Yingwei Qin

Yingwei Qin

Auto-generated profile, based on publicly available information

Yingwei Qin

North University of China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2025 in Optics Express
Verified
Journal Article
Closed access
YQYingwei Qin
Yingwei Qin
YLYihong Li
Yihong Li
XSXueqin Sun
Xueqin Sun
YLYu Li
Yu Li
SWSukai Wang
Sukai Wang
PCPing Chen
Ping Chen
Micro-CT imaging is widely used in materials science, biomedical research, geological exploration, and industrial inspection due to its non-destructive capabilities. However, traditional systems face challenges due to limitations in spatial bandwidth product (SBP), making it difficult to achieve both a large field-of-view (FOV) and high-resolution imaging simultaneously. This paper presents a segmented light deflection method using cascaded optical fiber tapers integrated within a “fiber taper–image intensifier-camera” coupling architecture. This design reduces distortion caused by large taper ratios in single-stage systems. Additionally, a multi-view geometric registration calibration approach is developed based on CT projection geometric constraints to address mismatches between traditional 2D planar distortion correction methods and CT projection geometry. A cascaded fiber taper array (53 mm input - 34 mm intermediate - 16 mm output) was implemented in a 2 × 2 tiling configuration. The system achieves wide-FOV micro-CT imaging with a maximum imaging area of 106.4 × 106.4 mm2. Resolution testing confirmed a 3 μm resolution within a 4.1 × 4.1 mm2 FOV. System reconstruction efficacy was validated through rock core and printed circuit board (PCB) samples.

22 October 2025 in Optics Express
Verified
Journal Article
Closed access
YQYingwei Qin
Yingwei Qin
YLYihong Li
Yihong Li
XSXueqin Sun
Xueqin Sun
YLYu Li
Yu Li
SWSukai Wang
Sukai Wang
PCPing Chen
Ping Chen
Multi-view X-ray imaging systems extend the imaging field of view by integrating multiple imaging modules. Nevertheless, inter-module performance variations in detector arrays, gain drift, and angle-dependent effects cause cross-view grayscale inconsistencies, which degrade overall imaging quality. While existing X-ray imaging approaches primarily rely on single-view flat-field correction or per-projection normalization, these strategies remain inadequate for achieving global consistency across views. To overcome this limitation, this study proposes a physics-constrained multi-view image correction (PCMIC) method. By constructing a globally shared attenuation field to model view-specific nonlinear responses and incorporating boundary anchoring together with monotonicity constraints, the method ensures strong physical fidelity. Experiments conducted on a self-developed large-field, high-resolution micro-CT system demonstrate that PCMIC effectively suppresses stitching artifacts and improves grayscale consistency, structural fidelity, and quantitative stability.