Christopher Schlenk

Christopher Schlenk

Auto-generated profile, based on publicly available information

Christopher Schlenk

Institute of Robotics and Mechatronics, DLR, Weling, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
CSChristopher Schlenk
Christopher Schlenk
KHKatharina Hagmann
Katharina Hagmann
FSFlorian Steidle
Florian Steidle
LMLaura Oliva Maza
Laura Oliva Maza
AKAlexander Kolb
Alexander Kolb
AAAlin Albu-Schäffer
Alin Albu-Schäffer
Purpose The robotic system CoFlex for kidney stone removal via flexible ureteroscopy (fURS) by a single surgeon (solo surgery, abbreviated SSU) is introduced. It combines a versatile robotic arm and a commercially available ureteroscope to enable gravity compensation and safety functions like virtual walls. The haptic feedback from the operation site is comparable to manual fURS, as the surgeon actuates all ureteroscope DoF manually. Methods The system hardware and software as well as the design of an exploratory user study on the simulator model with non-medical participants and urology surgeons are described. For each user study task both objective measurements (e.g., completion time) and subjective user ratings of workload (using the NASA-TLX) and usability (using the System Usability Scale SUS) were obtained. Results CoFlex enabled SSU in fURS. The implemented setup procedure resulted in an average added setup time of 341.7 ± 71.6 s, a NASA-TLX value of 25.2 ± 13.3 and a SUS value of 82.9 ± 14.4. The ratio of inspected kidney calyces remained similar for robotic (93.68 %) and manual endoscope guidance (94.74 %), but the NASA-TLX values were higher (58.1 ± 16.0 vs. 48.9 ± 20.1) and the SUS values lower (51.5 ± 19.9 vs. 63.6 ± 15.3) in the robotic scenario. SSU in the fURS procedure increased the overall operation time from 1173.5 ± 355.7 s to 2131.0 ± 338.0 s, but reduced the number of required surgeons from two to one. Conclusions The evaluation of CoFlex in a user study covering a complete fURS intervention confirmed the technical feasibility of the concept and its potential to reduce surgeon working time. Future development steps will enhance the system ergonomics, minimize the users’ physical load while interacting with the robot and exploit the logged data from the user study to optimize the current fURS workflow.

28 July 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
CSChristopher Schlenk
Christopher Schlenk
JKJulian Klodmann
Julian Klodmann
KHKatharina Hagmann
Katharina Hagmann
AKAlexander Kolb
Alexander Kolb
AHAnja Hellings-Kus
Anja Hellings-Kus
AAAlin Albu-Schaffer
Alin Albu-Schaffer
Urolithiasis is a common disease with increasing prevalence across all ages. A common treatment option for smaller kidney stones is flexible ureterorenoscopy (fURS), where a flexible ureteroscope (FU) is used for stone removal and to inspect the renal collecting system. The handling of the flexible ureteroscope and end effectors (EEs), however, is challenging and requires two surgeons. In this article, we introduce a modular robotic system for endoscope manipulation, which enables solo surgery (SSU) and is adaptable to various hand-held FUs. Both the developed hardware components and the proposed workflow and its representation in software are described. We then present and discuss the results of an initial user study. Finally, we describe subsequent developmental steps towards more extensive testing by clinical staff.

27 March 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CSChristopher Schlenk
Christopher Schlenk
AHAnja Hellings-Kuß
Anja Hellings-Kuß
KHKatharina Hagmann
Katharina Hagmann
NBNikola Budjakoski
Nikola Budjakoski
LMLaura Oliva Maza
Laura Oliva Maza
AAAlin Albu-Schäffer
Alin Albu-Schäffer
In flexible ureteroscopy (fURS) for kidney stones, the renal collecting system is inspected and stones are removed with a flexible ureteroscope (FU). One alternative to the fragmentation of stones and their removal with the help of graspers or extraction baskets is the dusting of stones with laser light. To support a single surgeon during a fURS procedure, in particular with the fine manipulation during dusting, we developed the CoFlex TOP system for the teleoperation of a handheld FU with three degrees of freedom. This paper describes the overall structure of the system, its kinematics and the hardware and software components. Subsequently, the system properties and its position repeatability are investigated and the system's feasibility for a tip positioning task in virtual reality is evaluated in a user study. Finally, we discuss the implications of the evaluation and sketch possible foci of a user study with urology surgeons.