Shuyang Fang

Shuyang Fang

Auto-generated profile, based on publicly available information

Shuyang Fang

Department of Mechanical Engineering, Columbia University, New York, NY, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ELErin Marie Louwagie
Erin Marie Louwagie
LCLindsey Carlson
Lindsey Carlson
VOVeronica Over
Veronica Over
LMLu Mao
Lu Mao
SFShuyang Fang
Shuyang Fang
KMKristin Myers
Kristin Myers
Tissue mechanics is central to pregnancy, during which maternal anatomic structures undergo continuous remodeling to serve a dual function to first protect the fetus in utero while it develops and then facilitate its passage out. In this study of normal pregnancy using biomechanical solid modeling, we used standard clinical ultrasound images to obtain measurements of structural dimensions of the gravid uterus and cervix throughout gestation. 2-dimensional ultrasound images were acquired from the uterus and cervix in 30 pregnant subjects in supine and standing positions at four time points during pregnancy (8-14, 14-16, 22-24, and 32-34 weeks). Offline, three observers independently measured from the images of multiple anatomic regions. Statistical analysis was performed to evaluate inter-observer variance, as well as effect of gestational age, gravity, and parity on maternal geometry. A parametric solid model developed in the Solidworks computer aided design (CAD) software was used to convert ultrasonic measurements to a 3-dimensional solid computer model, from which estimates of uterine and cervical volumes were made. This parametric model was compared against previous 3-dimensional solid models derived from magnetic resonance frequency images in pregnancy. In brief, we found several anatomic measurements easily derived from standard clinical imaging are reproducible and reliable, and provide sufficient information to allow biomechanical solid modeling. This structural dataset is the first, to our knowledge, to provide key variables to enable future computational calculations of tissue stress and stretch in pregnancy, making it possible to characterize the biomechanical milieu of normal pregnancy. This vital dataset will be the foundation to understand how the uterus and cervix malfunction in pregnancy leading to adverse perinatal outcomes.

28 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DFDaniella M. Fodera
Daniella M. Fodera
SRSerena R. Russell
Serena R. Russell
JJJohanna L.L. Jackson
Johanna L.L. Jackson
SFShuyang Fang
Shuyang Fang
XCXiaowei Chen
Xiaowei Chen
KMKristin M. Myers
Kristin M. Myers

21 March 2024 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
SFShuyang Fang
Shuyang Fang
LSLei Shi
Lei Shi
JVJoy-Sarah Y. Vink
Joy-Sarah Y. Vink
HFHelen Feltovich
Helen Feltovich
THTimothy J. Hall
Timothy J. Hall
KMKristin M. Myers
Kristin M. Myers
Cervical remodeling is critical for a healthy pregnancy. Premature tissue changes can lead to preterm birth (PTB), and the absence of remodeling can lead to post-term birth, causing significant morbidity. Comprehensive characterization of cervical material properties is necessary to uncover the mechanisms behind abnormal cervical softening. Quantifying cervical material properties during gestation is challenging in humans. Thus, a nonhuman primate (NHP) model is employed for this study. In this study, cervical tissue samples were collected from Rhesus macaques before pregnancy and at three gestational time points. Indentation and tension mechanical tests were conducted, coupled with digital image correlation (DIC), constitutive material modeling, and inverse finite element analysis (IFEA) to characterize the equilibrium material response of the macaque cervix during pregnancy. Results show, as gestation progresses: (1) the cervical fiber network becomes more extensible (nonpregnant versus pregnant locking stretch: 2.03 ± 1.09 versus 2.99 ± 1.39) and less stiff (nonpregnant versus pregnant initial stiffness: 272 ± 252 kPa versus 43 ± 43 kPa); (2) the ground substance compressibility does not change much (nonpregnant versus pregnant bulk modulus: 1.37 ± 0.82 kPa versus 2.81 ± 2.81 kPa); (3) fiber network dispersion increases, moving from aligned to randomly oriented (nonpregnant versus pregnant concentration coefficient: 1.03 ± 0.46 versus 0.50 ± 0.20); and (4) the largest change in fiber stiffness and dispersion happen during the second trimester. These results, for the first time, reveal the remodeling process of a nonhuman primate cervix and its distinct regimes throughout the entire pregnancy.

31 January 2025 in Acta Biomaterialia
Verified
Journal Article
Closed access
SFShuyang Fang
Shuyang Fang
CDCamilo A. Duarte
Camilo A. Duarte
DFDaniella M. Fodera
Daniella M. Fodera
LSLei Shi
Lei Shi
XCXiaowei Chen
Xiaowei Chen
KMKristin M. Myers
Kristin M. Myers

8 April 2024 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ELErin M. Louwagie
Erin M. Louwagie
DRDivya Rajasekharan
Divya Rajasekharan
AFArielle Feder
Arielle Feder
SFShuyang Fang
Shuyang Fang
CNChia-Ling Nhan-Chang
Chia-Ling Nhan-Chang
KMKristin M. Myers
Kristin M. Myers
Birthing mechanics are poorly understood, though many injuries during childbirth are mechanical, like fetal and maternal tissue damage. Several biomechanical simulation models of parturition have been proposed to investigate birth, but many do not include the uterus. Additionally, most solid models rely on segmenting anatomical structures from clinical images to generate patient geometry, which can be time-consuming. This work presents two new parametric solid modeling methods for generating patient-specific, at-term uterine three-dimensional geometry. Building from an established method of modeling the sagittal uterine shape, this work improves the uterine coronal shape, especially where the fetal head joins the lower uterine wall. Solid models of the uterus and cervix were built from five at-term patients' magnetic resonance imaging (MRI) sets. Using anatomy measurements from MRI-segmented models, two parametric models were created—one that employs an averaged coronal uterine shape and one with multiple axial measurements of the coronal uterus. Through finite element analysis, the two new parametric methods were compared to the MRI-segmented high-fidelity method and a previously published elliptical low-fidelity method. A clear improvement in the at-term uterine shape was found using the two new parametric methods, and agreement in principal Lagrange strain directions was observed across all modeling methods. These methods provide an effective and efficient way to generate three-dimensional solid models of patient-specific maternal uterine anatomy, advancing possibilities for future research in computational birthing biomechanics.

1 October 2021 in Optik
Verified
Journal Article
Closed access
ZHZiqiang He
Ziqiang He
RZRui Zhang
Rui Zhang
SFShuyang Fang
Shuyang Fang
FJFEI JIANG
FEI JIANG