15 December 2024 in Journal of X-Ray Science and Technology
Due to the hardware constraints of Computed Tomography (CT) imaging, acquiring high-resolution (HR) CT images in clinical settings poses a significant challenge. In recent years, convolutional neural networks have shown great potential in CT super-resolution (SR) problems. However, the reconstruction results of many deep learning-based SR methods have structural distortion and detail ambiguity. In this paper, a new SR network based on generative adversarial learning is proposed. The network consists of gradient branch and SR branch. Gradient branch is used to recover HR gradient maps. The network merges gradient image features of the gradient branch into the SR branch, offering gradient information guidance for super-resolution (SR) reconstruction. Further, the loss function of the network combines the image space loss function with the gradient loss and the gradient variance loss to further generate a more realistic detail texture. Compared to other comparison algorithms, the structural similarity index of the SR results obtained by the proposed method on simulation and experimental data has increased by 1.8% and 1.4%, respectively. The experimental results demonstrate that the proposed CT SR network exhibits superior performance in terms of structure preservation and detail restoration.
9 September 2025 in TechRxiv
Sparse-view sampling for computed tomography (CT) reduces radiation exposure in medical imaging but suffers from severe artifacts due to ill-posed nature of under-sampled reconstruction. While diffusion posterior sampling (DPS) leverages data-driven priors for improved results, its stochastic nature impedes clinical reproducibility, and inefficient noise-perturbed likelihood estimation limits practicality. This work proposes the probabilistic ordinary differential equation (ODE)-driven Deterministic Diffusion Posterior Sampling (ODDPS) framework to enable stable, high-quality sparse-view CT reconstruction by combining physical constraints with deterministic generative sampling. ODDPS reformulates stochastic diffusion into a probability flow ODE, ensuring deterministic sampling from noise to image. In this work, a dual-domain solver is proposed, which integrates diffusion processes in the image domain and sinogram domain, and decouples the problem into a physicsbased likelihood term and a diffusion-based prior term under the Bayesian framework. Specifically, the prior term is solved using the recently proposed first-order solver of diffusion probabilistic model, while the likelihood term adopts an efficient physicsbased likelihood gradient to avoid neural backpropagation in each iteration. This design bridges tomographic physics and the learned diffusion prior within an unified framework, ensuring the consistency between the reconstruction results and the physical constraints of CT imaging. Evaluated on public datasets, ODDPS achieved average improvements of 1.19 dB and 5% in peak signalto-noise ratio and structural similarity index measured under the 30 views, and is 48.6% faster reconstruction than DPS. Ablation studies confirmed near-zero variance in outputs and significant artifact suppression. By unifying ODE-driven deterministic sampling with dual-domain diffusion, ODDPS delivers reproducible, high-fidelity sparse-view CT reconstructions. Its efficiency and Repeatability advance the clinical translation of diffusion models for inverse problems.
13 January 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Sparse-view sampling for computed tomography (CT) reduces radiation exposure in medical imaging but suffers from severe artifacts due to ill-posed nature of under-sampled reconstruction. While diffusion posterior sampling (DPS) leverages data-driven priors for improved results, its stochastic nature impedes clinical reproducibility, and inefficient noise-perturbed likelihood estimation limits practicality. This work proposes the probabilistic ordinary differential equation (ODE)-driven deterministic diffusion posterior sampling (ODDPS) framework to enable stable, high-quality sparse-view CT reconstruction by combining physical constraints with deterministic generative sampling. ODDPS reformulates stochastic diffusion into a probability flow ODE, ensuring deterministic sampling from noise to image. In this work, a dual-domain solver is proposed, which integrates diffusion processes in the image domain and sinogram domain, and decouples the problem into a physics-based likelihood term and a diffusion-based prior term under the Bayesian framework. Specifically, the prior term is solved using the recently proposed first-order solver of diffusion probabilistic model, while the likelihood term adopts an efficient physics-based likelihood gradient to avoid neural backpropagation in each iteration. This design bridges tomographic physics and the learned diffusion prior within a unified framework, ensuring the consistency between the reconstruction results and the physical constraints of CT imaging. Evaluated on public LIDC dataset, ODDPS achieved average improvements of 1.2 dB and 5.82% in peak signal-to-noise ratio and structural similarity index measured under the 30 views, and is 48.6% faster reconstruction than DPS. Ablation studies confirmed near-zero variance in outputs and significant artifact suppression. By unifying ODE-driven deterministic sampling with dual-domain diffusion, ODDPS delivers reproducible, high-fidelity sparse-view CT reconstructions. Its efficiency and repeatability advance the clinical translation of diffusion models for inverse problems.
12 March 2026 in Journal of X-Ray Science and Technology
Reducing radiation dose in computed tomography (CT) and photon-counting CT (PCCT) is crucial for patient safety, but lower doses introduce noise that degrades image quality. Existing denoising methods often rely on supervised learning of paired data or are based on specific noise assumptions, which poses challenges in clinical practice. A novel Visual-Language Model-assisted CT Denoising (VLD) framework is proposed to address CT image noise while preserving diagnostic fidelity through semantic guidance. Our method innovatively leverages the human-level knowledge embedded in multimodal visual-language models and applies it to the field of CT image denoising. This approach enables the diffusion model to perform restoration guided by semantic understanding. Meanwhile, a tri-domain consistency framework has been proposed to further enhance image quality by progressively refining details while preserving structural integrity. Extensive experiments on both simulated CT and real PCCT data demonstrate that the VLD method generates high-quality reconstruction images and exhibits robust generalization to new scenarios. In simulation experiments, the VLD method achieves average improvements of 0.95 dB and 1.21 dB in peak signal-to-noise ratio under the 5000-photon number condition, outperforming the WGAN and FBPConvNet methods, which require paired data.