14 February 2022 in Applied Materials Today
30 April 2021 in ACS Omega
Rapid and sensitive pathogenic bacterial identification and isolation from complicated clinical specimens are of great importance for the early diagnosis and prevention of osteomyelitis. Herein, we proposed a novel methicillin-resistant Staphylococcus aureus (MRSA) detection strategy through two specially designed streptavidin magnetic bead-based probes, including a capture probe and a report probe. In detail, the capture probe takes the responsibility to specially bind with the surface protein of MRSA and leads to the liberation of the promoter which could subsequently initiate report probe-based signal amplification. Afterward, the hybridization of the promoter probe with the report probe could then transform the protruding 3′ terminus of template DNA in the report probe into a blunt end. With the assistance of Exo III, the template could be digested to liberate the promoter to form a recycle and to liberate the biprobe to induce the following rolling circle amplification (RCA)-based signal amplification. Through the integration of the Exo III-assisted recycle and RCA-based signal amplification, the proposed method exhibited a favorable detection performance.
1 January 2012 in Analytical Letters
In this work, a highly-sensitive and cost-effective detection approach based on the integration of tyramide signal amplification with a silver enhancement method (SEM-TSA) has been developed successfully. To demonstrate the feasibility of this approach, human IgG as a model target protein was employed and its concentration was assayed based on colorimetric detection. The analytical parameters including the concentrations of detection antibody, streptavidin-horseradish peroxidase, biotinyl tyramide, and streptavidin-nanogold were systematically optimized. The quantitative analysis was performed and a dynamic range was obtained from 0.18 ng/mL to 39.1 ng/mL, while no detectable images could be observed when the silver enhancement method (SEM) without TSA was used. The detection limits were 0.18 ng/mL and 21 ng/mL for SEM-TSA and SEM, respectively. The results showed that sensitivity of the presented colorimetric assay significantly increased by two-orders of magnitude. In addition, this method has been successfully applied in analyzing normal human serum samples. The results suggested the colorimetric detection method based on TSA-SEM has promising potential applications in biomedical analysis and clinical diagnosis.