Weiming Zhang

Weiming Zhang

Auto-generated profile, based on publicly available information

Weiming Zhang

Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2026 in Brain Research Bulletin
Verified
Journal Article
Open access
STShuPeng Tao
ShuPeng Tao
WZWeiming Zhang
Weiming Zhang
JGJiande Guo
Jiande Guo
XSXizi Song
Xizi Song
XAXingwei An
Xingwei An
Ultrasound technology has become a highly promising tool in the field of neuroscience, particularly in brain imaging and neuromodulation. These techniques not only allow for non-invasive visualization of brain structure and functional activity but also enable precise modulation of neural activity, offering new perspectives for the diagnosis and treatment of brain diseases. Animal experiments and clinical studies have confirmed its effectiveness in brain research and therapeutic interventions. However, concerns regarding its safety remain. This review aims to systematically evaluate the safety of ultrasound-based brain imaging and neuromodulation. We examine the mechanisms that may lead to adverse effects, highlight key acoustic parameters that could impact safety, and summarize the acoustic parameters used in existing studies, along with their associated safety reports. The results indicate that, for ultrasound imaging, structural and hemodynamic imaging are generally safe, but prolonged exposure (>10 min) should still be avoided. For high-energy or microbubble-enhanced imaging techniques, strict control of the mechanical index, exposure duration, and microbubble dosage is necessary to minimize cavitation-induced damage. Regarding ultrasound modulation, diagnostic safety standards no longer apply-the safety threshold is significantly higher, with irreversible damage only occurring under high-intensity ultrasound (e.g.,ISPPA=280 W/cm2 in rodent models) or when combined with microbubbles.Finally, we emphasize the need for further systematic safety studies and the development of more precise safety guidelines for different technical principles and application scenarios to ensure the safe use of ultrasound technology in neuroscience.

8 November 2024
Verified
Conference Paper
Open access
WZWeiming Zhang
Weiming Zhang
JGJiande Guo
Jiande Guo
XSXizi Song
Xizi Song
Brain imaging technologies can reveal the neural basis behind thoughts, emotions, and behaviors. Acousto-electric brain imaging is an emerging neuroimaging technique with high spatiotemporal resolution. This study designed and implemented multi-frequency steady-state visual evoked stimuli in rats to explore the classification performance of acousto-electric imaging. Canonical correlation analysis was used to classify the signals, and results were compared with traditional scalp electroencephalography (EEG) methods. The findings indicate that acousto-electric brain imaging is less affected by electrode placement (n.s.) compared to traditional EEG(*). However, the classification performance of ABI signals still lags behind traditional EEG when averaging trials and placing electrode optimally(****).