Ivo Furno

Ivo Furno

Auto-generated profile, based on publicly available information

Ivo Furno

École Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC) , CH-1015 Lausanne

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2012 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PRP Ricci
P Ricci
FHF D Halpern
F D Halpern
SJS Jolliet
S Jolliet
JLJ Loizu
J Loizu
AMA Mosetto
A Mosetto
CTC Theiler
C Theiler

6 February 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
IFI. Furno
I. Furno
BLB. Labit
B. Labit
MPM. Podestà
M. Podestà
AFA. Fasoli
A. Fasoli
SMS. H. Müller
S. H. Müller
JGJ. Graves
J. Graves
The mechanism for blob generation in a toroidal magnetized plasma is investigated using time-resolved measurements of two-dimensional structures of electron density, temperature, and plasma potential. The blobs are observed to form from a radially elongated structure that is sheared off by the E×B flow. The structure is generated by an interchange wave that increases in amplitude and extends radially in response to a decrease of the radial pressure scale length. The dependence of the blob amplitude upon the pressure radial scale length is discussed.

3 August 2009 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
CTC. Theiler
C. Theiler
IFI. Furno
I. Furno
PRP. Ricci
P. Ricci
AFA. Fasoli
A. Fasoli
BLB. Labit
B. Labit
GPG. Plyushchev
G. Plyushchev
The radial propagation of blobs generated from plasma instabilities is investigated in an open magnetic field line configuration. Blob cross-field velocities and sizes are obtained from internal probe measurements using pattern recognition. By varying the ion mass, the normalized vertical blob scale a˜ is scanned from a˜<1 to a˜>1. An analytical expression for the blob velocity including cross-field ion polarization currents, parallel currents to the sheath, and ion-neutral collisions is derived and shows good quantitative agreement with the experimental data. In agreement with previous theoretical studies, this scaling shows that, for a˜<1, the blob velocity is limited by cross-field ion polarization currents, while for a˜>1 it is limited by parallel currents to the sheath.

20 June 2007 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
BLB. Labit
B. Labit
IFI. Furno
I. Furno
AFA. Fasoli
A. Fasoli
ADA. Diallo
A. Diallo
SMS. H. Müller
S. H. Müller
FPF. M. Poli
F. M. Poli
A unique parabolic relation is observed to link skewness and kurtosis of around ten thousand density fluctuation signals, measured over the whole cross section of a toroidal magnetized plasma for a broad range of experimental conditions. All the probability density functions of the measured signals, including those characterized by a negative skewness, are universally described by a special case of the Beta distribution. Fluctuations in the drift-interchange frequency range are necessary and sufficient to assure that probability density functions can be described by this specific Beta distribution.

2 March 2009 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
FPF Piras
F Piras
SCS Coda
S Coda
IFI Furno
I Furno
JMJ-M Moret
J-M Moret
RPR A Pitts
R A Pitts
CZC Zucca
C Zucca

10 April 2000 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
OSO. Sauter
O. Sauter
MHM. A. Henderson
M. A. Henderson
FHF. Hofmann
F. Hofmann
TGT. Goodman
T. Goodman
SAS. Alberti
S. Alberti
HWH. Weisen
H. Weisen
A steady-state, fully noninductive plasma current has been sustained for the first time in a tokamak using electron cyclotron current drive only. In this discharge, 123 kA of current have been sustained for the entire gyrotron pulse duration of 2 s. Careful distribution across the plasma minor radius of the power deposited from three 0.5-MW gyrotrons was essential for reaching steady-state conditions. With central current drive, up to 153 kA of current have been fully replaced transiently for 100 ms. The noninductive scenario is confirmed by the ability to recharge the Ohmic transformer. The dependence of the current drive efficiency on the minor radius is also demonstrated.