Damian Kukla

Damian Kukla

Auto-generated profile, based on publicly available information

Damian Kukla

Inżynieria Rzeszów Inżynieria Rzeszów S.A.

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
KAKozłowski Aleksander
Kozłowski Aleksander
KDKukla Damian
Kukla Damian
Experimental tests of steel unstiffened double side bolted end-plate joints have been presented. The main aim of the conducted tests was to check the behavior of joints in an accidental situation and possibility of creating secondary mechanism, i.e. catenary action in the scenario of column loss. Two types of end plate joints were tested: flush end-plate (FP) and extended end-plate (EP) with different thickness and different number of bolt rows in each. The tests were carried out on an isolated cross beam-column-beam type system until joint failure. During tests the available moment resistance and rotation capacity of bending joints and also values of tension forces in the beam were determined. The joints with extended end-plate have demonstrated higher bending and rotational capacity than flush end-plate. Significant deformation of column flanges, web and end plate were observed. The fracture of bolts was the failure mode of joints. Obtained results of axial force values in beam exceeded standard requirement what confirmed that the joints with unstiffened web column, flush or extended end-plate possess the ability of development the catenary action.

21 July 2023 in International Journal of Steel Structures
Verified
Journal Article
Open access
PDF file
DKDamian Kukla
Damian Kukla
AKAleksander Kozlowski
Aleksander Kozlowski
The research project was carried out to estimate the robustness of flat steel-framed structures in a selected accidental situation. For this purpose, a multistage approach based on experimental tests and numerical analysis was performed. As the main objective of the work, a numerical dynamic analysis of the steel frames was performed under a sudden and gradual internal column loss scenario. FEA models were created in Abaqus software using solid and shell elements. Computer analyzes were carried out in a number of different cases, taking into account the size of the structure, the type of joints, and the method of removing the column from the structure. Detailed results on the axial forces and rotation of the joints under analysis are presented, and the robustness of the structures is estimated. In all cases of frames with flush end-plate joints, an insufficient level of robustness was observed and failures of the structures were obtained. In the cases of application of extended end-plate joints in frame analysis, the required level of robustness was reached in all cases and the stop of collapse was obtained. Finally, practical recommendations for designing robust joints and the whole frame structure are presented.


30 December 2022 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
DKDamian Kukla
Damian Kukla
AKAleksander Kozlowski
Aleksander Kozlowski
The current design codes recommend designing the building structures based on the assumption avoiding the disproportionate to the initial cause damage during accidental situation. As a main strategy to mitigate a progressive collapse an alternative load path method is recommended. Flush and extended bolted end-plate joint to connect beam-to-column were experimentally tested. Hierarchical validation of joint FEM models based on experimental test results were performed. The numerical dynamic analysis by finite element method of selected steel frame under column loss scenario is presented. The planar 2D model of frame were used. Shell elements for beams and columns and solid elements for joints were employed respectively. Nonlinear material and geometry were applied in the analysis. Johnson-Cook model was used to describe the change of steel parameters by dynamic Increase Factor (DIF). The Rayleigh model to include the damping effects in the analysis was used. The dynamic analysis was performed with the use of Abaqus/Explicit module. Main conclusion of presented research it that to achieve the required level of robustness, bolted beam-to-column joints with extended end-plate of thickness more than 15 mm should be used.

4 February 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
DKDamian Kukla
Damian Kukla
AKAleksander Kozłowski
Aleksander Kozłowski
BMBartosz Miller
Bartosz Miller
DZDominika Ziaja
Dominika Ziaja
IWIzabela Wójcik-Grząba
Izabela Wójcik-Grząba
SGSylwia Gubernat
Sylwia Gubernat

21 March 2025 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
DKDamian Kukla
Damian Kukla
AKAleksander Kozlowski
Aleksander Kozlowski
The continuation of a multistage research project based on experimental and numerical analysis is presented, focused on the robustness of the steel frame structure with bolted end-plate joints. An advanced FE model, validated on previously performed experimental tests of steel bolted joints and steel subframe structure, was used. A dynamic numerical analysis of planar steel structures was performed under a sudden internal column loss scenario using Abaqus software. An attempt was made to increase structural robustness in the event of a sudden removal of the internal column at the ground level of the steel frame with flush bolted end-plate joints. The application of a strategy based on the change of types of joints at the selected level of the structure was shown. Two main structural changes were implemented by using bolted extended end-plate joints, instead of flush end-plate, or by using the novel joint with additional rings. To check the behaviour of the structure and assess its robustness, a change of the joints was applied at the lower and upper levels of the structure. The use of bolted extended end-plate joints only in one level of the structure leads to progressive collapse of part of the structure. The application of the novel joint with additional double rings at one level of the frame in both analyses leads to obtain a required level of robustness and mitigates collapse of the structure.