Bo Li

Bo Li

Auto-generated profile, based on publicly available information

Bo Li

Department of Orthopedics, Shanghai Changzheng Hospital, Shanghai, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2025 in Neural Regeneration Research
Verified
Journal Article
Open access
SNSongzhi Ni
Songzhi Ni
KCKai Chen
Kai Chen
HWHaojue Wang
Haojue Wang
SCShenyuan Chen
Shenyuan Chen
YQYuanyu Qiu
Yuanyu Qiu
ZLZhaoshen Li
Zhaoshen Li
The bidirectional interactions of spinal cord injury, multiple sclerosis, and amyotrophic lateral sclerosis with the gut operate through a distinct gut–spinal cord axis, rather than being fully explained by the conventional gut–brain axis. The spinal cord, with its unique anatomical and physiological features, serves as a central hub of communication. The gut and spinal cord communicate through various pathways, including the immune system and the autonomic and enteric nervous systems. This review summarizes existing clinical and basic research on the relationship between gut homeostasis and spinal cord diseases. First, we present findings from epidemiological studies showing that patients with spinal cord disorders often exhibit altered gut function, which may be influenced by antibiotic exposure and environmental factors. Second, we review the key physiological and anatomical structures of the gut-spinal cord axis, including the intestinal barrier, gut microbiota, and enteric nervous system, all of which are involved in maintaining gut health, as well as sensory neurons, motor neurons, and interneurons in spinal nerve regulation. Third, we describe the roles of the three axes (microbial, immune, and neural) in bidirectional regulation and their pathological mechanisms. Moreover, vicious cycles involving these axes can exacerbate spinal cord disorders. Fourth, we outline potential biomarkers in the gut–spinal cord axis, such as uridine, hypoxanthine, and 5-methoxytryptophan. Fifth, we propose several treatment strategies with potential clinical applications, including fecal microbiota transplantation and the use of probiotics and prebiotics. Finally, this review emphasizes the gut–spinal cord axis as a promising therapeutic target, highlighting the need for multi-omics integration, longitudinal cohort studies, and individualized interventions to resolve existing debates. Overall, the recognition of the gut–spinal cord axis provides a conceptual shift that extends beyond the gut–brain framework.

1 June 2025 in APL Materials
Verified
Journal Article
Open access
ZZZhirui Zhu
Zhirui Zhu
KMKaixuan Ma
Kaixuan Ma
TYTao Yuan
Tao Yuan
BLBo Li
Bo Li
LLLiangle Liu
Liangle Liu
YBYushu Bai
Yushu Bai
Spinal cord injury (SCI) is a severe condition of the central nervous system that leads to significant functional impairments and imposes heavy socioeconomic burdens. Despite recent advancements, traditional treatments remain limited in terms of efficacy and are often associated with complications. Emerging therapies, including stem cell technologies and biomaterials, have shown promise in addressing the challenges associated with SCI recovery. Among these, hydrogels have gained considerable attention, owing to their excellent biocompatibility and adaptability, in addition to their ability to provide an optimal repair microenvironment. Importantly, hydrogels can serve as scaffolds for cell growth, drug delivery systems, or tools for modulating inflammatory responses and oxidative stress. This review comprehensively examines hydrogel-based therapies for the treatment of SCI, focusing on the mechanisms underlying secondary injury. The preparation of hydrogels and their application in promoting nerve regeneration, reducing scar formation, and mitigating oxidative damage are also presented. Furthermore, this review highlights the potential of hydrogels to facilitate macrophage polarization, increase the viability of stem cells, and enhance drug delivery precision. Despite these advancements, challenges remain, including optimization of material properties and achievement of targeted interventions. Future research should focus on developing smart hydrogels that adapt to the SCI microenvironment, investigate the integration of gene and physical therapies, and elucidate the molecular pathways involved in hydrogel-mediated regeneration. With continued innovation, hydrogels hold transformative potential in SCI treatment, being promising for improved functional recovery and patient outcomes.

22 September 2023 in Orthopaedic Surgery
Verified
Journal Article
Open access
XZXiao Zhai
Xiao Zhai
BLBo Li
Bo Li
KCKai Chen
Kai Chen
ZCZiqiang Chen
Ziqiang Chen
JSJie Shao
Jie Shao
MLMing Li
Ming Li
Objective: Improving accuracy and safety of pedicle screw placement is of great clinical importance. Electronic conductivity device (ECD) can be a promising technique with features of affordability, portability, and real‐time detection capabilities. This study aimed to validate the safety and effectiveness of a modified ECD.Methods: The ECD underwent a modification where six lamps of various colors, and it was utilized in a prospectively multicenter randomized controlled clinical trial involving 96 patients across three hospitals from June 2018 to December 2018. The trial incorporated a self‐control randomization with an equal distribution of left or right side of vertebral pedicle among two groups: the free‐hand group and the ECD group. A total of 496 pedicle screws were inserted, with 248 inserted in each group. The primary outcomes focused on the accuracy of pedicle screw placement and the frequency of intraoperative X‐rays. Meanwhile, the secondary indicator measured the time required for pedicle screw placement. Results were presented as means ± SD. Paired samples t‐test and χ2‐test were used for comparison. Furthermore, an updated review was conducted, which included studies published from 2006 onwards.Results: Baseline patient characteristics were recorded. The primary accuracy outcome revealed a 96.77% accuracy rate in the ECD group, compared to a 95.16% accuracy rate in the free‐hand group, with no significant differences noted. In contrast, ECD demonstrated a significant reduction in radiation exposure frequency when compared to the free‐hand group (1.11 ± 0.32 vs. 1.30 ± 0.53; p < 0.001), resulting in a 14.6% reduction. Moreover, ECD displayed a decrease of 30.38% in insertion time (70.88 ± 30.51 vs. 101.82 ± 54.00 s; p < 0.001). According to the results of the 21 studies, ECD has been utilized in various areas of the spine such as the atlas, thoracic and lumbar spine, as well as sacral 2‐alar‐iliac. The accuracy of ECD ranged from 85% to 100%.Conclusion: The prospectively randomized trial and the review indicate that the use of ECD presents a secure and precise approach to the placement of pedicle screws, with the added benefit of reducing both procedure time and radiation exposure.