Distributed x-ray radiation dosimetry is crucial in diverse security areas with significant environmental and human impacts such as nuclear waste management, radiotherapy, or radioprotection devices. We present a fast, real-time dosimetry detection system based on flexible oxide thin-film transistors that show a quantitative shift in threshold voltage of up to 3.4 V/gray upon exposure to ionizing radiation. The transistors use indium-gallium-zinc-oxide as a semiconductor and a multilayer dielectric based on silicon oxide and tantalum oxide. Our measurements demonstrate that the threshold voltage shift is caused by the accumulation of positive ionization charge in the dielectric layer due to high-energy photon absorption in the high-Z dielectric. The high mobility combined with a steep subthreshold slope of the transistor allows for fast, reliable, and ultralow-power readout of the deposited radiation dose. The order-of-magnitude variation in transistor channel impedance upon exposure to radiation makes it possible to use a low-cost, passive radiofrequency identification sensor tag for its readout. In this way, we demonstrate a passive, programmable, wireless sensor that reports in real time the excess of critical radiation doses.
The direct detection of 5-MeV protons by flexible organic detectors based on thin films is here demonstrated. The organic devices act as a solid-state detector, in which the energy released by the protons within the active layer of the sensor is converted into an electrical current. These sensors can quantitatively and reliably measure the dose of protons impinging on the sensor both in real time and in integration mode. This study shows how to detect and exploit the energy absorbed both by the organic semiconducting layer and by the plastic substrate, allowing to extrapolate information on the present and past irradiation of the detector. The measured sensitivity, S = (5.15 ± 0.13) pC Gy−1, and limit of detection, LOD = (30 ± 6) cGy s−1, of the here proposed detectors assess their efficacy and their potential as proton dosimeters in several fields of application, such as in medical proton therapy.
25 October 2022 in Advanced Materials Technologies
Organic semiconductors are excellent candidates for X‐ray detectors that can adapt to new applications, with unique properties including mechanical flexibility and the ability to cover large surfaces. Their chemical composition, primarily carbon and hydrogen, makes them human tissue equivalent in terms of radiation absorption. This is a highly desirable property for a radiation dosimeter to be employed in medical diagnostics and therapy, however a low‐Z composition limits the absorption of ionizing radiation. The detection efficiency can be enhanced by considering the photoconductive gain (PG) effect, a significant contributor to the ionizing radiation detection mechanism in this class of materials. In this work, a process of controlled solution deposition by nozzle printing and crystallization of an organic semiconductor thin film is demonstrated whereby a flexible, arrayed thin‐film X‐ray detector with record X‐ray sensitivities among flexible radiation detectors (S = (9.0 ± 0.4) × 107 µC Gy−1 cm−3) is developed. The excitonic peaks responsible for the activation of the PG effect are investigated and identified using a novel technique called photocurrent spectroscopy optical quenching, and the analysis of the changes in trap states is further demonstrated.
A flexible, fully organic detector for proton beams is presented here. The detector operates in the indirect mode and is composed of a polysiloxane-based scintillating layer coupled to an organic phototransistor, that is assessed for flexibility and low-voltage operation (V = −1 V), with a limit of detection of 0.026 Gy min−1. We present a kinetic model able to precisely reproduce the dynamic response of the device under irradiation and to provide further insight into the physical processes controlling it. This detector is designed to target real-time and in-situ dose monitoring during proton therapy and demonstrates mechanical flexibility and low power operation, assessing its potential employment as a personal dosimeter with high comfort and low risk for the patient. The results show how such a proton detector represents a promising tool for real-time particle detection over a large area and irregular surfaces, suitable for many applications, from experimental scientific research to innovative theranostics.
This study reports on a novel, flexible, proton beam detector based on mixed 3D–2D perovskite films deposited by solution onto thin plastic foils. The 3D–2D mixture allows to obtain micrometer‐thick and highly uniform films that constitute the detector's active layer. The devices demonstrate excellent flexibility with stable electric transport properties down to a bending radius of 3.1 mm. The detector is characterized under a 5 MeV proton beam with fluxes in the range [4.5 × 105 – 1.4 × 109] H+ cm−2 s−1, exhibiting a stable response to repetitive irradiation cycles with sensitivity up to (290 ± 40) nC Gy−1mm−3 and a limit of detection down to (72±2) µGy s−1. The detector radiation tolerance is also assessed up to a total of 1.7 × 1012 protons impinging on the beam spot area, with a maximum variation of the detector's response of 14%.
Organic semiconductors are a promising material candidate for X‐ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X‐ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high‐sensitivity performance for X‐ray detectors based on organic semiconductors modified with high –Z heteroatoms. X‐ray detectors are fabricated with p‐type organic semiconductors containing selenium heteroatoms (poly(3‐hexyl)selenophene (P3HSe)) in blends with an n‐type fullerene derivative ([6,6]‐Phenyl C71 butyric acid methyl ester (PC70BM). When characterized under 70, 100, 150, and 220 kVp X‐ray radiation, these heteroatom‐containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy−1 cm−2 with respect to the bismuth oxide (Bi2O3) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron‐hole pairs, better charge transfer, and charge transport characteristics in heteroatom‐incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X‐ray detectors that can be curved to a radius as low as 2 mm with low deviation in X‐ray response under 100 repeated bending cycles while maintaining an industry‐standard ultra‐low dark current of 0.03 ± 0.01 pA mm−2.