Ivanka Stajner

Ivanka Stajner

Auto-generated profile, based on publicly available information

Ivanka Stajner

Environmental Modeling Center, NOAA/NWS/NCEP, College Park, MD, USA

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Atmospheric Environment
Verified
Journal Article
Open access
QTQuansong Tong
Quansong Tong
LLLok Lamsal
Lok Lamsal
LPLi Pan
Li Pan
CDCharles Ding
Charles Ding
HKHyuncheol Kim
Hyuncheol Kim
ISIvanka Stajner
Ivanka Stajner

29 May 2008 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
ISIvanka Stajner
Ivanka Stajner
KWKrzysztof Wargan
Krzysztof Wargan
SPSteven Pawson
Steven Pawson
HHHiroo Hayashi
Hiroo Hayashi
LCLang‐Ping Chang
Lang‐Ping Chang
JWJacquelyn C. Witte
Jacquelyn C. Witte
Retrievals from the Microwave Limb Sounder (MLS) and the Ozone Monitoring Instrument (OMI) on EOS‐Aura were included in the Goddard Earth Observing System version 4 (GEOS‐4) ozone data assimilation system. The distribution and daily to seasonal evolution of ozone in the stratosphere and troposphere during 2005 are investigated. In the lower stratosphere, where dynamical processes dominate, comparisons with independent ozonesonde and Measurement of Ozone and Water Vapour by Airbus In‐Service Aircraft (MOZAIC) data indicate mean agreement within 10%. In the troposphere, OMI and MLS provide constraints on the ozone column, but the ozone profile shape results from the parameterized ozone chemistry and the resolved and parameterized transport. Assimilation of OMI and MLS data improves tropospheric column estimates in the Atlantic region but leads to an overestimation in the tropical Pacific and an underestimation in the northern high and middle latitudes in winter and spring. Transport and data biases are considered in order to understand these discrepancies. Comparisons of assimilated tropospheric ozone columns with ozonesonde data reveal root‐mean‐square (RMS) differences of 2.9–7.2 Dobson units (DU), which are smaller than the model‐sonde RMS differences of 3.2–8.7 DU. Four different definitions of the tropopause using temperature lapse rate, potential vorticity (PV), and isentropic surfaces or ozone isosurfaces are compared with respect to their global impact on the estimated tropospheric ozone column. The largest sensitivity in the tropospheric ozone column is found near the subtropical jet, where the ozone‐ or PV‐determined tropopause typically lies below the lapse rate tropopause.

10 September 2008 in Environmental Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
YTYouhua Tang
Youhua Tang
PLPius Lee
Pius Lee
MTMarina Tsidulko
Marina Tsidulko
HHHo-Chun Huang
Ho-Chun Huang
JMJeffery T. McQueen
Jeffery T. McQueen
ISIvanka Stajner
Ivanka Stajner

16 November 2011 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
OCO. R. Cooper
O. R. Cooper
SOS. J. Oltmans
S. J. Oltmans
BJB. J. Johnson
B. J. Johnson
JBJ. Brioude
J. Brioude
WAW. Angevine
W. Angevine
ISI. Stajner
I. Stajner
[1] Since 1997, baseline ozone monitoring from the surface to the tropopause along the U.S. west coast has been limited to the weekly ozonesondes from Trinidad Head, California. To explore baseline ozone at other latitudes, an ozonesonde network was implemented during spring 2010, including four launch sites along the California coast. Modeling indicated that North American pollution plumes impacted the California coast primarily below 3 km, but had no measurable impact on the average coastal ozone profiles. Vertical and latitudinal variation in free tropospheric baseline ozone appears to be partly explained by polluted and stratospheric air masses that descend isentropically along the west coast. Above 3 km, the dominant sources of ozone precursors were China and international shipping, while international shipping was the greatest source below 2 km. Approximately 8–10% of the baseline ozone that enters California in the 0–6 km range impacts the surface of the USA, but very little reaches the eastern USA. Within California, the major impact of baseline ozone above 2 km is on the high elevation terrain of eastern California. Baseline ozone below 2 km has its strongest impact on the low elevation sites throughout the state. To quantify ozone production within California we compared inland ozone measurements to baseline measurements. For average daytime conditions, we found no enhancements of lower tropospheric ozone in the northern Central Valley, but enhancements of 12–23% were found in the southern Central Valley. Enhancements above Joshua Tree were greater, 33–41%, while the greatest enhancements occurred over the LA Basin, 32–63%.

29 October 2013 in Geoscientific Model Development
Verified
Journal Article
Open access
PDF file
TCT. Chai
T. Chai
HKHyun Kim
Hyun Kim
PLP. Lee
P. Lee
QTQuansong Tong
Quansong Tong
LPL. Pan
L. Pan
ISI. Stajner
I. Stajner
The National Air Quality Forecast Capability (NAQFC) project provides the US with operational and experimental real-time ozone predictions using two different versions of the three-dimensional Community Multi-scale Air Quality (CMAQ) modeling system. Routine evaluation using near-real-time AIRNow ozone measurements through 2011 showed better performance of the operational ozone predictions. In this work, quality-controlled and -assured Air Quality System (AQS) ozone and nitrogen dioxide (NO2) observations are used to evaluate the experimental predictions in 2010. It is found that both ozone and NO2 are overestimated over the contiguous US (CONUS), with annual biases of +5.6 and +5.1 ppbv, respectively. The annual root mean square errors (RMSEs) are 15.4 ppbv for ozone and 13.4 ppbv for NO2. For both species the overpredictions are most pronounced in the summer. The locations of the AQS monitoring sites are also utilized to stratify comparisons by the degree of urbanization. Comparisons for six predefined US regions show the highest annual biases for ozone predictions in Southeast (+10.5 ppbv) and for NO2 in the Lower Middle (+8.1 ppbv) and Pacific Coast (+7.1 ppbv) regions. The spatial distributions of the NO2 biases in August show distinctively high values in the Los Angeles, Houston, and New Orleans areas. In addition to the standard statistics metrics, daily maximum eight-hour ozone categorical statistics are calculated using the current US ambient air quality standard (75 ppbv) and another lower threshold (70 ppbv). Using the 75 ppbv standard, the hit rate and proportion of correct over CONUS for the entire year are 0.64 and 0.96, respectively. Summertime biases show distinctive weekly patterns for ozone and NO2. Diurnal comparisons show that ozone overestimation is most severe in the morning, from 07:00 to 10:00 local time. For NO2, the morning predictions agree with the AQS observations reasonably well, but nighttime concentrations are overpredicted by around 100%.

10 July 2009 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Closed access
PDF file
JWJohn Worden
John Worden
DJDylan B. A. Jones
Dylan B. A. Jones
Jane LiuJane Liu
Jane Liu
MPMark Parrington
Mark Parrington
KBKevin Bowman
Kevin Bowman
HWHelen Worden
Helen Worden