Yutao Liu

Yutao Liu

Auto-generated profile, based on publicly available information

Yutao Liu

State Grid Tieling Electric Power Supply Company,Tieling,China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2021 in IEEE Access
Verified
Journal Article
Open access
HSHuer Sun
Huer Sun
FLFuwang Liang
Fuwang Liang
YLYutao Liu
Yutao Liu
KLKexin Liu
Kexin Liu
WZWang Zhijian
Wang Zhijian
YZYang Zhao
Yang Zhao
Recently, cyclostationary blind deconvolution (CYCBD) is often used in gearbox fault feature extraction, and it is more effective in recovering single periodic pulse. However, in the engineering application of CYCBD, the filter length ( $L$ ) and cycle frequency ( $\alpha$ ) need to be verified and set through a large number of experiments, and the efficiency is very low; Moreover, the effect is not good when it is used to extract composite fault features under the background of strong noise. In order to overcome the above limitations, empirical mode decomposition (EEMD) is used to preprocess the composite fault. EEMD can remove the high-frequency noise and weak correlation components in the sampled signal. The strong correlation component is reconstructed to obtain the modal function closer to the fault frequency. The chimpanzee intelligent algorithm is applied to the determination of $L$ and $\alpha $ of CYCBD by optimization to form an adaptive CYCBD. Adaptive CYCBD takes the dispersion entropy of envelope spectrum as the fitness function of chimpanzee optimization algorithm (CHOA), and finds the optimal $L$ and $\alpha $ through iteration. The optimal parameter value is applied to CYCBD, and the reconstructed modal function is deconvoluted to obtain the optimal inverse filter, so as to accurately separate the fault characteristic components. Simulation and experimental results show that this method is effective for gearbox composite fault diagnosis and extraction under strong noise background.

27 October 2023
Verified
Conference Paper
Closed access
YLYutao Liu
Yutao Liu
LRLu Ren
Lu Ren
TGTongcheng Gao
Tongcheng Gao
MTMing Tian
Ming Tian
HXHaotian Xia
Haotian Xia
YHYilu Han
Yilu Han
220kV transmission line wind bias tripping fault is a common fault type in transmission lines, which has a great impact on the stability and safety of the system, especially in some harsh environmental conditions where 220kV transmission line wind bias faults occur at a higher rate. In this paper, we analyze a wind bias fault caused by sudden windy weather in the transmission line of Tieling Power Supply Company of State Grid Liaoning Province, find out the causes of the fault and propose wind bias prevention and transformation measures to effectively reduce the impact of wind bias fault on the stability of transmission line and improve the safety and stability of the line.