David Bensason

David Bensason

Auto-generated profile, based on publicly available information

David Bensason

Flow Physics and Technology, Faculty of Aerospace Engineering, Delft University of Technology, Delft, The Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Open access
PDF file
DBD. Bensason
D. Bensason
ESEric Simley
Eric Simley
ORO. Roberts
O. Roberts
PFPaul Fleming
Paul Fleming
MDM. Debnath
M. Debnath
RMR. Mudafort
R. Mudafort
The wind power plant-wide control strategy known as wake steering involves the misalignment of upstream turbines with the wind direction to deflect wakes away from downstream turbines, increasing net wind plant power production. In this paper, we evaluate the potential of wake steering for U.S. land-based wind power plants. First, we outline a method for simulating and optimizing wake steering control for existing wind plants by combining the flow redirection and induction in steady state wake steering engineering model with the U.S. Wind Turbine Database and Wind Integration National Dataset Toolkit wind resource dataset. Next, to better understand the potential benefits of wake steering beyond those for existing wind plants, we evaluate the relative impacts of turbine specific power, turbine spacing, and mean wind speed on energy gain and levelized cost of energy (LCOE) using a model land-based wind power plant. For a subset of 60 existing wind plants, assuming a constant turbulence intensity of 8%, wake steering was found to yield an average annual energy production (AEP) gain of 0.80%, equivalent to recovering 13.85% of baseline wake losses. Further, we present a linear approximation between baseline wake losses and AEP gains that can be used to estimate wake steering gains for other wind power plants. Highlighting additional benefits of wake steering, for the model wind power plant we found that energy gains from wake steering enabled an approximate 30% reduction in turbine spacing while keeping LCOE constant.

8 August 2024 in Wind Energy
Verified
Journal Article
Open access
DBDavid Bensason
David Bensason
ASAndrea Sciacchitano
Andrea Sciacchitano
AAAdhyanth Giri Ajay
Adhyanth Giri Ajay
CFCarlos Simao Ferreira
Carlos Simao Ferreira
Recent studies have revealed the large potential of vertical‐axis wind turbines (VAWTs) for high‐energy‐density wind farms due to their favorable wake recovery characteristics. The present study provides an experimental demonstration and proof‐of‐concept for the wake recovery mechanism of the novel X‐Rotor VAWT. The phase‐locked flowfield is measured at several streamwise locations along the X‐Rotor's wake using stereoscopic particle image velocimetry (PIV) with fixed‐pitch offsets applied to the blades. The streamwise vortex system of the upper half of the X‐Rotor is first hypothesized and then experimentally verified. The induced wake deformations of the vortex systems are discussed in comparison with previous studies concerning traditional H‐type VAWTs. The results suggest that positive blade pitch is more favorable for accelerated wake recovery due to the dominant tip‐vortex generated on the upwind windward quadrant of the cycle. Utilizing theoretical blade load variations along the span explains distinct unsteady flow features in the near wake generated at select quadrants of the rotor rotation, shedding light on the potential of the two pitch schemes.

30 July 2025 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
DBDavid Bensason
David Bensason
JMJayant Mulay
Jayant Mulay
ASAndrea Sciacchitano
Andrea Sciacchitano
CFCarlos Ferreira
Carlos Ferreira
The present study extends the idea of the vertical-axis wind turbine (VAWT) “vortex generator mode” for wake recovery on a wind farm scale, working towards the concept of “regenerative wind farming”, where upstream turbines entrain vertical momentum for those downstream. An experimental wind tunnel demonstration of the regenerative wind farming concept for an array of nine H-type VAWTs arranged in a 3×3 grid layout is performed. Volumetric particle tracking velocimetry measures the wake within the simulated wind farm while using two vortex generator modes achieved through a fixed blade pitch. The results demonstrate the strong dependence of the wake topology of a VAWT on the streamwise vorticity system, which can be effectively modified by pitching the blades and subsequently changing the load distribution of the different quadrants of a VAWT. An increase in momentum entrainment in the wake is observed for both vortex generator modes of operation, highlighting the potential of achieving regenerative wind farming. The derived available power within the farm increases by factors of 6.4 and 2.1 for the pitch-in and pitch-out cases compared to the baseline case, respectively, considering potential rotors directly in line with those upwind.

