30 October 2012 in Hernia
30 September 2014 in Oncology Letters
Schwannoma or neurilemmoma is a well‑defined, benign tumor, which arises from neural crest cells and surrounds the nerve sheath. It is rare neoplasm that is typically found in the extremities, such as the thorax, head, neck, pelvis and rectum. Schwannoma localized to the pancreas is particularly rare and only a limited number of cases have been reported in the literature to date. The present study reports the case of a 30‑year‑old male with pancreatic schwannoma presenting with weight loss and abdominal pain. Pancreatic schwannoma was diagnosed using magnetic resonance imaging and ultrasonography‑guided biopsy, which was followed by a duodenopancreatectomy. Although pancreatic schwannomas are rare, they must be considered during the differential diagnoses of cystic pancreatic masses.
1 January 2013 in Local and Regional Anesthesia
Purpose: In this prospective, randomized, double-blind study, our aim was to compare the analgesic efficacy of the semi-blind approach of transversus abdominis plane (TAP) block with a placebo block in patients undergoing unilateral inguinal hernia repair. Methods: After receiving hospital ethical committee approval and informed patient consents, American Society of Anesthesiologists (ASA) I–III patients aged 18–80 were enrolled in the study. Standard anesthesia monitoring was applied to all patients. After premedication, spinal anesthesia was administered to all patients with 3.5 mL heavy bupivacaine at the L3-L4 subarachnoid space. Patients were randomly allocated into 2 groups. Group I (n = 32) received a placebo block with 20 mL saline, Group II (n = 32) received semi-blind TAP block with 0.25% bupivacaine in 20 mL with a blunt regional anesthesia needle into the neurofascial plane via the lumbar triangle of Petit near the midaxillary line before fascial closure. At the end of the operation, intravenous (IV) dexketoprofen was given to all patients. The verbal analog scale (VAS) was recorded at 2, 4, 6, 12, and 24 hours postoperatively. Paracetamol IV was given to patients if their VAS score > 3. A rescue analgesic of 0.05 mg/kg morphine IV was applied if VAS > 3. Total analgesic consumption and morphine requirement in 24 hours were recorded. Results: TAP block reduced VAS scores at all postoperative time points (P < 0.001). Postoperative analgesic and morphine requirement in 24 hours was significantly lower in group II (P < 0.01). Conclusion: Semi-blind TAP block provided effective analgesia, reducing total 24-hour postoperative analgesic consumption and morphine requirement in patients undergoing elective unilateral inguinal hernia repair.
1 June 2018 in Journal of Clinical Monitoring and Computing
9 May 2014 in International Journal of Surgery Case Reports
INTRODUCTION: We aimed to present the management of a patient with fistula of ileal conduit in open abdomen by intra-condoid negative pressure in conjunction with VAC Therapy and dynamic wound closure system (ABRA). PRESENTATION OF CASE: 65-Year old man with bladder cancer underwent radical cystectomy and ileal conduit operation. Fistula from uretero-ileostomy anastomosis and ileus occurred. The APACHE II score was 23, Mannheim peritoneal index score was 38 and Björck score was 3. The patient was referred to our clinic with ileus, open abdomen and fistula of ileal conduit. Patient was treated with intra-conduid negative pressure, abdominal VAC therapy and ABRA. DISCUSSION: Management of urine fistula like EAF in the OA may be extremely challenging. Especially three different treatment modalities of EAF are established in recent literature. They are isolation of the enteric effluent from OA, sealing of EAF with fibrin glue or skin flep and resection of intestine including EAF and re-anastomosis. None of these systems were convenient to our case, since urinary fistula was deeply situated in this patient with generalized peritonitis and ileus. CONCLUSION: Application of intra-conduid negative pressure in conjunction with VAC therapy and ABRA is life saving strategies to manage open abdomen with fistula of ileal conduit.
1 January 2014 in International Journal of Surgery Case Reports
INTRODUCTION: To present the management of open abdomen with colorectal fistula by application of intrarectal negative pressure system (NPS) in addition to abdominal NPS. PRESENTATION OF CASE: Twenty-year old man had a history of injuries by a close-range gunshot to the abdomen eight days ago and he had been treated by bowel repairs, resections, jejunal anastomosis and Hartman's procedure. He was referred to our center after deterioration, evisceration with open abdomen and enteric fistula in septic shock. There were edematous, fibrinous bowels and large multiple fistulas from the edematous rectal stump. APACHE II, Mannheim Peritoneal Index and Björck scores were 18, 33 and 3, respectively (expected mortality 100%). After intensive care for 5 days, he was treated by abdominal and intrarectal NPS. NPS repeated for 5 times and the fistula was recovered on day 18 completely. Fascial closure was facilitated with a dynamic abdominal closure system (ABRA) and he was discharged on day 33 uneventfully. There was no herniation and any other problem after 12 months follow-up. DISCUSSION: Management of fistula in OA can be extremely challenging. Floating stoma, fistula VAC, nipple VAC, ring and silo VAC, fistula intubation systems are used for isolation of the enteric effluent from OA. Several biologic dressings such as acellular dermal matrix, pedicled flaps have been used to seal the fistula opening with various success. Resection of the involved enteric loop and a new anastomosis of the intestine is very hard and rarely possible. In all of these reports, usually patients are left to heal with a giant hernia. In contrast to this, there is no hernia in our case during one year follow up period. CONCLUSION: Combination of intra and extra luminal negative pressure systems and ABRA is a safe and successful method to manage open abdomen with colorectal fistula.