Silicone and polyurethane are biocompatible materials used for the manufacture of implantable catheters, but are known to induce drug loss by sorption, causing potentially important clinical consequences. Despite this, their impact on the drugs infused through them is rarely studied, or they are studied individually and not part of a complete infusion setup. The aim of this work was to experimentally investigate the drug loss that these devices can cause, on their own and within a complete infusion setup. Paracetamol, diazepam, and insulin were chosen as models to assess drug sorption. Four commonly used silicone and polyurethane catheters were studied independently and as part of two different setups composed of a syringe, an extension set, and silicone or polyurethane implantable catheter. Simulated infusion through the catheter alone or through the complete setup were tested, at flowrates of 1 mL/h and 10 mL/h. Drug concentrations were monitored by liquid chromatography, and the silicone and polyurethane materials were characterized by ATR-IR spectroscopy and Zeta surface potential measurements. The losses observed with the complete setups followed the same trend as the losses induced individually by the most sorptive device of the setup. With the complete setups, no loss of paracetamol was observed, but diazepam and insulin maximum losses were respectively of 96.4 ± 0.9% and 54.0 ± 5.6%, when using a polyurethane catheter. Overall, catheters were shown to be the cause of some extremely high drug losses that could not be countered by optimizing the extension set in the setup.
24 October 2010 in International Journal of Photoenergy
Carbazolic copolymers have been developed to be used in reversible holographic recording. This paper describes a complete analysis, from synthesis of the material to its applications, together with the corresponding characterizations. The investigated materials were photosensitive copolymers obtained from carbazolylalkylmethacrylates (CEM) and octylmethacrylate (OMA). A detailed investigation was undertaken involving infrared spectroscopy and NMR techniques,1H,13C, COSY, and HSQC, in order to establish the chemical structure and the composition of the copolymers. Holographic recording characteristics were investigated with one- and two-layer photothermoplastic carriers. The two-layer carrier contains separate photosensitive and thermoplastic layers and gives the best holographic response. The surface of microstructured samples has been characterized by atomic force microscopy analysis. It is shown that via a photothermoplastic recording process, it is possible to record and read holograms practically in real time (~3 s) with a diffraction efficiency of 10% and a spatial resolution higher than 1000 .
Short contacts between medical devices and medications that they contain can cause drug sorption or leaching of unwanted compounds which can have clinical consequences. However, the parameters that govern these interactions are still incompletely understood. The objectives of this study were to evaluate the impact of the formulation parameters on migration of 2,4 Di-tert-butylphenol (2,4 DTBP) and sorption of tacrolimus (TAC) in a model micellar ophthalmic drug formulation which is known to interact with silicone elastomers. A design of experiments was established to evaluate the impact of the formulation parameters on 2,4 DTBP leaching and tacrolimus sorption by varying the initial concentrations of TAC (0.04; 0.2 and 1 mg/mL), polyoxyethylenated castor oil (KEL) (32; 80 and 200 mg/mL) and ethanol absolute (EtOH) (10 and 100 mg/mL), at 5°C and 25°C, during static contact between various formulations and silicone valves obtained from an ophthalmic multidose delivery device. Concentrations of 2,4 DTBP and TAC were monitored by liquid chromatography coupled with an UV–visible detector. Under the conditions studied, the amount of 2,4 DTBP leaching out increased during contact with the silicone valve, with increasing TAC concentration being quite interestingly the main factor decreasing its ability to leach out, whilst ethanol increased its leachability. The silicone valve did not cause any significant decrease of TAC concentrations over the duration of the study, regardless of the concentrations of KEL, EtOH, or temperature. This study showed the impact of formulation on the leaching of 2,4 DTBP from a silicone component. Graphical Abstract
The study of extractable chemicals is used to evaluate whether a medical device contains harmful substances susceptible to migrate and contaminate the patients they are used in. The analysis of the biomaterial itself after extraction is often left aside. The aim of this study is to characterise and investigate whether any changes occur during the extraction process. Two biomaterials (thermoplastic polyurethane (TPU) and silicone from intravenous catheters) were studied after extraction, using acetone and hexane. To study the surface, we used scanning electron microscopy (morphological aspect), energy dispersive spectroscopy and x-ray photoelectron spectroscopy (atomic composition), infrared spectroscopy (molecular composition). Thermogravimetric analysis and differential scanning calorimetry were used for in-depth characterisation. It was found that the extreme surface consisted of the polymer and external contaminants or organic products that had migrated from the core to the surface. Analysis of TPU showed that acetone was a suitable swelling agent. No significant change in the material was observed after hexane maceration. For silicone, the situation was reversed. We concluded that the solvents used were well suited for an extractables study of these two materials, and gained understanding of the phenomena that could lead to leaching during their medical use.
6 September 2026 in International Journal of Pharmaceutics
The use of automated injectors for the administration of radiopharmaceuticals limits staff exposure and optimises the dose administered to patients, but many of these devices are only validated for a limited number of radiopharmaceuticals. The objectives of this study were to investigate the physicochemical phenomena occurring during the manipulation of fluorinated radiopharmaceuticals when in contact with injector tubings and to quantify and qualify the interactions between the radiopharmaceuticals and the tubing materials. For six of the radiopharmaceuticals tested, the measured doses reached 97.64 ± 0.24% of the programmed dose. These results indicate an absence of sorption phenomena and validate their use on the injector. In contrast, the three most lipophilic molecules caused the injector to malfunction, resulting in significant residual activity in the tubing of up to 67%. These results were confirmed by activimeter measurements and positron emission tomography images. from electronic microscopy results showed an alteration of the inner surface of the tubings that came into contact with lipophilic radiopharmaceuticals; however, this modification did not drastically alter the surface Zeta potential. Infrared spectroscopy confirmed the composition of the tubings as being plasticized polyvinyl chloride (PVCp), and plasticizer identification and quantification showed the presence of di-(2-ethylhexyl) adipate (reaching 37.5%) and di-(2-ethylhexyl) phthalate (more than 20%). A clear improvement was observed when co-extruded polyethylene / PVPp tubings were used. Unlike lipophilic radiopharmaceuticals, which exhibit sorption behaviour dependent on the presence of plasticizers, the tested hydrophilic radiopharmaceuticals demonstrated minimal interaction with PVCp tubing and can be reliably administered using the automated injector.