The deterioration of materials due to the effect of atmospheric pollution generates a cost to society because the maintenance and replacement of degraded materials. Galvanised steel is used in electrical industry to build electrical transmission towers (ETT). The objective of the study was to estimate the annual maintenance cost of galvanised steel used in the construction of ETT. The maintenance cost for galvanised steel was estimated considering the cost of the material surface area and the difference between the maintenance interval of clean and contaminated areas. Maps of intervals and maintenance costs were obtained for galvanised steel (85 and 100 µm), which are the thicknesses regulated in Mexico for ETT. In addition, an ArcGis geographic information system was used for a spatial representation of data from the anthropogenic environment. The mapping of areas at risk of corrosion shows that in the northwest zone, ETT presents the highest maintenance costs for the year 2019. For galvanised steel thicknesses of 85 and 100 µm, there are annual costs of, respectively, 8.68 and 10.16 USD/m2.
BACKGROUND AND OBJECTIVES: Atmospheric zinc corrosion in the Mexico City Metropolitan area has long been attributed mainly to the effect of pollutants such as sulfur dioxide. There are changes in the urban atmosphere's chemical composition due to the implementation of air quality policies focused on reducing the emission of sulfur dioxide and other pollutants. This study's objectives were to estimate and map the contribution of nitric acid on zinc's atmospheric corrosion process. METHODS: The impact of nitric acid on zinc is feasible to estimate using a function for a multi-pollutant situation. This function contemplates the sum of two contributions: one of nitric acid and another that includes sulfuric acid and climatic parameters. The multi-pollutant function is suitable to apply in areas without the strong influence of chlorides and tropical and subtropical climates, comparable to the Mexico City Metropolitan area. FINDINGS: The results showed that spatial and temporal estimation of corrosion rates in grams per square meter of zinc was made for 2015-2019, using data modeling in a geographic information system. The maps of corrosion rates allowed us to visualize that, in general, the "southwest" zone has the most significant effects and that the lowest corrosion rates were presented in 2019 as an outcome of the implementation of air quality programs. Furthermore, a contribution of nitric acid up to 32% to the zinc corrosion rate was estimated. CONCLUSION: The construction of corrosion rate maps provides a spatial and temporal estimate that allows visualizing areas where zinc materials are at risk corrosion due to the dispersion of atmospheric pollutants and climatic parameters. Likewise, it can represent a decision-making tool for the implementation of atmospheric corrosion studies of materials. (C) 2021 GJESM. All rights reserved.
30 September 2026 in Avances en Ciencia e Ingeniería
Se construyen mapas híbridos de índices de Aire y Salud (IAS) de partículas en suspensión menores a 2.5 micrómetros (PM2.5), de mediciones de la Red Estatal de Monitoreo Automática (REMA) y estimaciones basadas en datos satelitales del Servicio de Monitoreo Atmosférico de Copernicus (CAMS). Se estima el IAS para PM2.5 en zonas donde la REMA no tienen alcance empleando la información de CAMS, para describir la contaminación atmosférica en la zona de estudio. Se emplea el sistema de información geográfica ArcGis para representar espacial y temporalmente los mapas de IAS promedio mensual del año 2021. Se observa que durante la temporada fría-seca se representa el mayor riesgo a la salud, donde la zona suroeste en el mes diciembre implican un nivel de riesgo muy alto. Los IAS en las estaciones CCA, DICA y UTP estimados mediante CAMS y utilizados en la modelación con ArcGIS contribuyen en la predicción de eventos de riesgo moderado de IAS de PM2.5. Esto ocurre en las temporadas cálida-seca y fría-seca en una escala regional durante el año 2021.
Air quality in the Metropolitan Zone of the Valley of Puebla has shown in previous years that suspended particles less than 10 micrometers (PM10) and less than 2.5 micrometers (PM2.5) present a health risk. The automatic air quality monitoring system in Puebla measures PM10 and PM2.5 at five stations in the Puebla and Coronango municipalities. These measurements allow for the determination of the Air and Health Index according to the NOM-172-SEMARNAT-2019 standard for these pollutants. The advancement of satellite monitoring techniques represents an opportunity for air quality management where terrestrial measurements are scarce. However, to obtain reliable data, it is necessary to validate the satellite data with ground measurements from georeferenced monitoring stations. The operational implementation forecast of the Copernicus Atmospheric Monitoring Service (CAMS) allows for conducting out atmospheric pollution exploration processes. An analysis of this forecast data determined that the Persistence forecast is better than the CAMS forecast overall for both PM10 and PM2.5. However, the CAMS forecast can be employment for a preliminary evaluation in the prediction of PM2.5 due to the success in the comparison criteria of the dichotomous statistics ACCURACY, POD, FAR, POFD, SR, TS, ETS, HSS and ORSS.