15 May 2015 in Optics Express
The resolution of Single Molecule Localization Microscopy (SML) is dependent on the width of the Point Spread Function (PSF) and the number of photons collected. However, biological samples tend to degrade the shape of the PSF due to the heterogeneity of the index of refraction. In addition, there are aberrations caused by imperfections in the optical components and alignment, and the refractive index mismatch between the coverslip and the sample, all of which directly reduce the accuracy of SML. Adaptive Optics (AO) can play a critical role in compensating for aberrations in order to increase the resolution. However the stochastic nature of single molecule emission presents a challenge for wavefront optimization because the large fluctuations in photon emission do not permit many traditional optimization techniques to be used. Here we present an approach that optimizes the wavefront during SML acquisition by combining an intensity independent merit function with a Genetic algorithm (GA) to optimize the PSF despite the fluctuating intensity. We demonstrate the use of AO with GA in tissue culture cells and through ~50µm of tissue in the Drosophila Central Nervous System (CNS) to achieve a 4-fold increase in the localization precision.
29 March 2023 in Biomedical Optics Express
Optical microscopy is widely used to visualize fine structures. When applied to bioimaging, its performance is often degraded by sample-induced aberrations. In recent years, adaptive optics (AO), originally developed to correct for atmosphere-associated aberrations, has been applied to a wide range of microscopy modalities, enabling high- or super-resolution imaging of biological structure and function in complex tissues. Here, we review classic and recently developed AO techniques and their applications in optical microscopy.
25 May 2021 in Nature Communications
Structured Illumination Microscopy enables live imaging with sub-diffraction resolution. Unfortunately, optical aberrations can lead to loss of resolution and artifacts in Structured Illumination Microscopy rendering the technique unusable in samples thicker than a single cell. Here we report on the combination of Adaptive Optics and Structured Illumination Microscopy enabling imaging with 150 nm lateral and 570 nm axial resolution at a depth of 80 µm throughCaenorhabditis elegans. We demonstrate that Adaptive Optics improves the three-dimensional resolution, especially along the axial direction, and reduces artifacts, successfully realizing 3D-Structured Illumination Microscopy in a variety of biological samples.
1 February 2015 in Journal of Biomedical Optics
Structured illumination microscopy provides twice the linear resolution of conventional fluorescence microscopy, but in thick samples, aberrations degrade the performance and limit the resolution. Here, we demonstrate structured illumination microscopy through 35 µm of tissue using adaptive optics (AO) to correct aberrations resulting in images with a resolution of 140 nm. We report a 60% minimum improvement in the signal-to-noise ratio of the structured illumination reconstruction through thick tissue by correction with AO.
14 January 2010 in Journal of Microscopy