Francesco Bertelli

Francesco Bertelli

Auto-generated profile, based on publicly available information

Francesco Bertelli

Pediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2021 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
FRFrancesca Raimondi
Francesca Raimondi
Vladimiro VidaVladimiro Vida
Vladimiro Vida
CGCharlotte Godard
Charlotte Godard
FBFrancesco Bertelli
Francesco Bertelli
ERElena Reffo
Elena Reffo
JMJean-Baptiste Masson
Jean-Baptiste Masson

1 June 2023 in Interdisciplinary CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
FBFrancesco Bertelli
Francesco Bertelli
FRFrancesca Raimondi
Francesca Raimondi
CGCharlotte Godard
Charlotte Godard
EBEmma Bergonzoni
Emma Bergonzoni
CCClaudia Cattapan
Claudia Cattapan
Vladimiro VidaVladimiro Vida
Vladimiro Vida
OBJECTIVES: Two limitations of the clinical use of 3-dimensional (3D) reconstruction and virtual reality systems are the relatively high cost and the amount of experience required to use hardware and software to effectively explore medical images. We have tried to simplify the process and validate a new tool developed for this purpose with a novel software package. METHODS: Five patients with right partial anomalous pulmonary venous return with adequate preoperative images acquired with magnetic resonance imaging were enrolled. Five volunteers with no previous experience in the field of 3D reconstruction were instructed to use the software after viewing a short video tutorial. Users were then asked to create a 3D model of each patient's heart using DIVA software. Their results were compared quantitatively and qualitatively with a benchmark reconstruction performed by an experienced user. RESULTS: All our participants recreated 3D models in a relatively short time, maintaining a good overall quality (average quality score ≥ 3 on a scale of 1–5). The overall trend of all the parameters analysed showed a statistical improvement between case 1 and case 5, as users became more and more experienced. CONCLUSIONS: DIVA is a simple software program that allows accurate 3D reconstruction in a relatively short time (“fast-track” virtual reality). In this study, we demonstrated the potential use of DIVA by inexperienced users, with a significant improvement in quality and time after a few cases were performed. Further studies are needed to confirm the potential application of this technology on a larger scale.

1 June 2021 in Revista Espanola de Cardiologia
Verified
Journal Article
Closed access
CCClaudia Cattapan
Claudia Cattapan
FBFrancesco Bertelli
Francesco Bertelli
AGAlvise Guariento
Alvise Guariento
MAMatteo Andolfatto
Matteo Andolfatto
PVPaola Veronese
Paola Veronese
Vladimiro VidaVladimiro Vida
Vladimiro Vida

19 October 2023 in ASAIO Journal
Verified
Journal Article
Open access
EIEnrico G. Italiano
Enrico G. Italiano
FBFrancesco Bertelli
Francesco Bertelli
ICIrene Cao
Irene Cao
RMRaffaella Motta
Raffaella Motta
Giovanni Di SalvoGiovanni Di Salvo
Giovanni Di Salvo
MPMassimo A. Padalino
Massimo A. Padalino
The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.01 m2 undergoing a safe and effective HeartMate3 implantation despite extremely small thoracic dimensions. Using computed tomography-derived three-dimensional (3D) reconstruction, it was possible to simulate several device positions finding the best HeartMate3 lodging. Simulation-guided pump placement was then obtained in the operating room. Normal HeartMate3 functioning was registered until heart transplant. Our experience shows that preoperative planning and virtual fitting simulation can be effective to assess safety of HeartMate3 implantation even in small children. The 3D reconstruction and simulation may help to increase the pool of children candidates for this device, even though a larger experience is needed to assess the risk profile of the HeartMate3 in such small patients.