Ji Wu

Ji Wu

Auto-generated profile, based on publicly available information

Ji Wu

Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of the Ministry of Education

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
CZChuandi Zhou
Chuandi Zhou
YLYibing Liu
Yibing Liu
JWJi Wu
Ji Wu
CZChao Zhou
Chao Zhou
Transmission towers are structurally complex, which makes it challenging to choose the right place and number of sensors for health monitoring. In this paper, optimal sensor placement of a cat-head-type transmission tower is conducted by using the Effective Independent Method (EIM) and a method is proposed for calculating the minimum number of sensors for structural health monitoring by combining EIM and Modal Assurance Criterion (MAC). The method for calculating the number of sensors prescribed in this paper derives a curve that shows the relationship between MAC value and the number of sensors. It is found that the MAC value decreases with increase in the number of sensors. When the number of sensors reaches a certain threshold, the curve tends to stabilize. Then, the number of sensors corresponding to the minimum MAC is proposed as the minimum number of sensors. Through calculation, the minimum number of sensors of the cat-head-type transmission tower is obtained. Also, the optimal sensor placement results show that the position of a large number of sensors includes the position of a smaller number of sensors.

1 October 2019
Verified
Conference Paper
Closed access
CZChuandi Zhou
Chuandi Zhou
YLYibing Liu
Yibing Liu
WTWei Teng
Wei Teng
ZMZhiyong Ma
Zhiyong Ma
JWJi Wu
Ji Wu
The air-cooled island of air-cooled thermal power unit consists of dozens of cooling units with fans and their bridges. Its structure and excitation load are complex. The health status of the air-cooled island has an impact on the safe operation of thermal power unit. In this paper, an optimal placement of health monitoring sensor for bridge structure of air-cooled island is proposed based on effective independence method. Through the finite element analysis, the main mode shapes of the bridge structure were obtained. Based on this, a given number of sensors were optimally arranged according to the Fisher information matrix. Then the optimal placement of the health monitoring sensor for the bridge structure of air-cooled island was obtained. The modal guarantee criterion was used to evaluate the placement scheme. The result shows that the sensor placement scheme can ensure the accuracy of modal identification and effectively reflect the structural characteristics of the bridge structure of the air-cooled island. The result can provide a reference for the health monitoring of the bridge structure of air-cooled island.