Thomas Puiseux

Thomas Puiseux

Auto-generated profile, based on publicly available information

Thomas Puiseux

Spin Up ALARA Group Strasbourg France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
TPThomas Puiseux
Thomas Puiseux
ASAnou Sewonu
Anou Sewonu
OMOlivier Meyrignac
Olivier Meyrignac
HRHervé Rousseau
Hervé Rousseau
FNFranck Nicoud
Franck Nicoud
RMRamiro Moreno
Ramiro Moreno

26 March 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TPThomas Puiseux
Thomas Puiseux
ASAnou Sewonu
Anou Sewonu
RMRamiro Moreno
Ramiro Moreno
SMSimon Mendez
Simon Mendez
FNFranck Nicoud
Franck Nicoud
A numerical approach is presented to efficiently simulate time-resolved 3D phase-contrast Magnetic resonance Imaging (or 4D Flow MRI) acquisitions under realistic flow conditions. The Navier-Stokes and Bloch equations are simultaneously solved with an Eulerian-Lagrangian formalism. A semi-analytic solution for the Bloch equations as well as a periodic particle seeding strategy are developed to reduce the computational cost. The velocity reconstruction pipeline is first validated by considering a Poiseuille flow configuration. The 4D Flow MRI simulation procedure is then applied to the flow within an in vitro flow phantom typical of the cardiovascular system. The simulated MR velocity images compare favorably to both the flow computed by solving the Navier-Stokes equations and experimental 4D Flow MRI measurements. A practical application is finally presented in which the MRI simulation framework is used to identify the origins of the MRI measurement errors.

25 August 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MGMorgane Garreau
Morgane Garreau
TPThomas Puiseux
Thomas Puiseux
STSolenn Toupin
Solenn Toupin
DGDaniel Giese
Daniel Giese
SMSimon Mendez
Simon Mendez
RMRamiro Moreno
Ramiro Moreno
Purpose: To evaluate hemodynamic markers obtained by accelerated GRAPPA (R = 2, 3, 4) and compressed sensing (R = 7.6) 4D flow MRI sequences under complex flow conditions.Methods: The accelerated 4D flow MRI scans were performed on a pulsatile flow phantom, along with a nonaccelerated fully sampled k‐space acquisition. Computational fluid dynamics simulations based on the experimentally measured flow fields were conducted for additional comparison. Voxel‐wise comparisons (Bland–Altman analysis, ‐norm metric), as well as nonderived quantities (velocity profiles, flow rates, and peak velocities), were used to compare the velocity fields obtained from the different modalities.Results: 4D flow acquisitions and computational fluid dynamics depicted similar hemodynamic patterns. Voxel‐wise comparisons between the MRI scans highlighted larger discrepancies at the voxels located near the phantom's boundary walls. A trend for all MR scans to overestimate velocity profiles and peak velocities as compared to computational fluid dynamics was noticed in regions associated with high velocity or acceleration. However, good agreement for the flow rates was observed, and eddy‐current correction appeared essential for consistency of the flow rates measurements with respect to the principle of mass conservation.Conclusion: GRAPPA (R = 2, 3) and highly accelerated compressed sensing showed good agreement with the fully sampled acquisition. Yet, all 4D flow MRI scans were hampered by artifacts inherent to the phase‐contrast acquisition procedure. Computational fluid dynamics simulations are an interesting tool to assess these differences but are sensitive to modeling parameters.

22 February 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MGMorgane Garreau
Morgane Garreau
TPThomas Puiseux
Thomas Puiseux
RMRamiro Moreno
Ramiro Moreno
STSolenn Toupin
Solenn Toupin
DGDaniel Giese
Daniel Giese
SMSimon Mendez
Simon Mendez
Purpose: The aim of this study is to investigate the impact of the partial echo on 4D flow MRI sequences thanks to in silico coupled MRI‐CFD (computational fluid dynamics) simulations. Methods: Two sequences are studied: one with a full echo (FE) and another using partial echo (PE) with an echo symmetry fraction of 0.75. MRI‐CFD simulations are conducted on an in silico pulsatile flow phantom for a sinusoidal inflow and a physiological inflow typical of the ascending aorta. Results: For both inflow signals, PE‐based simulations exhibited better compliance with their matching CFD simulations compared to the FE ones. Conclusion: The reduction of flow misregistration artifacts achieved through the use of PE appears to be more beneficial than the drawback of incomplete k‐space filling. The MRI‐CFD framework presented in this study appears as a useful tool to investigate the design of MRI sequences and to stratify its different sources of errors.