Gouthami Chintalapani

Gouthami Chintalapani

Auto-generated profile, based on publicly available information

Gouthami Chintalapani

Siemens Medical Solutions USA, Inc., Malvern, PA 19355, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
GCGouthami Chintalapani
Gouthami Chintalapani
PCPonraj Chinnadurai
Ponraj Chinnadurai
VSVisish Srinivasan
Visish Srinivasan
SCStephen R. Chen
Stephen R. Chen
HSHashem Shaltoni
Hashem Shaltoni
PKPeter Kan
Peter Kan

10 December 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GCG. Chintalapani
G. Chintalapani
PCP. Chinnadurai
P. Chinnadurai
AMAndreas Maier
Andreas Maier
YXY. Xia
Y. Xia
SBS. Bauer
S. Bauer
MMM.E. Mawad
M.E. Mawad
BACKGROUND AND PURPOSE: Successful endovascular treatment of intracranial aneurysms requires understanding the exact relationship of implanted devices to the aneurysm, parent artery, and other branch vessels during the treatment. Intraprocedural C-arm CT imaging has been shown to provide such information. However, its repeated use is limited due to increasing radiation exposure to the patient. The goal of this study was to evaluate a new volume-of-interest C-arm CT imaging technique, which would provide device-specific information through multiple 3D acquisitions of only the region of interest, thus reducing cumulative radiation exposure to the patient. MATERIALS AND METHODS: VOI C-arm CT images were obtained in 28 patients undergoing endovascular treatment of intracranial aneurysms. VOI images were acquired with the x-ray source collimated around the deployed device, both horizontally and vertically. The images were reconstructed by using a novel prototype robust reconstruction algorithm to minimize truncation artifacts from double collimation. The reconstruction accuracy of VOI C-arm CT images was assessed quantitatively by comparing them with the full-head noncollimated images. RESULTS: Quantitative analysis showed that the quality of VOI C-arm CT images is comparable with that of the standard Feldkamp, Davis, and Kress reconstruction of noncollimated C-arm CT images (correlation coefficient = 0.96 and structural similarity index = 0.92). Furthermore, 91.5% reduction in dose-area product was achieved with VOI imaging compared with the full-head acquisition. CONCLUSIONS: VOI imaging allows multiple 3D C-arm CT acquisitions and provides information related to device expansion, parent wall apposition, and neck coverage during the procedure, with very low additional radiation exposure to the patient.

21 October 2025 in Acta Biomaterialia
Verified
Journal Article
Closed access
EVErin Marie San Valentin
Erin Marie San Valentin
JDJossana Damasco
Jossana Damasco
MBMarvin Bernardino
Marvin Bernardino
AMArchana Mishra
Archana Mishra
ABAllan John R. Barcena
Allan John R. Barcena
MMMarites Melancon
Marites Melancon

8 March 2007
Verified
Conference Paper
Closed access
PDF file
GCGouthami Chintalapani
Gouthami Chintalapani
AJAmeet K. Jain
Ameet K. Jain
RTRussell H. Taylor
Russell H. Taylor
C-arm images suffer from pose dependant distortion, which needs to be corrected for intra-operative quantitative 3D surgical guidance. Several distortion correction techniques have been proposed in the literature, the current state of art using a dense grid pattern rigidly attached to the detector. These methods become cumbersome for intra-operative use, such as 3D reconstruction, since the grid pattern interferes with patient anatomy. The primary contribution of this paper is a framework to statistically analyze the distortion pattern which enables us to study alternate intra-operative distortion correction methods. In particular, we propose a new phantom that uses very few BBs, and yet accurately corrects for distortion. The high dimensional space of distortion pattern can be effectively characterized by principal component analysis (PCA). The analysis shows that only first three eigen modes are significant and capture about 99% of the variation. Phantom experiments indicate that distortion map can be recovered up to an average accuracy of less than 0.1 mm/pixel with these three modes. With this prior statistical knowledge, a subset of BBs can be sufficient to recover the distortion map accurately. Phantom experiments indicate that as few as 15 BBs can recover distortion with average error of 0.17 mm/pixel, accuracy sufficient for most clinical applications. These BBs can be arranged on the periphery of the C-arm detector, minimizing the interference with patient anatomy and hence allowing the grid to remain attached to the detector permanently. The proposed method is fast, economical, and C-arm independent, potentially boosting the clinical viability of applications such as quantitative 3D fluoroscopic reconstruction.

1 June 2015 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
PCPonraj Chinnadurai
Ponraj Chinnadurai
GCGouthami Chintalapani
Gouthami Chintalapani
CBCarlos F. Bechara
Carlos F. Bechara
JBJean Bismuth
Jean Bismuth
ALAlan B. Lumsden
Alan B. Lumsden

11 October 2025 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
TRTatiana A. Rypinski
Tatiana A. Rypinski
RCRoberto F. Casal
Roberto F. Casal
PPParvathy S. Pillai
Parvathy S. Pillai
ADAnshuj Deva
Anshuj Deva
BSBhavin Soni
Bhavin Soni
JSJeffrey H. Siewerdsen
Jeffrey H. Siewerdsen