The purpose was to determine the values of the average trend (arithmetic mean or median according to the data distribution) as well as the reference intervals of SWV for both methods in the above-mentioned patients. Final diagnoses were confirmed by contrast-enhanced computed tomography (CECT). Results: The pSWE SWV values (median) for simple hepatic cysts showed an average trend of 1.14 m/s, with an upper limit of 3.33 m/s and a lower limit of 0.35 m/s. For 2D-SWE, the average trend for simple hepatic cysts was 1.00 m/s, with an upper limit of 1.54 m/s and a lower limit of 0.65 m/s. For liver hemangiomas, the average trend in pSWE was 1.36 m/s, with an upper limit of 3.22 m/s and a lower limit of 0.57 m/s. For 2D-SWE, the average trend was 1.34 m/s, with an upper limit of 2.27 m/s and a lower limit of 0.80 m/s. Findings in our work mainly serve as reference values. Conclusions: The accurate diagnosis of liver diseases is of paramount importance when it comes to the approach and treatment of individual benign liver lesions. Early diagnosis of focal liver lesions remains a challenging task.