7 October 2025 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
DBDavid Bensason
David Bensason
ASAndrea Sciacchitano
Andrea Sciacchitano
CFCarlos Ferreira
Carlos Ferreira
Wake losses are a significant source of inefficiency in wind farm arrays, hindering the development of high-energy-density wind farms offshore. Studies have demonstrated the potential of vertical-axis wind turbines (VAWTs) to achieve high-energy-density configurations, due to their increased rate of wake recovery compared with their horizontal-axis counterparts. Recent works have demonstrated a wake control technique for VAWTs that utilizes blade pitch to accelerate the wake recovery, hereinafter referred to as the “vortex-generator” method. The present work is an experimental investigation of the wake topology using this control technique for the novel X-Rotor VAWT. The time-averaged wake topology of the X-Rotor has been measured by stereoscopic particle-image velocimetry at three fixed-pitch conditions of the top blades, namely pitch-in, pitch-out, and a baseline case with no pitch applied. The results demonstrate the wake recovery mechanism linked to the streamwise vorticity system of the rotor and the mechanisms that lead to a streamwise momentum recovery, where the pitched-in case injects high-momentum flow from above the rotor while ejecting the wake from the sides. In contrast, the pitched-out case operates in a mirrored fashion, with high-momentum flow injected into the wake from the sides while low-momentum flow is ejected out axially above the rotor. These modes of operation demonstrate a significant increase in the available power for hypothetical downstream turbines, reaching as high as a factor of 2.2 two rotor diameters downstream compared with the baseline case. The pitched-in case exhibits a higher rate of momentum recovery in the wake, compared with the pitch-out configuration.

8 September 2025 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
AAAdhyanth Giri Ajay
Adhyanth Giri Ajay
DBDavid Bensason
David Bensason
DTDelphine De Tavernier
Delphine De Tavernier
Vertical-axis wind turbines (VAWTs) are gaining research attention in offshore energy due to their ability to operate in omnidirectional wind, the simpler design characteristics, and the potential for faster wake recovery. As part of this interest, a novel X-shaped VAWT (X-Rotor) has been proposed to minimise the levelised cost of energy by minimising capital and operational expenditures. While existing studies on the X-Rotor rely on numerical tools to analyse rotor performance, experimental validation remains limited, making it essential to assess the accuracy of these models in predicting the flowfield around the rotor. This study compares a free-wake vortex model (CACTUS) to stereoscopic particle image velocimetry (PIV) results for a scaled X-Rotor. Both qualitative and quantitative comparisons are performed, examining flowfield features with and without blade pitch offsets. Additionally, the study provides insights into the 3D aerodynamics introduced into the wake by the turbine’s coned blades. Results indicate that CACTUS is able to predict the flowfield to a reasonable extent within the rotor volume and in the very near wake when no pitch offsets are applied, with discrepancies attributed to the uncertainty of the polars at the low Reynolds numbers. However, with pitch offsets, significant deviations from experimental data are observed, suggesting the need for careful model tuning for full-scale X-Rotor analysis. Furthermore, the introduction of coned blades enhances the 3D effects, generating notable upwash and downwash in the wake. These findings highlight the importance of using 3D aerodynamic tools over 2D approaches in future X-Rotor analyses to accurately capture vertical flow components.

28 January 2025 in EGUsphere
Verified
Preprint
Open access
PDF file
DBDavid Bensason
David Bensason
ASAndrea Sciacchitano
Andrea Sciacchitano
CFCarlos Ferreira
Carlos Ferreira
Wake losses are a significant source of inefficiencies in wind farm arrays, hindering the development of high-energy density wind farms offshore. Studies have demonstrated the potential of vertical-axis wind turbines (VAWTs) to achieve high-energy density configurations due to their increased rate of wake recovery compared to their horizontal-axis counterparts. Recent works have demonstrated a wake control technique for VAWTs that utilizes blade pitch to accelerate the wake recovery, hereinafter referred to as the "vortex-generator" method. The present work is an experimental investigation of the wake topology using this control technique for the novel X-Rotor VAWT. The time-averaged wake topology of the X-rotor has been measured by stereoscopic particle-image velocimetry at three fixed-pitch conditions of the top blades, namely a pitch-in, pitch-out, and a baseline case with no pitch applied. The results demonstrate the wake recovery mechanism linked to the streamwise vorticity system of the rotor and the mechanisms that lead to a streamwise momentum recovery, where the pitched-in case injects high momentum flow from above the rotor while ejecting the wake from the sides. In contrast, the pitched-out case operates in a mirrored fashion, with high momentum flow injected into the wake from the sides while low-momentum flow is ejected out axially above the rotor. These modes of operation demonstrate a significant increase in the available power for hypothetical downstream turbines, reaching as high as a factor of 2.2 two rotor diameters downstream compared to the baseline case. The pitched-in case exhibits a higher rate of momentum recovery in the wake compared to the pitch-out configuration.