Peter Oelsner

Peter Oelsner

Auto-generated profile, based on publicly available information

Peter Oelsner

Deutscher Wetterdienst/GRUAN Lead Center, Lindenberg, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2018 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
SBSimone Brunamonti
Simone Brunamonti
TJTeresa Jorge
Teresa Jorge
POPeter Oelsner
Peter Oelsner
SHSreeharsha Hanumanthu
Sreeharsha Hanumanthu
BSBhupendra Bahadur Singh
Bhupendra Bahadur Singh
TPThomas Peter
Thomas Peter
The Asian summer monsoon anticyclone (ASMA) is a major meteorological system of the upper troposphere–lower stratosphere (UTLS) during boreal summer. It is known to contain enhanced tropospheric trace gases and aerosols, due to rapid lifting from the boundary layer by deep convection and subsequent horizontal confinement. Given its dynamical structure, the ASMA represents an efficient pathway for the transport of pollutants to the global stratosphere. A detailed understanding of the thermal structure and processes in the ASMA requires accurate in situ measurements. Within the StratoClim project we performed state-of-the-art balloon-borne measurements of temperature, water vapor, ozone and aerosol backscatter from two stations on the southern slopes of the Himalayas. In total, 63 balloon soundings were conducted during two extensive monsoon-season campaigns, in August 2016 in Nainital, India (29.4 ∘ N, 79.5 ∘ E), and in July–August 2017 in Dhulikhel, Nepal (27.6 ∘ N, 85.5 ∘ E); one shorter post-monsoon campaign was also carried out in November 2016 in Nainital. These measurements provide unprecedented insights into the UTLS thermal structure, the vertical distributions of water vapor, ozone and aerosols, cirrus cloud properties and interannual variability in the ASMA. Here we provide an overview of all of the data collected during the three campaign periods, with focus on the UTLS region and the monsoon season. We analyze the vertical structure of the ASMA in terms of significant levels and layers, identified from the temperature and potential temperature lapse rates and Lagrangian backward trajectories, which provides a framework for relating the measurements to local thermodynamic properties and the large-scale anticyclonic flow. Both the monsoon-season campaigns show evidence of deep convection and confinement extending up to 1.5–2 km above the cold-point tropopause (CPT), yielding a body of air with high water vapor and low ozone which is prone to being lifted further and mixed into the free stratosphere. Enhanced aerosol backscatter also reveals the signature of the Asian tropopause aerosol layer (ATAL) over the same region of altitudes. The Dhulikhel 2017 campaign was characterized by a 5 K colder CPT on average than in Nainital 2016 and a local water vapor maximum in the confined lower stratosphere, about 1 km above the CPT. Data assessment and modeling studies are currently ongoing with the aim of fully exploring this dataset and its implications with respect to stratospheric moistening via the ASMA system and related processes.

26 February 2021 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
WSWolfgang Steinbrecht
Wolfgang Steinbrecht
DKDagmar Kubistin
Dagmar Kubistin
CPChristian Plass‐Dülmer
Christian Plass‐Dülmer
JDJonathan Davies
Jonathan Davies
DTDavid Tarasick
David Tarasick
OCOwen R. Cooper
Owen R. Cooper
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (≈4 nmol/mol) below the 2000–2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere contributed less than one‐quarter of the observed tropospheric anomaly. The observed anomaly is consistent with recent chemistry‐climate model simulations, which assume emissions reductions similar to those caused by the COVID‐19 crisis. COVID‐19 related emissions reductions appear to be the major cause for the observed reduced free tropospheric ozone in 2020.

11 July 2019 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SBS. Brunamonti
S. Brunamonti
LFL. Füzér
L. Füzér
TJT. Jorge
T. Jorge
YPY. Poltera
Y. Poltera
POP. Oelsner
P. Oelsner
TPT. Peter
T. Peter
Water vapor (H2O) is the strongest greenhouse gas in our atmosphere. Hence, accurate measurements and a correct representation in global models of H2O in the upper troposphere/lower stratosphere (UTLS) are important for understanding and projecting climate. Here we compare balloon‐borne measurements of UTLS H2O, performed by cryogenic frostpoint hygrometers (CFH) and meteorological radiosondes (Vaisala RS41) during two intensive field campaigns in the Asian summer monsoon anticyclone region, with humidity data from three products of the European Centre for Medium‐range Weather Forecasts (ECMWF): operational analysis and forecast (termed OPERA), ERA‐Interim reanalysis, and the newly released ERA5 reanalysis. Taking CFH as a reference, we show that OPERA and ERA5 provide a more accurate representation of UTLS H2O than ERA‐Interim. In particular, OPERA and ERA5 similarly overestimate H2O mixing ratios by on average 0.7–0.8 ppmv (14–15%) and 0.7–0.9 ppmv (15–17%) at pressures 60–100 hPa, respectively, and both provide a good representation of the observed vertical distribution (including fine structures) and natural variability of UTLS H2O. In contrast, ERA‐Interim underestimates UTLS H2O by 0.6–1.7 ppmv (14–30%), and it fails to capture relevant features of the vertical distribution of UTLS H2O. At pressures (p) lower than 60 hPa, all three ECMWF products are in good agreement with CFH. Humidity measurements by RS41 show an average dry bias of 0.1–0.5 ppmv (3–9%) compared to CFH for 60–100 hPa, and a moist bias increasing with altitude for p < 60 hPa, exceeding 100% for p < 40 hPa.

