Arsenic is naturally found in surface and ground waters and the inorganic forms of arsenic are the most toxic forms. The adverse health effects of arsenic may involve the respiratory, gastrointestinal, cardiovascular, nervous, and haematopoietic systems. Arsenic contamination in drinking water is a global problem widely seen in Bangladesh and West Bengal of the Indian sub continent. As there is a great demand for field test kits due to the anticipated reduction of the US EPA arsenic standard from 50ppb to 10ppb a field kit which offers rapid, simple and safe method for precise estimation of arsenic at 10ppb in drinking water samples is developed. Field methods, based on the mercuric-bromide-stain, consist of three different major parts, which are carried out stepwise. The first part of the procedure is to remove serious interference caused by hydrogen sulphide. In commercially available kits either the sulphide is oxidized to sulphate and the excess oxidizing reagent removed prior to the hydride generation step or, the hydrogen sulphide is filtered out by passing the gas stream through a filter impregnated with lead acetate during the hydride generation step. The present method employs cupric chloride in combination with ferric chloride or Fenton’s reagent for the removal of hydrogen sulphide, which is rapid, simple and more efficient. Other interferences at this step of the analyses are normally not expected for drinking water analysis. In the second step, the generation of the arsine gas involves the classical way of using zinc metal and hydrochloric acid, which produce the ‘nascent’ hydrogen, which is the actual reducing agent. Hydrochloric acid can be replaced by sulfamic acid, which is solid and avoids a major disadvantage of having to handle a corrosive liquid in the field. The arsine gas produces a yellowish spot on the reagent paper. Depending on the arsenic content, either, Yellow – H (HgBr) 2 As (10-50ppb), Brown – (HgBr) 3 As (50-100ppb) or Black – Hg3 As2 (>100ppb) are formed which can be precisely estimated by visual comparison with standard color chart. The results obtained by field kits agree well with the data obtained through I.C.P.AES methods. The most important characteristic for field measurement is that analytical results can be obtained on the site where the sample is taken with high precision and can be conveniently utilized for monitoring arsenic rapidly in a highly contaminated large geographical area.
Lectures and little emphasis is on student involvement. To enhance the skills of the students/learners they need to be involved in the learning process. This paper describes the use of Process Oriented Guided Inquiry Learning (POGIL) in an engineering and management college in Andhra Pradesh, India. Though POGIL has been developed and validated extensively over the last 15 years in the US, it is quite new in the Indian scenario and in Engineering and Management education. The authors share the process steps followed in introducing POGIL in the classroom and highlight the changes that they observed in the students and the teachers after introducing POGIL. The authors observed increased classroom interaction and improved grades in students. These positive findings encourage the authors to further use POGIL in engineering and management and spread POGIL to other colleges.
1 January 2017 in IOSR Journal of Environmental Science, Toxicology and Food Technology
This study presents a novel numerical approach for analysis on thermo-viscous steady fluid motion over the moving rectangular permeable objects . The numerical results have been found employing Runge-Kutta method of order 6 shooting techniques developed in Mathematica software Numerical differentiation(ND) solve for the flow adaptable equations comprising temperature and velocity. The flow behavior and the impacts of material constraints on the flow region for governed equations of airflow around the aircrafts wings have been analyzed and deliberated taking the help from the generated graphs. The nonlinear coupled Partial differential equations(PDE’s) in terms of temperature and velocity, subject to the corresponding boundary conditions, control the fluid motion. The numerical computations of Runge-Kutta(R-K) 6th order results are presented in form of tables and also represented for numerous thermo physical coefficient values. The variations of these flow fields have been studied for wide spectrum of physical characteristics which influences the nature of thermo-viscous fluid. The impact of suction/injection parameter, dimensionless viscosity factor, constant pressure and temperature gradients, thermo physical factors and the Prandtl parameter effect on flow region have explored using graphical illustrations with the wide range of values. The Explicit numerical calculations also been calculated and results are associated through the current outcomes in the literature. To improve heat transfer rates in systems such as heat exchangers and aerospace components, engineers can optimize surface textures and flow conditions by taking coefficients effects on flow considerations into account.
1 January 2009 in The International Journal of Environmental, Cultural, Economic, and Social Sustainability: Annual Review