In this paper, the hybrid electromagnetic model is applied to calculate lightning-induced voltages over a lossy ground. Results provided by this model are compared with experimental data obtained from a reduced-scale model and with results simulated by the numerical electromagnetics code. Good agreement is achieved in all cases.
4 February 2014 in IEEE Transactions on Electromagnetic Compatibility
This paper presents the calculation of electric and magnetic fields produced by lightning striking over different configurations of nonflat lossy ground. The computation is performed using finite-difference time domain (FDTD) methods in two-dimensional (2-D) with cylindrical coordinate systems and 3-D with Cartesian coordinates. The FDTD method is validated with several previous approximations for lightning electric field computation, such as Uman equations and simulation of lightning striking on the top of a tower. In this study, it is found that lightning striking on the top of a cone-shaped mountain may produce several variations on an electromagnetic field. An enhancement of the perpendicular and parallel to ground electric field components was observed for a cone-shaped configuration only. For configurations that include flat planes, wave reflections due to the transition between the cone-shaped and flat plane were observed.
This paper presents a recent characterization review of three cloud-to-ground lightning parameters [lightning peak current, ground flash density, and keraunic level (KL)] used in engineering applications based on available data from studies conducted in some tropical countries of Central and South America (Brazil, Colombia, Costa Rica, and Venezuela), considering seasonal and spatial variation aspects. There are some differences between the behaviors of the analyzed parameters in tropical areas in comparison with those published in the literature for temperate ones. The most significant conclusion is that historical data suggest that the highest ground flash density are located between latitude of 8° and 10° north. This value is much higher than the highest values reported for countries located in temperate regions. It is seen from the KL analysis that this parameter varies depending on the latitude with values up to 200 thunderstorm days (TDs).
This paper presents a methodology for thunderstorm warning alarming using electric field measurements and lightning location data under mountainous conditions in Medellín - Colombia. The methodology is used to set warning criteria for preventing human and sensitive systems risks and damages.