Zakia Anjum

Zakia Anjum

Auto-generated profile, based on publicly available information

Zakia Anjum

Department of Physics, Plasma Physics Laboratory, COMSATS University, Islamabad, Pakistan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
MFMuhammad Farooq
Muhammad Farooq
UIUsama Ijaz
Usama Ijaz
ZAZakia Anjum
Zakia Anjum
NRNajeeb Rehman
Najeeb Rehman
Underwater discharge plasmas are widely acclaimed for their potential applications in wastewater treatment, biomedical sciences, and industry. This article reports on pre- and post-breakdown characteristics of nanosecond pulsed plasma discharge generated in oxygen–water mixture flowing through a quartz capillary tube. In pre-breakdown region of applied voltage range of 4–4.5 kV, medium capacitance varies between 20 and 26 pF. For applied voltage range of 5–9 kV, a plasma discharge was observed during which the prominent current and voltage peaks show 5–10-ns phase difference. Electron number density was estimated using current density and Stark broadening techniques. It was noted that electron number density estimated from current density values ranges from 0.08 $\times \,\,10^{\mathrm {23 {}}}\,\,\text{m}^{-3}$ to 0.18 $\times \,\,10^{23}\,\,\text{m}^{-3}$ , while the electron number density estimated from Stark broadening of Balmer series hydrogen $H_{\alpha }$ and $H_{\beta }{}$ lines was found between 1.26 $\times \,\,10^{23}\,\,\text{m}^{-3}$ –2.69 $\times \,\,10^{23}\,\,\text{m}^{-3}$ and 1.25 $\times \,\,10^{23}\,\,\text{m}^{-3}$ –2.52 $\times \,\,10^{23}\,\,\text{m}^{-3}$ , respectively. The estimated values of plasma coupling parameter were in the range of 0.031–0.21, indicating the generated plasma to be on the margins of noncoupling ideal plasma to nonideal weakly coupled plasma. Effect of oxygen–water mixture flow direction on discharge stability and other plasma parameters was also monitored. It was observed that plasma discharge was more stable with higher electron number density in the direction of fluid flow.

1 November 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZAZakia Anjum
Zakia Anjum
NRNajeeb Rehman
Najeeb Rehman
The time-resolved measurements of the plasma parameters are carried out in a pulse-modulated low pressure capacitively coupled discharge operated in argon and argon–oxygen mixtures. Measurements are performed at a constant radio-frequency (RF) power of 130 W at 13.56 MHz, with the pulse repetition frequency of 1 kHz and 50% duty cycle. A single RF compensated Langmuir probe, synchronized with the modulated signal, is used to investigate the effects of filling gas pressure and O2 content in the discharge on the temporal evolution of electron density ne, electron temperature Te, plasma potential Vp, and electron energy probability function (EEPF). ne shows a rapid increase with time during the start of the pulse-on phase, followed by a gradual increase to attain a steady state value. During the pulse-off phase, ne decreases gradually. ne drops at a higher pressure and with increasing O2 content in the discharge. The temporal variations in Te and Vp, on the other hand, are more abrupt than the temporal variation in ne during the rise and the fall of the pulse. Both Te and Vp show an increase with rising pressure and with increasing O2 content in the discharge. The investigation of the temporal evolution of the EEPF reveals that the discharge is in a highly non-equilibrium state at the start of the pulse and evolves from bi-Maxwellian to Maxwellian distribution with the passage of time. The density of low energy electrons decreases, while the density of high energy electrons increases with increasing pressure and O2 content in the discharge. Moreover, several peaks and broadening in the EEPF profile are also noted with increasing O2 content.