1 March 2025 in Earth and Space Science
Verified
Journal Article
Open access
WSWolfgang Steinbrecht
Wolfgang Steinbrecht
VVVoltaire Velazco
Voltaire Velazco
RDR. Dirksen
R. Dirksen
LDLionel Doppler
Lionel Doppler
POP. Oelsner
P. Oelsner
AHAlain Hauchecorne
Alain Hauchecorne
Routine ground‐based measurements of total ozone column (TOC), as well as ozone profile soundings started in the late 1960s in Germany. The resulting ozone and temperature records at Hohenpeissenberg and Berlin/Potsdam/Lindenberg show long‐term changes similar to other stations in Central Europe, and to the changes seen globally. Following the increase of ozone depleting substances (ODS), stratospheric ozone has declined from the 1960s until the 1990s. Since about 2000, ozone has leveled or slightly increased, consistent with declining amounts of ODS. The stratosphere has been cooling and the troposphere has been warming, in agreement with general expectations due to increasing greenhouse gas concentrations. The clearest signs of recovering ozone are seen around 40 km altitude. Two factors contribute to this increase: the decrease of stratospheric chlorine loading and cooling of the upper stratosphere, which slows gas‐phase ozone destruction cycles, and enhances the ter‐molecular reaction producing ozone. Tropospheric ozone has increased substantially from the 1960s to the early 1990s. Since then, it has remained more or less constant, on a level higher compared to the 1960 and 1970s. Particularly low tropospheric ozone was observed in 2020, due to reduced precursor emissions during the COVID‐19 related lockdowns. The atmospheric concentrations of greenhouse gases will likely continue to rise, while the concentrations of ozone depleting substances are expected to slowly decline. To see how the atmosphere responds, and to help understand future changes, continued monitoring will be required for many years to come, both over Germany and worldwide.

14 January 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
TJTeresa Jorge
Teresa Jorge
SBSimone Brunamonti
Simone Brunamonti
YPYann Poltera
Yann Poltera
FWFrank G. Wienhold
Frank G. Wienhold
BLBei P. Luo
Bei P. Luo
TPThomas Peter
Thomas Peter
Balloon-borne water vapour measurements in the upper troposphere and lower stratosphere (UTLS) by means of frost point hygrometers provide important information on air chemistry and climate. However, the risk of contamination from sublimating hydrometeors collected by the intake tube may render these measurements unusable, particularly after crossing low clouds containing supercooled droplets. A large set of (sub)tropical measurements during the 2016–2017 StratoClim balloon campaigns at the southern slopes of the Himalayas allows us to perform an in-depth analysis of this type of contamination. We investigate the efficiency of wall contact and freezing of supercooled droplets in the intake tube and the subsequent sublimation in the UTLS using computational fluid dynamics (CFD). We find that the airflow can enter the intake tube with impact angles up to 60∘, owing to the pendulum motion of the payload. Supercooled droplets with radii > 70 µm, as they frequently occur in mid-tropospheric clouds, typically undergo contact freezing when entering the intake tube, whereas only about 50 % of droplets with 10 µm radius freeze, and droplets < 5 µm radius mostly avoid contact. According to CFD, sublimation of water from an icy intake can account for the occasionally observed unrealistically high water vapour mixing ratios (χH2O > 100 ppmv) in the stratosphere. Furthermore, we use CFD to differentiate between stratospheric water vapour contamination by an icy intake tube and contamination caused by outgassing from the balloon and payload, revealing that the latter starts playing a role only during ascent at high altitudes (p < 20 hPa).

8 December 2020 in ESS Open Archive
Verified
Preprint
Open access
WSWolfgang Steinbrecht
Wolfgang Steinbrecht
DKDagmar Kubistin
Dagmar Kubistin
CPChristian Plass-Dulmer
Christian Plass-Dulmer
DTDavid Tarasick
David Tarasick
JDJonathan Davies
Jonathan Davies
ATAnne M. Thompson
Anne M. Thompson
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (~4 ppbv) below the 2000 to 2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition re-analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere has contributed less than one quarter to the observed tropospheric anomaly. The observed anomaly is consistent with two recent model simulations, which assume emission reductions similar to those caused by the COVID-19 crisis. COVID-19 related emission reductions appear to be the major cause for the observed low free tropospheric ozone in 2020.